Contact Us

ISO7341FCDWR

Brand: Texas Instruments
Texas Instruments ISO7341FCDWR is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO7341FCDWR — Power Management & Signal Chain | Superb Automation

ISO7341FCDWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO7341FCDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO7341FCDWR: the same quad with the fail-safe output high instead of low

ISO7341FCDWR is the FC code of the four channel isolator in the sixteen pin wide body SOIC on a large reel of 2000: three channels forward, one back, 3000 volts of withstand, 25 megabits per second, and a default output that goes high when the input side loses power. That default is the only difference from the C code beside it on the same reel size.

The FC code is slightly slower because the default state has to be detected and enforced: 22 nanoseconds typical and 35 maximum at 25 degrees against 20 and 31 for the C code, and 66 nanoseconds at the limit against 58. At 25 megabits a bit is 40 nanoseconds, so both codes stay inside the margin a synchronous link needs.

ISO7341FCDWR as the vendor document publishes it

Channels4, three forward and one back
Signaling rate25 megabits per second
Propagation delay, C code20 nanoseconds typical, 31 maximum
Propagation delay, FC code22 nanoseconds typical, 35 maximum
Propagation delay over temperature58 nanoseconds maximum on the C code, 66 on the FC code
Channel to channel skew2.5 nanoseconds maximum
Part to part skew23 nanoseconds maximum
Enable and disable delay7 to 13 nanoseconds
Common mode transient immunity25 kilovolts per microsecond minimum
Supply3 to 5.5 volts per side
Withstand isolation3000 volts root mean square for 60 seconds
Maximum repetitive isolation1414 volts peak
Maximum transient isolation4242 volts peak
Clearance and creepagegreater than 8 millimetres
Temperature rangeminus 40 to plus 125 degrees
Package16 pins, wide body SOIC DW
Catalogue codeISO7341FCDWR
Vendor statusactive
Default outputhigh on loss of input power
Carrierlarge reel of 2000
Moisture levellevel 2, 260 degrees, one year floor life

Three thousand volts, and the default output state

ISO7341FCDWR is the quad channel member of the ISO734x family, with three channels forward and one back, in a sixteen pin wide body SOIC, rated 3000 volts root mean square of withstand. The family is published with two default output states: the plain C code drives the output low when the input side loses power, and the FC code drives it high.

That default is a fail-safe decision rather than an electrical one. A gate drive signal that must stay off when the controller loses power wants the low default; a chip select or an enable that must stay deasserted wants the opposite polarity, and the code that holds the safe state is the one to order rather than the one in stock.

Twenty five megabits with twenty nanoseconds typical

The C grade of ISO7341FCDWR runs to 25 megabits per second with a propagation delay of 20 nanoseconds typical and 31 maximum, and a maximum of 58 nanoseconds over the full temperature and supply window. The FC code is specified at 22 nanoseconds typical with 35 maximum and 66 nanoseconds at the limit.

Those two rows describe the same silicon with two different output stages, and the fail-safe version is slightly slower because the default state has to be detected and enforced. At 25 megabits a bit is 40 nanoseconds, so the difference between 31 and 35 nanoseconds of maximum delay is inside the margin a synchronous link needs, not outside it.

One thousand four hundred and fourteen volts peak of repetitive isolation

The isolation rows of ISO7341FCDWR are 1414 volts peak of maximum repetitive isolation voltage, 4242 volts peak of maximum transient isolation voltage and 3000 volts root mean square of withstand for 60 seconds. The external clearance and creepage are greater than 8 millimetres and the package is the sixteen pin wide body SOIC.

The 1414 volt repetitive figure is what the barrier holds every switching cycle for the life of the product, and it is the number to compare against the working voltage of the circuit rather than the 3000 volt type test. A 400 volt direct current bus with a 1000 volt surge is inside the repetitive rating, and a 1000 volt bus is not.

Three forward, one back, and the enable pins

ISO7341FCDWR carries three channels from side one to side two and one channel back, with an enable pin on each side, in the sixteen pin wide body. The disabled output is high impedance, and the enable and disable delays are 7 to 13 nanoseconds, which is fast enough to park the link between transactions without a protocol level wait.

The reverse channel is normally the fault or ready line, and its direction is what distinguishes this code from the four forward version. A board that needs a fault return has to buy the three and one part, and a board that only needs four forward channels should not pay for a reverse channel it will tie off.

Seven and a half milliamps, and the immunity at three thousand volts

The supply current of ISO7341FCDWR is in the low milliamp range per side at 1 megabit, which is the figure the family quotes in its feature list, and the common mode transient immunity is 25 kilovolts per microsecond minimum with 70 typical on the higher of the two quoted supplies. The barrier is a silicon dioxide layer with about 1 picofarad of capacitance.

The 3000 volt rating with 8 millimetres of creepage is what separates this family from the 2500 volt parts in the same catalogue, and the extra 500 volts is bought with a wider body rather than a different barrier material. A product certified to a 300 volt mains category needs the wider body, and a 3000 volt part is the smallest one that satisfies it.

Where three thousand volts is the actual requirement

ISO7341FCDWR belongs on the interface between a mains connected power stage and a low voltage controller, on a smart meter, on a photovoltaic inverter, on an industrial drive certified to a 300 volt mains category, and on any board where the isolation working voltage sits above the 1000 volt class the 2500 volt parts cover.

The extra 500 volts of withstand and the 1414 volt repetitive rating are the two rows that decide those cases, and the wide body is the price of both. Where the working voltage is below 560 volts peak, the 2500 volt family in the same catalogue does the same job in an eight pin body and is the cheaper choice.

What three thousand volts changes on the board

The 3000 volt rating comes with a wide body and more than 8 millimetres of creepage, and that distance has to survive the assembly process as well as the drawing. A slot under the body, a keep out on both sides and no test point across the gap are the three rules that keep the rating, and a single via placed in the gap removes it without changing any part number.

The second consequence is the supply. A 3000 volt barrier is normally fed by an isolated converter with a matching rating, and the converter, not the isolator, is the part that decides the board area. Buying the isolator at the right rating and the converter at a lower one is the mistake this page exists to prevent.

Choosing between the C and the FC code is a question about the safe state of the load, not about speed. Our BOM scrubbing page covers the two codes against the bill of materials, and the vendor consolidation page covers holding both on one line.

When is a high default the safe state? On a chip select or an active low enable, where high means deasserted and the load stays off. On a gate drive it is the wrong polarity, and the C code is the one to order.

Does the FC code cost anything in speed? Two nanoseconds of typical delay and eight nanoseconds at the maximum limit, which is inside the margin at 25 megabits and outside it at 50 megabits.

Is the pinout the same as the C code? Yes. Only the default output state differs, so the two codes are interchangeable on a board that tolerates either safe state.