TPS25221DBVR

Brand: Texas Instruments
Texas Instruments TPS25221DBVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS25221DBVR — Power Management & Signal Chain | Superb Automation

TPS25221DBVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS25221DBVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS25221DBVR: adjustable current limited power switch, 2 A, 2.5 V to 5.5 V

TPS25221DBVR is an adjustable current limited power switch rated 2 A in a six pin SOT-23 in a SOT-23 body of 6 pins. The current limit is set by one resistor from 275 mA to 2.7 A, and at the higher settings the threshold is accurate to about 6 per cent, which is tight enough to protect a connector without derating the load. A short circuit is caught in 1.5 microsecond and reported after an 8 millisecond deglitch, so a hot plug event does not produce a spurious fault flag.

Order code and package

TPS25221DBVRActive, SOT-23-6, 3000 pieces on a large reel, NIPDAU finish, MSL-1
TPS25221DBVTActive, the same body, 250 pieces on a small reel
TPS25221DRVRActive, the WSON six pin body, 3000 pieces on a large reel
Pin to pin alternativeTPS2553, same footprint and the same limit resistor behaviour
Temperature rangeminus 40 to 125 degrees on every row

Electrical parameters that decide the application

Input voltage2.5 V to 5.5 V
Continuous current2 A
Adjustable limit275 mA to 2.7 A through a resistor from 20 k to 210 k
Limit accuracyplus or minus 6.5 per cent at 1.7 A
On resistance70 milliohm typical
Short circuit response1.5 microsecond
Fault deglitch8 millisecond
Reverse currentblocked while the switch is disabled

Family variants and how they differ

20 k resistor2585 to 2850 mA, the top of the range
30 k resistor1710 to 1930 mA
80 k resistorabout 755 mA
210 k resistorabout 275 mA, the bottom of the range
Soft startbuilt in, the ramp is controlled to limit the turn on surge

Points to check before this part goes on a BOM

The limit is set by a resistor and the table is not linear. 20 k gives about 2.72 A, 30 k gives about 1.82 A, 80 k gives about 755 mA and 210 k gives about 275 mA. Between those points the curve is not a straight line, so a value picked by interpolation will land somewhere else. The table in the data sheet is the reference, and the resistor tolerance adds to the 6.5 per cent of the part.

6.5 per cent accuracy is the tightest point of the range. The figure belongs to the 1.7 A setting. At the low end the same part is looser, so a 275 mA limit can be a noticeably different current from unit to unit. Where the limit has to protect a small connector, the accuracy at that setting has to be read from the table rather than assumed from the headline.

8 millisecond deglitch is what keeps the fault pin useful. Without it, the inrush into a capacitive load would trip the fault output on every plug in, and firmware would report a fault on a healthy port. The 1.5 microsecond short circuit response still acts immediately on the current, so the delay applies to the report and not to the protection.

Reverse current blocking while disabled is not the same as reverse protection. With the switch off the body diode is blocked, so a load cannot back feed the input. With the switch on, current can flow both ways through the channel. A load that can source current into the rail needs a different part or an external diode, and this distinction is where most hot swap mistakes start.

70 milliohm at 2 A is 280 mV of drop. That is 0.56 W inside the switch, in a six pin body, and it is the reason the current rating comes with a thermal condition. A USB port that delivers 2 A continuously into a device in a sealed enclosure is running this part near its thermal limit even though the electrical rating is met.

UL recognition matters on a port a user can touch. The part is recognised to UL 60950 and UL 62368, and the 15 kV contact discharge figure under IEC 61000-4-2 needs the external capacitor shown in the data sheet. Both of those are system level claims, and the certificate belongs to the arrangement that was tested, not to the part on its own.

The 2 A rating is a continuous current, not a limit. The limit resistor is set above the load current, not at it. A 2 A load with a 2.2 A limit leaves only 10 per cent of headroom, and a load that draws a surge on start up will sit in constant current mode. The usual margin is 30 to 50 per cent above the steady load, which is why the range goes to 2.7 A on a 2 A part.

The ILIM pin is sensitive to noise and to board leakage. The pin sits at a low voltage and sets the limit with a resistor to ground, so any leakage into the node changes the threshold. Flux residue on a board that was not cleaned adds to that leakage and shifts the limit, which is why a port that fails incoming test at the limit value is often a cleaning problem rather than a part problem. Keep the resistor close to the pin and keep the node short.

A 5 V port and a 3.3 V port can share the same limit. The connector rating is a current and the resistor enforces it, so two ports that share a connector type but run at different voltages can share the same resistor, which simplifies the bill of material, provided the connector is rated for the higher of the two voltages.

The deglitch also hides a fast trip from firmware. A firmware health check that reads the fault pin once a second misses an 8 millisecond event entirely, so a port that faults and recovers repeatedly shows nothing on the pin. Counting current in the load is the only way to see those events.

What to check on a current limited port

The resistor value against the connector rating, not against the load. The connector is the part that cannot be replaced in the field, and the limit exists to protect it.

The fault pin pull up and its logic level, because the output is open drain and a 5 V pull up on a 3.3 V processor pin is a common and avoidable failure.

Where this order code fits

It current limits a USB port or a hot swap slot at 2 A and reports the fault, so a shorted cable does not take the main rail down. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

How accurate is the current limit in practice? About 6.5 per cent at 1.7 A and looser at the low end of the range. Add the resistor tolerance, and a 1 per cent resistor gives a total window of about 7.5 per cent, which is normally enough to protect a connector without cutting into the load current.

Does it need an external capacitor for the ESD rating? Yes. The 15 kV contact discharge figure under IEC 61000-4-2 is quoted with the external capacitance fitted as shown in the data sheet application circuit. Without it the port is not protected to that level.

What happens to the load during a short? The switch enters constant current mode at the set limit, so the load current is held rather than cut. The fault output asserts after 8 millisecond. A sustained short therefore keeps the part in a current limited state until the short clears or the thermal protection acts.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.