The INA125UA2K5 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA125UA/2K5: the A bin bridge amplifier on a 2500 piece reel

This string is the volume form of the integrated bridge front end: the tighter offset bin, the SO-16 body, the pin selectable reference and 2500 pieces on a large reel. It is the part a production bridge instrument should be ordering once the circuit is fixed, and it answers three questions in one string: which grade, which body and which carrier.

The function is unchanged across the family: gain from 4 to 10,000 with one resistor, a reference at 1.24, 2.5, 5 or 10 V by pin strap, 460 µA of supply current, a sleep pin, 250 µV offset, 2 µV per degree drift and 100 dB of common mode rejection.

The INA125UA/2K5 rows as the addendum publishes them

Part classInstrumentation amplifier with precision voltage reference
Vendor statusACTIVE, production data
Data sheetSBOS060
GradeA suffix, tighter trimmed offset bin
Catalogue stringINA125UA/2K5, stored here also as INA125UA2K5
Reference voltages1.24 V, 2.5 V, 5 V, 10 V by pin strap
Gain equationG = 4 + 60 kΩ divided by RG
Gain range4 to 10,000 V/V
Input offset voltage250 µV maximum, family row
Offset drift2 µV per degree maximum
Quiescent current460 µA
Supply rangeSingle supply 2.7 V to 36 V
BodySOIC, D outline, 16 pins
Carrier2500 pieces on a large reel
Tube siblingINA125UA, 40 pieces per tube
Plain bin reelINA125U/2K5, same reel different test limit
Moisture levelLevel 3, 260 degrees, 168 hour floor life
Temperature rangeMinus 40 to plus 85 degrees

Two thousand five hundred parts at one per channel is 2500 channels, which for a four channel transmitter is 625 boards. At a build rate of 50 boards a month that is a year of production on one reel, and a year at level 3 is a reel opened twelve times. The arithmetic is worth doing before the order, because a reel bought for a smaller rate is a stock that will outlive its floor life budget and its solderability.

Ratiometric bridge measurement at volume

A ratiometric channel is the reason to use this part rather than a plain amplifier and a reference, and at volume the saving is in test time rather than in components. A channel that cancels its reference drift does not need a two point calibration over temperature, and a calibration over temperature is the most expensive test in a transmitter's flow. Removing it is worth more than the price difference between an integrated and a discrete front end.

The cancellation requires that the converter's reference input takes the same node as the bridge excitation, and that the bridge is excited from the reference rather than from the supply. Both are board decisions, and both are invisible in a drawing that only names the parts.

Sixteen pins in a reel format

The reel format for a 16 pin SOIC is standard, and the feeder pocket is deeper than for an SO-8, so the tooling is different. A line that runs both part types needs two sets of tooling, which is a one time setup cost rather than a per build cost. The orientation check on the first article is the same discipline as for any reel.

The wide body also has a larger thermal pad area on the board, which at 460 µA is irrelevant electrically but helps the solder joint. A sixteen pin wide body with a good fillet on every pin is a part that survives vibration better than a small body, which matters in a transmitter mounted on a machine.

Reference headroom and the supply choice

The reference options and the supply have to be chosen together. A 24 V industrial supply with the 10 V tap gives a bridge 10 V and the amplifier plenty of headroom, and it dissipates more in the bridge than a 2.5 V excitation would. A 5 V supply with the 2.5 V tap is the low power choice, and a 3.3 V supply limits the circuit to the 1.24 V and 2.5 V taps with little headroom above the latter.

The excitation choice also sets the bridge sensitivity, because a bridge's output is proportional to its excitation. A 2 mV per volt bridge at 2.5 V produces 5 mV at full scale against 10 mV at 5 V, and the smaller signal makes the amplifier offset a larger fraction of the range. The trade is between power in the bridge and resolution at the amplifier, and it is worth a spreadsheet rather than a preference.

Buying INA125UA/2K5

The reel is active, the grade is the A bin, and the carrier is the one a production line wants. A purchase order that names all three is unambiguous; one that names only the family is not. The reference taps are not orderable options, so the build drawing has to carry the strap configuration.

For a volume transmitter our PCBA test coverage strategy page covers how a ratiometric channel can be tested without a temperature calibration, and the date code management page covers the rotation of a reel that lasts a year.

Second source and lifetime planning for a transmitter

A transmitter that is sold for fifteen years needs a front end that is available for fifteen years, and no single vendor part number guarantees that. The plan has three tiers: the primary part with a buffer, a documented substitute that has been checked on the actual channel, and a board revision that can take a different front end if neither is available. The third tier is the one nobody wants to fund, and it is the one that decides whether a programme survives an end of life notice.

The substitute check is a bench exercise rather than a data sheet comparison. A different integrated front end will have a different reference arrangement, a different gain equation and a different pin count, so the check is whether the existing board can be reworked or whether a revision is needed. Doing that check while the primary part is available is cheap; doing it after an end of life notice is a crisis.

The buffer quantity follows from the timeline. A substitute that needs a board revision takes six months to qualify and three months to build, so the buffer has to cover nine months of production plus shipping. For a monthly build of 50 boards at one part per board, that is 600 parts, which is a quarter of a reel and a very cheap insurance policy against a line stop.

The date code discipline closes the loop. A buffer of 600 parts bought in one lot and consumed over nine months will have a date code that ages with the stock, and a two year old part at the end of the buffer is the one that fails solderability. Rotating the buffer by buying the same quantity again and consuming the oldest first keeps the age bounded.

The board revision in the third tier does not have to be built. A drawing that has been checked against a substitute, with the pin differences noted and the gain equation rewritten, is a document that turns a crisis into a build when the time comes. Keeping that document current is a cheaper form of insurance than a buffer sized for a substitute nobody has checked.

Questions that arrive with this part number

Whether the A bin can be replaced by the plain bin if stock is short is the first question, and it can with a wider offset, which is a customer concession rather than a purchasing decision. Whether the reel covers a year of production is the second, and that depends entirely on the build rate. The third is the tap configuration, which is hardware and cannot be changed after the board is made.

The fourth is the moisture budget. A reel opened monthly at level 3 is comfortable, and a reel left open over a shutdown is not, so the storage arrangement should be in place before the first reel arrives rather than after.