INA117KU
Product Specifications
INA117KU
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA117KU from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA117KU: a difference amplifier that takes 200 V of common mode
The INA117KU is a unity gain difference amplifier built around a precision operational amplifier and a thin film resistor network on the same die, and its purpose is to measure a small differential voltage sitting on a very large common mode. With plus or minus 15 V supplies the common mode input range is plus or minus 200 V, the inputs are protected against 500 V of common mode and differential overload, the gain error is 0.05 per cent maximum, and the nonlinearity is 0.001 per cent maximum. Common mode rejection is 70 dB minimum, and the bandwidth is 200 kHz or 500 kHz depending on which fabrication flow the die came from.
The status on this string is not recommended for new builds, and the tube row and the reel row disagree in a way that matters: the tube string is NRND while the slash two K five reel string is listed as active. A buyer who needs this part in production should quote the reel string rather than the tube, and should confirm the status with the vendor at the time of order.
The INA117KU rows as the addendum publishes them
| Part class | Unity gain difference amplifier, high common mode |
| Vendor status | NRND on the tube string, active on the reel string |
| Data sheet | SBOS154C, revised January 2026 |
| Common mode input range | Plus or minus 200 V with plus or minus 15 V supplies |
| Input protection | 500 V common mode and 500 V differential overload |
| Gain | Unity, fixed by the internal network |
| Gain error | 0.05 per cent maximum |
| Nonlinearity | 0.001 per cent maximum |
| Common mode rejection | 70 dB minimum |
| Bandwidth | 200 kHz on one fabrication flow, 500 kHz on the other |
| Offset voltage, one flow | 120 µV typical, 1000 µV maximum |
| Offset voltage, other flow | 350 µV typical, 1000 µV maximum |
| Offset drift, one flow | 8.5 µV per degree |
| Offset drift, other flow | 3 µV per degree |
| Long term drift | 200 µV per month |
| Supply, single | 10 V minimum, 30 V typical, 36 V maximum |
| Supply, dual | Plus or minus 5 V to plus or minus 18 V |
| Body | SOIC, D outline, 8 pins |
| Thermal resistance, SOIC | 150 degrees per watt junction to ambient |
| Carrier, tube row | 75 pieces in a tube, level 3 at 260 degrees |
| Carrier, reel row | 2500 pieces on a large tape and reel, level 3 |
| Temperature range | Minus 40 to plus 85 degrees |
| Part marking | 117KU |
| Sibling bodies | PDIP and TO-99 rows in the same family, different strings |
The fabrication flow is a real variable on this part. The vendor qualifies more than one flow and labels the difference by chip site origin, and the two flows differ in bandwidth, offset and drift. A customer who qualified a channel at 500 kHz and receives parts from the other flow will see 200 kHz, and the channel that passed the first article may fail the production test. Naming the flow in a purchase order is the only way to hold the faster figure, and the flow is identified by the marking rather than by the order string.
Why a difference amplifier still beats an isolation amplifier
Above a few hundred volts of common mode, a conventional difference amplifier runs out of input range and the usual answer is galvanic isolation. This part is specified to 200 V of common mode with 500 V of protection, which covers most servo drives, machine tools, semiconductor testers and ultrasound scanners without an isolation barrier. Removing the barrier removes the isolated supply, and with it the ripple, the noise and the quiescent current that an isolated supply brings. The trade is that there is no galvanic separation, so a fault that puts thousands of volts on the input is not contained.
The 200 V figure is also a warning rather than a target. Operating at the top of the common mode range leaves no room for a transient, and a motor drive that produces a 400 V spike on the common mode will exceed the protection window. A divider in front is the usual answer, and it costs the gain accuracy that the internal network was trimmed to deliver.
The internal resistor network and what it buys
A discrete difference amplifier built from four resistors has a common mode rejection set by the resistor matching, and a 0.01 per cent match is about 86 dB. This part achieves 70 dB minimum with the network on the die, which is not better than a good discrete network and is far better than a typical one. The value of the integrated network is the matching over temperature and the long term stability, not the absolute rejection figure.
The long term drift of 200 µV per month is the specification that decides the calibration interval. A channel that starts at 120 µV of offset and drifts 200 µV a month will be outside a 1 mV budget within five months, which is a quarterly calibration rather than an annual one. A customer who specifies an annual calibration on this part is specifying something the data sheet does not support.
Unity gain and the absence of a gain resistor
The gain is fixed at one by the internal network, and there is no gain resistor to change it. That is a simplification and a limitation: a channel that needs a gain of 10 has to add an amplifier after this part, and the added amplifier brings its own offset and drift. Where the differential signal is large enough, the unity gain part is the cleaner solution, and where it is not, a high voltage difference amplifier with an adjustable gain is the other family to look at.
The reference pins at both ends of the network allow the output to be offset, which is how a bipolar input is mapped onto a unipolar converter. Driving both reference pins from the same source is necessary, because the network is symmetric and a difference between them appears as a differential error.
Buying INA117KU
The tube is 75 pieces and NRND, the reel is 2500 pieces and active, and the two strings have different end of life statuses. For a production build the reel is the row to quote, and for a repair or a prototype the tube is the convenient one. A customer who quotes the tube string for a new build is quoting a part the vendor has stopped recommending, even though the reel string of the same die is still active.
The sibling bodies matter as well. The family also ships in a plastic DIP and a TO-99, and some of those strings are last time buy. Substituting between bodies is a board change, so the body and the string have to be decided together.
Questions that arrive with this part number
The first is whether the part can measure a 500 V common mode. It cannot: the protection is 500 V and the linear range is 200 V. The second is which fabrication flow the customer has, and the answer is that the marking and the vendor's flow letter decide it, not the order string.
The third is whether the part can be replaced by a modern isolation amplifier. It can where the isolation is needed, and the modern part brings a barrier and its own supply requirements. Where the isolation is not needed, this part is simpler and quieter than any barrier.
For a customer working on a servo drive or a test system with a high common mode, our obsolete part cross reference hub lists the candidates, and the amplifier cross reference page sets out the parameters we compare before a substitution is quoted.
One further point on the supply: the single supply range of 10 to 30 V is wider than the dual range suggests, and a 24 V industrial rail sits inside it. A customer who runs the part from a single 24 V rail gets a common mode range that is referenced to that rail rather than to ground, and the reference pins have to be set accordingly. That is often the simpler arrangement in a servo drive, where the rail already exists and a plus or minus 15 V rail does not.