Contact Us

ISO3086DWR

Brand: Texas Instruments
Texas Instruments ISO3086DWR is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ISO3086DWR — Power Management & Signal Chain | Superb Automation

ISO3086DWR

Texas Instruments — Power Management & Signal Chain

Product Overview

The ISO3086DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

ISO3086DWR: isolated full-duplex RS-485 transceiver at 20 Mbps in a 16-pin SOIC

ISO3086DWR is an isolated four-wire RS-485 transceiver with a separate driver pair and receiver pair in a SOIC body of 16 pins. The 3086 code is the full-duplex member of the ISO308x family, so the driver and the receiver sit on separate bus pairs and the line can carry traffic in both directions at once. It signals at up to 20 Mbps, presents one eighth of a unit load, and isolates the bus side from the logic side with a 4000 V peak basic insulation rating.

Order code and package

Order codeISO3086DWR
Functionisolated full-duplex RS-485 transceiver
PackageSOIC, 16 pins, DW body
Signaling rateup to 20 Mbps
Bus loadone eighth unit load, up to 256 nodes
StandardTIA/EIA RS-485
Isolation4000 V peak basic insulation per VDE 0884-17, 560 V peak working voltage
UL rating2500 V RMS per UL 1577
Bus capacitance16 picofarads typical
ESD12 kV HBM between bus pins and the bus side ground, 6 kV to the logic side ground
Protectionthermal shutdown
Supply5 V on both sides
Temperature rangeminus 40 to plus 85 C

Electrical parameters that decide the application

Duplexfull, four bus pins, driver and receiver independent
Transient immunity50 kV per microsecond typical
Node count256 at one eighth unit load
Driverdifferential output, enabled separately from the receiver
Receiverfailsafe output on an open or terminated bus
CertificationsVDE 0884-17, UL 1577, CSA 62368-1
Bus pinsprotected against the faults listed in the absolute maximum table
Logic side5 V, TTL compatible

Points to check before this part goes on a BOM

Full duplex is the reason this code exists. A half-duplex part has to turn the driver around between a request and a reply, and that turnaround costs a fixed number of bit times at every transaction. On a control loop polled at 1 kHz, four wires remove that cost entirely.

One eighth unit load allows 256 nodes on one bus, which is the number that matters when a machine has a drive, an encoder, a safety relay and a remote IO block on the same pair. A quarter load part halves that count and usually forces a repeater into the cabinet.

The 16 picofarad bus capacitance is low enough that a 20 Mbps line stays within the rise time budget on a realistic cable length. At 20 Mbps one bit is 50 nanoseconds, so cable capacitance and stub length dominate the signal quality long before the transceiver does.

Thermal shutdown protects the driver when a bus fault holds it in a high current state. It is a survival feature, not a fault output, so a board that needs to report the event has to detect it from the traffic rather than from a pin on this part.

Where this order code fits

Motion controllers, encoder links and long multidrop industrial buses order this code when the protocol needs simultaneous transmit and receive rather than a turnaround delay. Boards comparing it with a neighbouring part start from our Component Lead Time Solutions page, and boards replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Can this part be used on a two-wire bus? No. The 3086 is the four-wire full-duplex member; the half-duplex codes in the same family are the ones for a two-wire bus.

Does it need a separate isolated supply? Yes, the bus side needs its own 5 V isolated rail, since the barrier isolates data and not power.

SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.