Contact Us

ISO6762FQDWRQ1

Brand: Texas Instruments
Texas Instruments ISO6762FQDWRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO6762FQDWRQ1 — Power Management & Signal Chain | Superb Automation

ISO6762FQDWRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO6762FQDWRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO6762FQDWRQ1: four channels forward and two back

The ISO6762FQDWRQ1 is the six channel member of the ISO676x family with a mixed direction map: four channels run forward and two run back. That split is what a controller needs when it sends four signals out to the field and reads two status lines back, for example four gate drives and two fault returns, or four chip selects and two ready flags. One body covers the whole crossing instead of a six channel part plus a second package for the return path.

The F in the string sets the default state. When input power or the input signal is lost, every output on this part goes low. On the plain version the same event leaves the outputs high. That choice decides how a safe state is reached at the receiving end without a processor having to intervene, and it has to be settled before the order code is written.

Electrically the part is the same family as the rest of the ISO676x group. The barrier is rated to 5000 VRMS for one minute under UL 1577, certified to DIN EN IEC 60747-17, with 1500 VRMS of working voltage and a 10 kV surge capability. Data rate reaches 50 Mbps, propagation delay is 11 ns typical and 18 ns maximum at 5 V, and the supply current is 1.6 mA per channel typical at 1 Mbps. Both sides accept 1.71 V to 5.5 V, so a 1.8 V processor can talk to a 5 V field interface through the one part.

Key data for the ISO6762FQDWRQ1

ChannelsSix, four forward and two reverse, with the reverse pair sharing the same barrier
Default stateOutput low on loss of input power or input signal, which is the F variant
Data rate50 Mbps maximum specified
Isolation5000 VRMS for 60 s per UL 1577, 1500 VRMS working voltage, 10 kV surge, VDE 0884-17 certified
Supply1.71 V to 1.89 V and 2.25 V to 5.5 V on both sides, 1.71 V to 5.5 V translation
TimingPropagation delay 11 ns typical at 5 V, 18 ns maximum, pulse width distortion 7 ns maximum
Immunity150 kV per microsecond CMTI typical, low emissions stated for the family

Body, packing and marking data

BodySOIC DW, 16 pins, 10.30 mm by 7.50 mm, wide body
Packing2000 pieces on a 330 mm reel on the published rows, carrier width 16.4 mm
FinishNIPDAU plating, moisture level 2, 260 C peak reflow, one year floor life
TemperatureMinus 40 C to plus 125 C

Order code note on the Q1 suffix

The industrial document for this family publishes ISO6762DWR and ISO6762FDWR, each at 2000 pieces on a large reel. It does not print a Q1 row for this body, even though the tape and reel table at the back carries a Q1 column. The string on this page therefore needs a confirmation step before it goes on a purchase order, and the confirmation has to come from the vendor or from a ship record, not from a distributor search field that accepts any text.

At goods inwards the practical rule is to compare the carton marking with the row that was ordered, not with the catalogue string. If the carton reads 6762F and the order read Q1, hold the lot and ask. If the vendor confirms that the Q1 release uses the same die and the same 2000 piece reel under a separate document, record that confirmation with the lot so the next receipt does not reopen the same question.

Where a four and two split fits

Motor control cabinets, remote IO blocks and instrument front ends all send more signals out than they read back. Four forward channels carry chip selects, gate drives or relay commands, and the two reverse channels carry fault flags or a ready line. With the default low on the F version, a lost field supply pulls every return line low, which is the state most fault handlers already treat as an alarm.

When a board is being moved off an optocoupler row, the first thing to compare is not the isolation rating but the pin map and the default state. Our pin to pin cross reference page sets out the comparison, and the date code management page covers what to record on the incoming lot for a barrier part with a qualification question attached to its string.

Questions we get on this code

Buyers ask whether the reverse channels cost anything in speed. They do not. All six channels are rated to the same 50 Mbps and the same 11 ns typical delay, and the direction only changes which side of the barrier the input buffer sits on. What does change is the pin assignment, so a footprint that was laid out for the all forward member of the family will not accept this one without a map check.

The second question is about the supply rails. Each side needs its own decoupling, 0.1 uF close to the pin and 1 uF nearby, because the barrier switches charge across and a shared rail couples the two grounds back together. A board that shares one regulator across the barrier has no barrier in practice, whatever the part is rated to.