ISO1042BQDWVRQ1
Product Specifications
ISO1042BQDWVRQ1
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1042BQDWVRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1042BQDWVRQ1: isolated CAN FD transceiver with 70 V bus fault protection in an 8-pin wide SOIC
ISO1042BQDWVRQ1 is a galvanically isolated CAN and CAN FD transceiver with a 70 V fault tolerant bus side in a SOIC body of 8 pins. The DWV body is the 8-pin wide SOIC at 5.85 mm, and the Q1 suffix makes this the automotive qualified order code of the ISO1042 family. It carries classic CAN at 1 Mbps and CAN FD at 5 Mbps across a silicon dioxide barrier rated 5000 V RMS for one minute, with 7071 V peak transient and 1500 V peak working voltage under VDE 0884-17.
Order code and package
| Order code | ISO1042BQDWVRQ1 |
| Function | isolated CAN and CAN FD transceiver |
| Package | SOIC, 8 pins, 5.85 mm wide body, DWV |
| Data rate | classic CAN to 1 Mbps, CAN FD to 5 Mbps |
| Standard | ISO 11898-2:2016 physical layer |
| Bus fault protection | plus and minus 70 V DC |
| Common mode range | plus and minus 30 V |
| Isolation | 5000 V RMS for one minute per UL 1577 |
| VDE rating | 7071 V peak transient, 1500 V peak working, reinforced and basic options |
| Loop delay | 152 nanoseconds |
| Side 2 supply | 4.5 V to 5.5 V |
| Temperature range | minus 40 to plus 125 C ambient |
| Qualification | automotive Q1 order code |
Electrical parameters that decide the application
| Bus ESD | plus and minus 16 kV HBM on the bus pins |
| Protection features | TXD dominant time out, undervoltage lockout on both supplies |
| Isolation barrier | silicon dioxide, not a magnetic coupler |
| Certifications | UL 1577, VDE 0884-17, GB 4943.1, IEC 62368-1, IEC 60601-1, IEC 61010-1 |
| Approvals | CQC, TUV and CSA |
| Emissions | low emissions, system level ESD, EFT and surge immunity claimed |
| Package options in family | 16-pin SOIC and this 8-pin wide SOIC |
| Controller interface | direct to a 3.3 V or 5 V CAN controller on side 1 |
Points to check before this part goes on a BOM
The 70 V bus fault number is the reason this part appears on battery systems. A short from the CAN pair to a 48 V rail is a real harness fault, and a transceiver rated 40 V or 58 V fails at that point rather than riding through it until the fuse opens.
A 152 nanosecond loop delay is comfortable at 1 Mbps, where one bit is 1000 nanoseconds. In the FD data phase at 5 Mbps one bit is 200 nanoseconds, so the delay eats most of a bit and the bus length and the sample point have to be worked out from the delay rather than assumed from the classic CAN figure.
The isolation barrier is silicon dioxide with a 30 year life projection at the working voltage. A board that needs basic rather than reinforced insulation can use the basic option of the same die, and the difference is in the certification, not in the pin out.
The 8-pin body has no separate logic supply pin, so side 1 runs from the controller rail and side 2 from 4.5 V to 5.5 V. A 3.3 V only board still needs a 5 V isolated supply for the bus side, which is the part of the BOM buyers most often forget when they compare this code with a non-isolated transceiver.
Where this order code fits
48 V battery management, traction inverter control and charger boards order this code when the CAN bus runs between two ground domains that cannot be tied together. Boards comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and boards replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Is 70 V fault protection the same as 70 V common mode? No. The fault rating is a survival rating for a short to a high voltage; the guaranteed common mode range for correct data is plus and minus 30 V.
Does the Q1 code change the data rate? No. The 5 Mbps FD capability and the 152 nanosecond loop delay belong to the family document; the Q1 suffix adds the automotive qualification.
SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.