INA170EA-2K5
Product Specifications
INA170EA-2K5
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA170EA-2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA170EA-2K5: a high side current shunt monitor with a current output
INA170EA-2K5 is a high side bidirectional current shunt monitor with a current output at 1 milliamp per volt of shunt drop, in the eight pin MSOP on a 2500 piece reel. Common mode runs from 2.7 to 60 volts independently of a supply that runs from 2.7 to 40 volts, quiescent current is 75 microamps, and the part draws its bidirectional offset from one resistor and a reference.
The current output is what makes this part different from the digital monitors that have taken over most current sensing. It lets the load resistor set the gain at the receiving end, it lets several channels be summed into one analogue input, and it makes the measurement immune to the resistance of the cable between the shunt and the controller. The cost is that the load resistor's tolerance and drift are part of the channel, and the offset has to come from somewhere clean.
INA170EA-2K5 as the vendor document publishes it
| Output | current, one milliamp per volt of shunt drop |
| Full scale sense voltage | 100 to 500 millivolts, set by the shunt and the load |
| Linear window | 10 to 150 millivolts of sense voltage |
| Input common mode range | plus 2.7 to plus 60 volts, independent of the supply |
| Supply range | plus 2.7 to plus 40 volts |
| Common mode rejection | 100 dB minimum, 120 typical at a 50 millivolt sense |
| Offset | 200 microvolts typical, 1 millivolt maximum referred to the input |
| Offset drift | 1 microvolt per degree |
| Supply rejection | 0.1 microvolts per volt typical, 10 maximum |
| Input bias current | 10 microamps |
| Offset programming | offset equals load resistance over programming resistance, times the reference |
| Programming current through ROS | up to 1 milliamp |
| Output transconductance | 0.990 to 1.010 milliamp per volt |
| Total output error | 0.5 per cent typical, 2 maximum at a 100 millivolt sense |
| Nonlinearity | 0.01 per cent typical, 0.1 maximum |
| Output swing to supply | within 0.9 volts typical, 1.2 maximum |
| Bandwidth | 400 kHz into a 10 kohm load |
| Settling to 0.1 per cent | 3 microseconds on a 5 V step |
| Output current noise | 20 picoamps per root hertz |
| Quiescent current | 75 microamps typical, 125 maximum |
| Body | eight pin MSOP, marking INA170EA |
| Temperature range | minus 40 to plus 85 degrees |
| Catalogue code | INA170EA-2K5 |
| Vendor string | INA170EA/2K5 |
| Carrier | 2500 piece reel, MSOP-8 |
| Grade | EA, extended industrial temperature |
A current output: one milliamp per volt of shunt drop
INA170EA-2K5 does not produce a voltage. It converts the differential voltage across a shunt into a current at 1 milliamp per volt, with a transconductance window of 0.990 to 1.010 milliamp per volt over a sense voltage from 10 to 150 millivolts, and the load resistor at the output decides what that current becomes. A 25 kohm load turns 100 millivolts of shunt drop into 2.5 volts; a 10 kohm load turns the same into 1 volt and gives 400 kHz of bandwidth instead of 200.
The current output is the point of the part rather than a quirk. It lets the gain be set at the receiving end, it makes the signal immune to series resistance in the cable between the shunt and the measurement, and it allows several channels to be summed into one load. The cost is that the load resistor's tolerance enters the gain directly, so a 1 per cent resistor is a 1 per cent gain error on top of the 0.5 per cent typical total output error, and the resistor's temperature coefficient is now part of the channel's drift.
Common mode from 2.7 to 60 volts, independent of the supply
The input common mode range of INA170EA-2K5 is 2.7 to 60 volts and the supply range is 2.7 to 40 volts, and the vendor is careful to say that the two are independent. The part can measure a 48 volt rail while running from 3.3 volts, which is the configuration a telecom or automotive board actually wants, and it can measure a 2.7 volt rail from the same 3.3 volt supply. Common mode rejection over that window is 100 dB minimum and 120 typical with a 50 millivolt sense voltage.
The independence has one boundary worth stating. The offsetting amplifier's input, which sets the bidirectional offset, has to stay between 1 volt and the supply minus 1 volt, so the reference that feeds it is limited by the amplifier's own supply rather than by the common mode. On a 3.3 volt supply that means a reference between 1 and 2.3 volts, which is exactly mid rail, and it means a 5 volt reference cannot be used to offset a 48 volt measurement without a divider that then carries its own error.
Bidirectional offset from one resistor and a reference
INA170EA-2K5 measures current in both directions by offsetting the output, and the offset is set by a resistor from the ROS pin to the reference: the vendor gives the relation as the offset voltage equal to the load resistance divided by the programming resistance, multiplied by the reference voltage. A 25 kohm load and a 100 kohm programming resistor with a 2.5 volt reference produce 625 millivolts of offset, which is the mid point of a 1.25 volt output span and therefore the zero current point.
Two details decide whether that offset is stable. The programming current through the resistor is limited to 1 milliamp, so the resistor has to be large enough to keep the reference inside its own output current, and the offsetting amplifier's drift, 10 microvolts per degree, is referred to its input and therefore divided by nothing: it appears at the output magnified by the load resistor and the transconductance. A precision reference and a low drift resistor pair are part of the measurement, not part of the support circuit.
A full scale of 100 to 500 millivolts is a choice, not a limit
The full scale sense voltage of INA170EA-2K5 is quoted as 100 to 500 millivolts, and the window is set by the linearity of the transconductance rather than by a fixed gain. Nonlinearity is 0.01 per cent typical and 0.1 maximum over a sense voltage of 10 to 150 millivolts, so a circuit that wants the best linearity keeps the shunt drop inside that band and uses the load resistor for the rest of the gain. A 1 milliohm shunt carrying 100 amps develops 100 millivolts, which is the top of the good window and the reason the part suits battery and motor currents.
Going above 150 millivolts is possible and costs linearity; going below 10 millivolts is where the offset, 200 microvolts typical and 1 millivolt maximum referred to the input, becomes a large share of the signal. On a 10 millivolt shunt drop the maximum offset is 10 per cent of full scale, which is a shunt that has to be chosen larger or an amplifier that has to be trimmed. The vendor's own error budget puts the total output error at 0.5 per cent typical and 2 per cent maximum with a 100 millivolt sense, and that is the number to carry into a specification.
Seventy five microamps and 400 kilohertz
INA170EA-2K5 draws 75 microamps typical and 125 maximum quiescent, which is what a current monitor in a battery or a portable instrument needs, and it delivers 400 kHz of bandwidth into a 10 kohm load with 3 microseconds of settling to 0.1 per cent on a 5 volt step. Output current noise is 20 picoamps per root hertz and 7 nanoamps RMS over a 100 kHz bandwidth, which into a 25 kohm load is 175 microvolts RMS, a figure that matters when the shunt drop is small.
The output stage swings to within 0.9 volts of the supply typical and 1.2 maximum, and to within 0.6 and 1.0 volts of the common mode at the other end, so on a 3.3 volt supply the usable output is roughly 1 to 2.4 volts. That is a narrow window and it is the reason the offset resistor is chosen to put zero current in the middle of it rather than at the bottom. The output impedance is 1 gigohm in parallel with 5 picofarads, so the load resistor is the only thing setting the gain and the next stage has to be a high impedance one.
Where a current output shunt monitor wins
A current output monitor is the right choice when the measurement has to travel: a shunt on a bus bar with a metre of cable to the controller, several channels summed into one analogue input, or a channel whose gain has to be changed at the receiving end without touching the sensor board. It is also the right choice when the shunt sits at a common mode the supply cannot follow, which is the whole point of the independent 60 volt window.
It is the wrong choice when the load resistor cannot be held stable, when the board has no clean reference for the offset, or when the channel needs better than 2 per cent total error without a trim. Those cases belong to the digital output monitors with an internal conversion and a gain error specified over temperature. This part is analogue, and every error in its chain, including the resistor the customer chooses, is visible in the result.
A reel suits a board that carries several of these, which is common on a multi rail supply. Our BOM scrubbing page covers the code match, and the pin to pin page covers the digital output alternatives when the analogue chain is the problem rather than the part.
What sets the output voltage? The load resistor: 1 milliamp per volt of shunt drop means 100 millivolts of sense into 25 kohm is 2.5 volts.
Can it measure a 48 volt rail from a 3.3 volt supply? Yes. The common mode window is independent of the supply, and the only constraint is that the offsetting amplifier's reference stays between 1 volt and the supply minus 1 volt.