Product Specifications

INA220AIDGSR — Power Management & Signal Chain | Superb Automation

INA220AIDGSR

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA220AIDGSR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA220AIDGSR: 12 bit current and power monitor with a two wire interface

INA220AIDGSR is a bidirectional current, voltage and power monitor in a VSSOP body of 10 pins. It measures shunt drop and bus voltage on a rail up to 26 V and reports current, voltage and power over an I2C or SMBus interface, with a separate shunt input that allows low side sensing. The DGSR order code is the 10-pin VSSOP on a reel.

Order code and package

Order codeINA220AIDGSR
Package10-pin VSSOP, 3.0 mm by 3.0 mm
Packingtape and reel
Bus range0 V to 26 V, high side or low side
InterfaceI2C and SMBus, 16 programmable addresses
Resolution12 bit ADC
Supply3 V to 5.5 V, 1 mA maximum
GradeA grade here, with the B grade carrying the tighter accuracy

Electrical parameters that decide the application

Shunt full scale40 mV at gain 1, 80 mV at gain 2, 160 mV at gain 4, 320 mV at gain 8
Offset voltage10 microvolt typical, 100 microvolt maximum at gain 2 on the A grade
Gain error0.2 percent typical on the current sense path
ADC resolution12 bit on both shunt and bus
Conversion time276 to 304 microseconds in the fastest setting
Address pinsA0 and A1 allow 16 addresses on one bus
Bus voltage full scale26 V, do not exceed on VBUS

Family variants and how they differ

INA220A12 bit, 26 V, standard accuracy, this order code
INA220B12 bit, 26 V, tighter offset and gain limits
INA21912 bit, 26 V, earlier register map
INA22616 bit, 36 V, alert output

Points to check before this part goes on a BOM

The programmable gain sets the shunt full scale, and that choice decides the resolution of every current reading. At gain 1 the 40 mV full scale on a 12 bit converter is 19.5 microvolt per count, and with a 10 milliohm shunt that count is 1.95 mA, so a 5 A rail only uses a quarter of the range and 75 percent of the resolution is thrown away.

Offset of 10 microvolt typical against a 40 mV full scale is 0.025 percent of range, but against a 5 mV reading it is 0.2 percent. The A grade is specified at 100 microvolt maximum in the programmable gain settings, and that limit sits directly on the smallest currents a battery monitor is asked to resolve.

Current is computed from a calibration register the host writes, so the accuracy of the reported amperes depends on the shunt value the host declares. A 1 percent shunt puts 1 percent on every current and power reading regardless of the converter, and the internal multiplier does not correct for it.

Power is the product of the current register and the bus voltage register, so it inherits both errors and it is not a separate measurement. On a load that swings quickly the current and voltage registers are captured at different moments, and the product is only meaningful on a steady rail.

The 26 V limit applies to the bus voltage input and not to the supply. A 24 V rail with a transient that rings above 26 V puts the input over its rating, so a rail that switches inductive loads needs a clamp or a divider on VBUS before it reaches the pin.

Sixteen addresses come from two pins tied to ground, supply, SDA or SCL, which allows a bank of modules on one bus. The two pins are sampled continuously rather than latched, so a long stub on an address line that floats at power up can place the device at an address the software is not looking for.

The calibration register is written by the host and everything downstream depends on it. Its value is a fixed point number derived from the shunt resistance and the current least significant bit, and a host that writes the same constant for two different shunt values reports two different currents for the same load with no error indication.

The bus voltage input measures at the device pin, not at the load. On a rail with a long trace from the shunt to the connector the reading misses the drop in that trace, which is exactly the part of the budget a power measurement is usually asked to find, so the sense point belongs on the drawing.

Reading a shunt that sits on a rail which is switched on and off is a different problem from reading a steady rail. The 12 bit converter integrates over its conversion window, so a rail that switches at 100 kHz aliases into the current register unless the averaging is set longer than the switching period. A reading that jumps by a fixed step every few updates is the signature of that aliasing rather than of a noisy load.

Where this order code fits

It is used in servers, telecom rectifiers, notebooks, battery chargers, automotive modules and test equipment that need a digital current and power reading rather than an analog loop. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the MCU Cross Reference page.

Questions buyers ask

What is the difference between the A and B grades? The B grade carries tighter offset and gain limits and therefore a tighter total error over temperature. The A grade in this order code is the standard part and its limits are the looser column in the data sheet.

Can it measure a negative current? Yes. The shunt input is bidirectional, so a battery that charges and discharges through the same shunt reports both directions as signed values.

Does it need an external reference? No, the reference is internal, and the bus voltage and shunt readings are both referred to it, which is why the accuracy figures are quoted as a percentage of reading.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Lead Time Solutions page sets out the checks that keep a substitute from failing on the bench.