INA134UA-2K5
Product Specifications
INA134UA-2K5
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA134UA-2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA134UA-2K5: the same line receiver on a 2500 piece reel, with the tape width that goes with it
The INA134UA-2K5 is the hyphen spelling of the reel row, which the addendum prints as INA134UA/2K5 at 2500 pieces. The tape is 12.4 mm wide on a 330 mm reel, the moisture level is 3 with 168 hours of floor life, and the part is marked INA134UA. It is the carrier a production line uses for an eight pin SOIC, and it is the only active carrier for this part.
The device is a 0 dB differential line receiver: 3.1 MHz of small signal bandwidth, 14 V per microsecond of slew, 0.0005 per cent of distortion at 1 kHz, minus 100 dBu of noise floor, plus 23 dBu of headroom and 90 dB of common mode rejection. Each channel draws 2.9 mA maximum on a supply from plus or minus 4 V to plus or minus 18 V.
The INA134UA-2K5 rows as the addendum publishes them
| Part class | Unity gain audio differential line receiver, trimmed 25 kΩ network |
| Vendor status | Active, production |
| Data sheet | SBOS071, Burr-Brown PDS-1390A, July 1997 |
| Addendum row it normalises to | INA134UA/2K5, 2500 pieces |
| Gain | 1 V/V, 0 dB, fixed |
| Gain error | 0.1 per cent maximum |
| Total harmonic distortion plus noise | 0.0005 per cent at 1 kHz |
| Noise floor | Minus 100 dBu |
| Headroom | Plus 23 dBu |
| Input offset voltage | 1 mV maximum |
| Common mode rejection | 90 dB typical |
| Input impedance | 50 kΩ differential |
| Bandwidth | 3.1 MHz small signal |
| Slew rate | 14 V per microsecond |
| Output | Plus or minus 16 V, 500 pF stable |
| Supply range | Plus or minus 4 V to plus or minus 18 V |
| Quiescent current | 2.9 mA maximum per amplifier |
| Body | SOIC, D outline, 8 pins |
| Carrier | 2500 pieces, 330 mm reel, 12.4 mm tape |
| Moisture level | Level 3, 168 hour floor life |
| Dual sibling | INA2134UA/2K5, 14 pin SOIC, 2500 pieces |
0 dB of gain on a trimmed network
INA134UA-2K5 is a unity gain differential amplifier built for audio line receivers, and the whole function is four trimmed resistors around one op amp. The gain is 1 V/V fixed, the gain error is 0.1 per cent maximum and the nonlinearity is 0.0001 per cent of full scale with a 1 ppm per degree drift, so the network does not contribute a measurable distortion term. The input network is 50 kohm differential and 50 kohm common mode.
Building the same function from four 0.1 per cent resistors and an audio op amp is possible and usually cheaper in unit cost, and it is worse in every other way: four parts to place, four tolerances to stack, and a ratio match that depends on how the board heats. The integrated network is trimmed as a set, so the common mode rejection is a specification rather than a hope. That is what the part is bought for.
16 V of swing on 18 V rails and a 500 pF load limit
The output of INA134UA-2K5 swings to within 1.8 V of the positive rail and 1.6 V of the negative rail, so on plus or minus 18 V the usable span is plus or minus 16 V, which is plus 26 dBu and above the plus 23 dBu headroom figure. Continuous output current is 60 mA, enough to drive a 600 ohm load to that level, and the load capacitance limit is 500 pF, which is lower than the difference amplifier family and is the row that decides whether a cable can be driven directly.
A 500 pF limit means a shielded cable of a few metres needs a series resistor or a buffer, because a cable is 50 to 100 pF per metre plus the connector. The usual arrangement is 47 to 100 ohms in series at the output, which isolates the capacitance and costs nothing in the audio band. Without it the part is stable on the bench and rings on the installed cable, which is the failure that gets blamed on the board.
0.0005 per cent at 1 kHz and a noise floor of minus 100 dBu
The audio rows are the reason to read this sheet: total harmonic distortion plus noise is 0.0005 per cent at 1 kHz with a 10 V rms input, the noise floor is minus 100 dBu over a 20 kHz bandwidth, and the headroom is plus 23 dBu with distortion below 1 per cent. Those three numbers describe a line receiver that will not be the limiting stage in a console or a broadcast chain.
The noise figure is quoted per the amplifier plus the thermal noise of the resistor network, which is why it moves when the source impedance moves. At minus 100 dBu the residual is about 7.7 microvolts rms, and the output noise over the audio band is 7 microvolts rms, so the network is not the dominant term at ordinary source impedances. Beyond a few tens of kohm of source impedance the current noise and the network thermal noise take over.
2.9 mA per amplifier and the 150 degree per watt SO-8
Each channel of INA134UA-2K5 draws 2.4 mA typical and 2.9 mA maximum, and the supply window runs from plus or minus 4 V to plus or minus 18 V. On a plus or minus 18 V supply that is about 100 milliwatts per channel dissipated in the package, and the junction to ambient figure is 150 degrees per watt in the SO-8 against 100 in the eight pin DIP, so the SO-8 runs 15 degrees hotter for the same current. In a rack at 50 degrees ambient that is still inside the 85 degree specification, but it is not inside it by much if two channels share a package.
The absolute maximum supply is 40 V total, the inputs survive 80 V, and the output is short circuit protected continuously to ground for one channel per package. On a dual, a short on one channel does not take the other with it because the two channels are independent, which the vendor states as a feature and which matters on a connector that can be miswired.
1 mV of offset, 90 dB of rejection and the ground loop it removes
Input offset on INA134UA-2K5 is 1 mV maximum with a 2 microvolt per degree drift, which is large for a precision part and irrelevant for an audio line receiver, where the signal is volts. What matters is the 90 dB of common mode rejection at a plus or minus 31 V common mode, because that is the number that removes the ground loop between two chassis plugged into different outlets. At 90 dB a 1 V ground difference becomes 32 microvolts at the output.
The rejection holds only if the source impedances match. A balanced line with 50 ohm build out resistors on both legs and a 1 kohm imbalance from a faulty connector drops the rejection by an order of magnitude, which is audible as hum. That is why the input network is 50 kohm and why the two legs should be terminated the same way: the amplifier is not the problem, the cable and the connectors are.
The UA reel, the PA tube and the dual INA2134
The current addendum lists one active row for the single: INA134UA-2K5 at 2500 pieces on a large reel, moisture level 3, 168 hour floor life, minus 40 to plus 85 degrees. The eight pin DIP version INA134PA is published in the package table but has no active reel row, so a through hole build is a broker purchase rather than a catalogue line. The dual INA2134UA is the fourteen pin SOIC at 2500 pieces on a reel.
The 330 mm reel with a 12.4 mm tape width is the standard carrier for the eight pin body, and the parts are marked INA134UA. Because the tube row is not active, a prototype build of a few hundred boards either takes a reel or takes cut tape, and cut tape on a moisture level 3 part has to be baked before reflow if the exposure time is not recorded. That is the practical difference between this part and a part with an active tube row.
Buying INA134UA-2K5
One reel covers a year of a modest audio product, and the level 3 moisture level means the reel should live in a dry cabinet once opened. The dual row is priced per channel lower and carries two channels on one 16.4 mm tape, so a stereo build should compare the two configurations before committing to two single reels.
Where the reel is not justified, the tube row at 75 pieces is active and is the same part, which is unusual in this catalogue and convenient. Our safety stock page covers how much to hold, and the date code page covers the floor life record for an opened reel.
Questions that arrive with this part number
Whether the hyphen is a different part is the first question, and it is not. Whether the reel and the tube are the same silicon is the second, and they are, with the carrier and the quantity as the only differences, which makes this family easier to schedule than the ones where the tube row was withdrawn.
The third is the load capacitance, 500 pF, which is the row that decides whether a cable can hang directly on the output. A 3 m cable at 100 pF per metre is already over the limit with the connector, so a series resistor is not optional and should be on the drawing rather than added at test. The fourth is the input network, 50 kΩ, which is a load on a 600 ohm line but not a significant one.