Contact Us

LM293D

Brand: Texas Instruments
Texas Instruments LM293D is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LM293D — Power Management & Signal Chain | Superb Automation

LM293D

Texas Instruments — Power Management & Signal Chain

Product Overview

The LM293D from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

LM293D: the plain dual comparator in a tube, and an orderable row the addendum has withdrawn

LM293D is the plain grade of the dual differential comparator in the eight pin small outline body, supplied in a tube, from minus 25 to plus 85 degrees. The plain grade means what it says: 2 millivolts typical and 5 millivolts maximum at 25 degrees, widening to 9 millivolts over the window, against 2 and 4 on the A sort.

The row itself is the news. The orderable addendum attached to the current revision of the family document prints LM293D with the status obsolete, while LM293DR, LM293ADR and LM293AD are printed as active. A tube code that a bench has used for years can therefore be unavailable while the reel of the same die is in stock, which is a purchasing problem dressed up as a shortage.

What the addendum prints and what it does not

The table below is what the document says about this string and its neighbours. The electrical rows are the same on all four, apart from the A sort offset, and the carrier and the status are the only things that separate them.

Orderable codeLM293D
Status on the current addendumobsolete
Comparators per body2, independent
BodySOIC, 8 pins
Carriertube
Offset gradeplain, 2 millivolts typical
Offset maximum at 25 degrees5 millivolts
Offset maximum over the window9 millivolts
Temperature windowminus 25 to plus 85 degrees
Active siblingsLM293DR, LM293AD, LM293ADR
Supply voltage2 to 36 volts
Outputopen collector, 16 milliamps typical sink at 1.5 volts
Response time1.3 microseconds typical

The electrical rows, unchanged by the status

Nothing in the silicon changed on the day the row was withdrawn. The input range still reaches ground and stops 1.5 volts below the positive rail at room temperature, 2 volts over the window. Gain is still 50 volts per millivolt minimum, the output still sinks 16 milliamps and drops 130 millivolts at 4 milliamps, and the supply current is still 0.45 milliamps typical at 5 volts.

That is what makes the obsolete flag a paperwork event rather than a technical one. A board that carries LM293D will work with LM293DR from the same body, on the same feeder position if a reel is used, or from a cut length if the build is small. The bill of materials has to be revised, and the customer has to approve the revision if the part is on a controlled drawing.

The one thing that can genuinely bite is the handling difference between a tube and a reel. A line that has no reel feeder, or a build that is too small to justify a full reel, has to buy cut tape, and cut tape changes the count and the labelling rather than the part.

Three routes when the tube code is gone

The first route is remaining stock. Brokers and distributors hold obsolete rows for years, and the quantity that exists is whatever was bought before the withdrawal. That is fine for a two year bridge and useless for a ten year programme, and it needs a date on it.

The second route is a carrier change to the reel code. This is the cleanest on a controlled programme because the die, body and electrical table are identical and only the packaging line of the drawing changes. It needs the reel feeder and a count that reconciles.

The third route is a grade change to the A sort, which is a technical improvement and a drawing change at the same time. It is worth taking when the threshold budget is tight, and it is overkill when the only problem is that the tube code cannot be bought.

Our last time buy and LTB planning page works through the arithmetic of the first route, and the obsolete part cross reference hub is where the family notes sit when a row is withdrawn. The component obsolescence management page covers the notification side, which is how the row should have been caught before it reached a build.

Reading a withdrawal notice properly

A withdrawal notice on a comparator of this age is rarely about the die. It is about a carrier, a finish or an assembly site, and the notice usually names the replacement row in the same document. The question to ask is which of the four strings has the same die, the same body and the same window, and whether the difference is a carrier, a material code or an offset sort.

That last distinction is the one that gets missed. A replacement that differs only in carrier is a packaging change. A replacement that differs in material code is a declaration change. A replacement that differs in offset sort is an electrical change even though the pinout is identical, and it needs a threshold budget rather than a purchasing decision.

Keeping the four strings apart in the bill of materials is the simplest defence. One line per approved code, with the carrier and the sort named in the description, means a withdrawal notice maps onto exactly one line and the replacement is obvious.

Last time buy arithmetic

A bridge buy on a withdrawn tube code is three numbers and a date. Annual usage, the quantity still available at a known date code, and the date the drawing revision will be approved. If the stock covers usage until the revision plus a quarter, the buy is safe. If it covers less, the revision date drives the order rather than the price.

Two costs are easy to forget. Storage of a bridge buy sits on the balance sheet for years, and a tube code bought in volume is a stock of parts that has to be counted, stored and re-counted every audit. The second cost is the last reel that arrives with a date code the customer will not accept, which is a write off rather than a saving.

Reading the customer drawing

An approved drawing usually names one orderable code and one vendor, and sometimes names an approved alternate. When the named row is withdrawn, the drawing is what has to change, and the change is a revision with a form fit function statement attached rather than a purchasing substitution.

The statement itself is short on this family. Same body, same pin count, same window, same electrical table, carrier change from tube to reel. Attach the addendum page that prints both rows and the statement writes itself, which is why the paperwork usually takes less time than the search for stock.

The one case that needs more than a carrier statement is a move to the A sort. That is an electrical change, and the threshold budget has to be rechecked before the drawing is revised, even though the footprint is unchanged.

Two rules keep the file clean while the revision is in review. Do not ship the replacement against the old drawing without a written note, and do not leave both strings active on the bill of materials after the revision is approved. The first protects the audit trail, the second protects the buyer from ordering the row that can no longer be filled.

Questions that come with this code

Is the part still made? The die and the reel codes are still active. The tube row specifically is printed obsolete, so the answer depends on which line of the addendum is being read.

Can LM293DR be used in place of LM293D? Yes, the die and the electrical table are the same and the difference is the carrier. On a controlled drawing the change is a revision rather than a new circuit.

Does the obsolete status affect the moisture rating? No, the body keeps its rating, and the handling rule is unchanged.

What if the customer insists on the exact string? Then the buy is remaining stock, with a date on the plan, and the drawing revision should start at the same time rather than after the stock runs out.