OPA333AIDR
Product Specifications
OPA333AIDR
Texas Instruments — Power Management & Signal Chain
Product Overview
The OPA333AIDR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
OPA333AIDR: zero-drift CMOS operational amplifier with 10 microvolt offset and 17 microamps of supply current
OPA333AIDR is a zero-drift CMOS operational amplifier in an 8-pin SOIC that holds 10 microvolts of offset on 17 microamps from a 1.8 V supply in a SOIC body of 8 pins. The AIDR suffix is the 8-pin SOIC body supplied on a 2500 piece reel. The offset window is 2 microvolts typical and 10 microvolts maximum, drift is 0.02 microvolts per degree typical and 0.05 maximum, supply current is 17 microamps, and the input common mode reaches 100 millivolts beyond either rail, which is what makes a 1.8 V single supply usable for a ground referenced bridge.
Order code and package
| Order code | OPA333AIDR |
| Function | zero-drift CMOS operational amplifier, rail-to-rail input and output |
| Package | SOIC, 8 pins, body code D, 2500 piece reel |
| Supply range | 1.8 V to 5.5 V |
| Supply current | 17 microamps |
| Gain bandwidth | 350 kHz with a 100 picofarad load |
| Slew rate | 0.16 volts per microsecond |
| Offset | 2 microvolts typical, 10 microvolts maximum |
| Drift | 0.02 microvolts per degree typical, 0.05 microvolts per degree maximum |
| Input common mode | 100 millivolts beyond either rail |
| Startup | about 100 microseconds to reach the specified offset after power up |
| Datasheet | SBOS351E, revision of December 2015 |
Electrical parameters that decide the application
| Power-supply rejection | 1 microvolt per volt typical, 5 microvolts per volt maximum |
| Common-mode rejection | 106 dB minimum, 130 dB typical |
| Input bias current | 70 picoamps typical, 200 picoamps maximum at 25 C, 150 picoamps typical over temperature |
| Input offset current | 140 picoamps typical, 400 picoamps maximum |
| Noise from 0.01 to 1 Hz | 0.3 microvolts peak to peak |
| Noise from 0.1 to 10 Hz | 1.1 microvolts peak to peak |
| Current noise | 100 femtoamps per root hertz at 10 Hz |
| Input capacitance | 2 picofarads differential, 4 picofarads common mode |
| Short-circuit current | 5 milliamps |
Points to check before this part goes on a BOM
10 microvolts is 0.13 of a bit on a 16 bit converter at 5 V, so the amplifier stops being the accuracy limit entirely. Drift of 0.05 microvolts per degree over 165 degrees is 8 microvolts, still below the room temperature offset, so a channel calibrated once holds its reading to within a fraction of a bit over the whole industrial and automotive range. The remaining errors are the reference, the resistors and the thermocouples in the joints.
17 microamps at 3.3 V is 56 microwatts and 149 milliamp hours over a year, which is what makes a coin cell product possible. The same 17 microamps is also the reason the bandwidth is 350 kHz: the amplifier spends its current on the chopping loop and the calibration rather than on transconductance, so a 100 kHz signal at unity gain is already outside the small signal bandwidth.
The 0.3 microvolts peak to peak from 0.01 to 1 Hz is the figure that matters for a scale or a pressure sensor that updates once a second. At 16 bits on a 5 V range a bit is 76 microvolts, so the low frequency noise is four thousandths of a bit and the resolution is set by the sensor and the reference. Above 1 Hz the density curve rises to the 1.1 microvolts peak to peak quoted from 0.1 to 10 Hz.
The input goes 100 millivolts beyond both rails, which allows a bridge or a shunt to sit at the negative rail without a charge pump. It also means the input pair changes state as the common mode crosses between the two input stages, and the datasheet quantifies the resulting step rather than hiding it: the rejection falls to 80 dB in the crossover region against 130 dB typical outside it, so a signal that sits exactly at mid-rail sees a small nonlinearity.
Startup is a real specification: the part needs about 100 microseconds after power is applied before the offset meets the 10 microvolt window. A system that powers the amplifier, converts one reading 20 microseconds later and goes back to sleep will read the uncalibrated offset, and on a duty cycled node that is the difference between a working channel and an intermittent one. The 100 microseconds belongs in the wake up timing, not in the datasheet margin.
200 picoamps of maximum bias current through a 1 megohm source is 200 microvolts, which is twenty times the offset and therefore the dominant error on a high impedance sensor. At 10 kilohms the same current produces 2 microvolts, which is the offset itself. The practical source limit for this part is somewhere between those two, at about 100 kilohms where the bias error equals the offset window.
Where this order code fits
Coin cell and energy harvesting nodes, portable medical strips, gas and pressure sensors and precision low-side current sense stages use this part because 17 microamps and 10 microvolts rarely appear in the same order code. The 350 kHz bandwidth suits channels that convert a few thousand times a second. Boards comparing it with a neighbouring part start from our Amplifier Cross Reference page, and boards replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
Does the OPA333 need time to settle its offset after power up? Yes, about 100 microseconds before the offset meets the specified window. A duty cycled node has to allow for that delay before the first conversion.
How does the input behave at the supply rails? The common mode reaches 100 millivolts beyond either rail, but the input stage changes over inside that range and the common-mode rejection drops to 80 dB in the transition band against 130 dB typical outside it.
Is this part suitable for a 1.8 V single supply bridge? Yes. The supply floor is 1.8 V, the input goes 100 millivolts past both rails and the output is rail to rail, so a ground referenced bridge with a 1.8 V excitation is inside the specified window.
SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the Obsolete RF Part Replacement page sets out the checks that keep a substitute from failing on the bench.