Contact Us

INA117KU

Brand: Texas Instruments
Texas Instruments INA117KU is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

INA117KU — Power Management & Signal Chain | Superb Automation

INA117KU

Texas Instruments — Power Management & Signal Chain

Product Overview

The INA117KU from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

INA117KU: a difference amplifier that takes 200 V of common mode

The INA117KU is a unity gain difference amplifier built around a precision operational amplifier and a thin film resistor network on the same die, and its purpose is to measure a small differential voltage sitting on a very large common mode. With plus or minus 15 V supplies the common mode input range is plus or minus 200 V, the inputs are protected against 500 V of common mode and differential overload, the gain error is 0.05 per cent maximum, and the nonlinearity is 0.001 per cent maximum. Common mode rejection is 70 dB minimum, and the bandwidth is 200 kHz or 500 kHz depending on which fabrication flow the die came from.

The status on this string is not recommended for new builds, and the tube row and the reel row disagree in a way that matters: the tube string is NRND while the slash two K five reel string is listed as active. A buyer who needs this part in production should quote the reel string rather than the tube, and should confirm the status with the vendor at the time of order.

The INA117KU rows as the addendum publishes them

Part classUnity gain difference amplifier, high common mode
Vendor statusNRND on the tube string, active on the reel string
Data sheetSBOS154C, revised January 2026
Common mode input rangePlus or minus 200 V with plus or minus 15 V supplies
Input protection500 V common mode and 500 V differential overload
GainUnity, fixed by the internal network
Gain error0.05 per cent maximum
Nonlinearity0.001 per cent maximum
Common mode rejection70 dB minimum
Bandwidth200 kHz on one fabrication flow, 500 kHz on the other
Offset voltage, one flow120 µV typical, 1000 µV maximum
Offset voltage, other flow350 µV typical, 1000 µV maximum
Offset drift, one flow8.5 µV per degree
Offset drift, other flow3 µV per degree
Long term drift200 µV per month
Supply, single10 V minimum, 30 V typical, 36 V maximum
Supply, dualPlus or minus 5 V to plus or minus 18 V
BodySOIC, D outline, 8 pins
Thermal resistance, SOIC150 degrees per watt junction to ambient
Carrier, tube row75 pieces in a tube, level 3 at 260 degrees
Carrier, reel row2500 pieces on a large tape and reel, level 3
Temperature rangeMinus 40 to plus 85 degrees
Part marking117KU
Sibling bodiesPDIP and TO-99 rows in the same family, different strings

The fabrication flow is a real variable on this part. The vendor qualifies more than one flow and labels the difference by chip site origin, and the two flows differ in bandwidth, offset and drift. A customer who qualified a channel at 500 kHz and receives parts from the other flow will see 200 kHz, and the channel that passed the first article may fail the production test. Naming the flow in a purchase order is the only way to hold the faster figure, and the flow is identified by the marking rather than by the order string.

Why a difference amplifier still beats an isolation amplifier

Above a few hundred volts of common mode, a conventional difference amplifier runs out of input range and the usual answer is galvanic isolation. This part is specified to 200 V of common mode with 500 V of protection, which covers most servo drives, machine tools, semiconductor testers and ultrasound scanners without an isolation barrier. Removing the barrier removes the isolated supply, and with it the ripple, the noise and the quiescent current that an isolated supply brings. The trade is that there is no galvanic separation, so a fault that puts thousands of volts on the input is not contained.

The 200 V figure is also a warning rather than a target. Operating at the top of the common mode range leaves no room for a transient, and a motor drive that produces a 400 V spike on the common mode will exceed the protection window. A divider in front is the usual answer, and it costs the gain accuracy that the internal network was trimmed to deliver.

The internal resistor network and what it buys

A discrete difference amplifier built from four resistors has a common mode rejection set by the resistor matching, and a 0.01 per cent match is about 86 dB. This part achieves 70 dB minimum with the network on the die, which is not better than a good discrete network and is far better than a typical one. The value of the integrated network is the matching over temperature and the long term stability, not the absolute rejection figure.

The long term drift of 200 µV per month is the specification that decides the calibration interval. A channel that starts at 120 µV of offset and drifts 200 µV a month will be outside a 1 mV budget within five months, which is a quarterly calibration rather than an annual one. A customer who specifies an annual calibration on this part is specifying something the data sheet does not support.

Unity gain and the absence of a gain resistor

The gain is fixed at one by the internal network, and there is no gain resistor to change it. That is a simplification and a limitation: a channel that needs a gain of 10 has to add an amplifier after this part, and the added amplifier brings its own offset and drift. Where the differential signal is large enough, the unity gain part is the cleaner solution, and where it is not, a high voltage difference amplifier with an adjustable gain is the other family to look at.

The reference pins at both ends of the network allow the output to be offset, which is how a bipolar input is mapped onto a unipolar converter. Driving both reference pins from the same source is necessary, because the network is symmetric and a difference between them appears as a differential error.

Buying INA117KU

The tube is 75 pieces and NRND, the reel is 2500 pieces and active, and the two strings have different end of life statuses. For a production build the reel is the row to quote, and for a repair or a prototype the tube is the convenient one. A customer who quotes the tube string for a new build is quoting a part the vendor has stopped recommending, even though the reel string of the same die is still active.

The sibling bodies matter as well. The family also ships in a plastic DIP and a TO-99, and some of those strings are last time buy. Substituting between bodies is a board change, so the body and the string have to be decided together.

Questions that arrive with this part number

The first is whether the part can measure a 500 V common mode. It cannot: the protection is 500 V and the linear range is 200 V. The second is which fabrication flow the customer has, and the answer is that the marking and the vendor's flow letter decide it, not the order string.

The third is whether the part can be replaced by a modern isolation amplifier. It can where the isolation is needed, and the modern part brings a barrier and its own supply requirements. Where the isolation is not needed, this part is simpler and quieter than any barrier.

For a customer working on a servo drive or a test system with a high common mode, our obsolete part cross reference hub lists the candidates, and the amplifier cross reference page sets out the parameters we compare before a substitution is quoted.

One further point on the supply: the single supply range of 10 to 30 V is wider than the dual range suggests, and a 24 V industrial rail sits inside it. A customer who runs the part from a single 24 V rail gets a common mode range that is referenced to that rail rather than to ground, and the reference pins have to be set accordingly. That is often the simpler arrangement in a servo drive, where the rail already exists and a plus or minus 15 V rail does not.