ISO1176DWR
Product Specifications
ISO1176DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1176DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1176DWR: isolated RS-485 Profibus transceiver rated to 40 Mbps
ISO1176DWR is an isolated RS-485 transceiver for Profibus networks in a SOIC body of 16 pins. It combines a galvanically isolated differential driver and receiver that meet EN 50170 and TIA/EIA-485-A, carrying up to 40 Mbps across a 4000 V peak barrier and supporting 160 nodes on one bus. The DWR order code is the wide body 16-pin SOIC on a reel.
Order code and package
| Order code | ISO1176DWR |
| Package | 16-pin wide body SOIC, DW |
| Packing | tape and reel |
| Signalling rate | up to 40 Mbps |
| Isolation | 4000 V peak per VDE 0884-17, 560 V peak working |
| Nodes | up to 160 transceivers on one bus |
| Bus capacitance | 10 pF maximum |
| Failsafe | receiver output defined on bus open, short and idle |
Electrical parameters that decide the application
| Differential output | exceeds 2.1 V into a 54 ohm load |
| Transient immunity | 50 kV per microsecond typical |
| Bus ESD | 16 kV human body model to GND2, 6 kV to GND1 |
| Logic inputs | 3.3 V inputs, 5 V tolerant |
| Enable | active high driver enable with isolated ISODE output |
| Chip enable | PV pin forces all outputs high impedance |
Family variants and how they differ
| ISO1176 | 40 Mbps, Profibus, 160 nodes, this order code |
| ISO3082 | 20 Mbps half duplex RS-485, 256 nodes |
| ISO3080 | 20 Mbps full duplex RS-485 |
| ISO1176DW | tube packing of the same part |
Points to check before this part goes on a BOM
The Profibus qualification is the reason this part exists: EN 50170 fixes the driver output, the termination and the 1.5 Mbps to 12 Mbps rates that a process network runs at. The 40 Mbps ceiling is four times the fastest standard rate and is there for proprietary links on the same silicon, not because a Profibus segment will ever use it.
The 4000 V peak rating is a VDE 0884-17 figure with a 560 V peak working voltage, and it is not the same statement as a 2500 V RMS UL withstand. A customer comparing the ISO1176 against a 2500 V RMS part is comparing a peak repetitive rating with a one minute test, and the two numbers are not convertible by a factor of 1.4.
Bus loading is 10 pF maximum and 160 nodes, which is roughly twice the 32 node unit load limit of a classic 75176 style transceiver. That headroom is what allows a long process segment to keep its drivers without a repeater, and it disappears if the bus protection components add more capacitance than the transceiver does.
The ISODE pin outputs the enable state across the barrier, so the controller can read back whether the driver is actually on rather than assuming the enable command arrived. On a half duplex segment where a stuck driver takes the whole bus down, that feedback is the difference between a diagnosable fault and a silent one.
The PV pin forces every output to high impedance, which allows a module to be isolated from the bus without removing power. This is the pin to use for a hot swap arrangement, and it is not interchangeable with the driver enable because it also disables the receiver.
Transient immunity of 50 kV per microsecond typical is quoted for the barrier, not for the bus pins. A drive cabinet with a switching inverter couples the common mode transient into the cable, and the barrier rating is what keeps that current out of the controller ground while the bus pins themselves still see the full transient.
The bus pins are protected to 16 kV human body model against GND2 and 6 kV against GND1, and the asymmetry is deliberate: the cable side carries the surge, the logic side does not. A protection network added on the logic side does nothing for the rating that matters.
Segment termination for Profibus is a pair of 390 ohm bias resistors and a 220 ohm terminator at each end, and the bias network draws current continuously. On an isolated segment that current comes from the isolated supply, so a segment with 32 nodes and two terminators has a standing load that the transformer driver has to cover at all times, not only while transmitting.
The 40 Mbps rate is not usable across a long Profibus cable. At that rate the bit time is 25 ns and the cable delay alone exceeds it after a few tens of metres, so the rate belongs to short backplane links while the process segment runs at 1.5 Mbps to 12 Mbps.
Termination resistors on an isolated Profibus segment have to be powered from the isolated side, and the bias network draws current even when the bus is idle. A 390 ohm pair across 5 V draws about 12 mA, which is several times the transceiver's own supply current, so the isolated rail is sized by the termination and not by the part. Removing the terminators to save current leaves the segment without a defined idle level.
Where this order code fits
It is used on Profibus DP segments, isolated RS-485 process networks, drive and motor control links, building automation buses and any multipoint link that crosses a ground barrier. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Is it half duplex or full duplex? Half duplex, with a driver enable and a receiver enable. The isolated ISODE output reports the driver state to the controller side.
Can 3.3 V logic drive it directly? Yes. The logic inputs are 3.3 V devices that tolerate 5 V, so a 3.3 V controller connects without a translator.
Does it include termination? No. The 120 ohm terminators and the failsafe bias resistors are external, and their capacitance counts against the 10 pF bus figure.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.