INA116PA
Product Specifications
INA116PA
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA116PA from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA116PA: the femtoamp bias current amplifier in a 16 pin plastic DIP
The INA116PA is a monolithic FET input instrumentation amplifier built for one specification above all others: input bias current. The vendor publishes 3 fA typical at 25 degrees and 25 fA at 85 degrees, which is three to four orders of magnitude below a conventional FET input amplifier, and it is achieved with Difet inputs and a guarding arrangement that includes buffered guard drive pins next to each input. The rest of the specification is modest by comparison: 2 mV of maximum offset, 84 dB of common mode rejection at a gain of 10, 1 mA of quiescent current, 40 V of input protection, and a gain range from 1 to 1000 on a single resistor.
The status on the addendum is the first thing a buyer needs to know. This string is Last Time Buy, which means the vendor has published a final order window and the part will not be built again. A programme that has this amplifier in a pH or ion selective probe channel is looking at a board change, a lifetime buy, or both, and the arithmetic of that decision is different from a normal sourcing question.
The INA116PA rows as the addendum publishes them
| Part class | FET input instrumentation amplifier, ultra low bias current |
| Vendor status | LAST TIME BUY on this string |
| Data sheet | SBOS034 |
| Input bias current at 25 degrees | 3 fA typical |
| Input bias current at 85 degrees | 25 fA typical |
| Input offset voltage | 2 mV maximum |
| Common mode rejection at G = 10 | 84 dB |
| Quiescent current | 1 mA |
| Input overvoltage protection | 40 V without damage |
| Gain equation | G = 1 + 50 kΩ divided by RG |
| Gain range | 1 to 1000 V/V |
| Guard pins | Buffered guard drive at both inputs, for board and cable guards |
| Body | PDIP, N outline, 16 pins |
| Carrier | 25 pieces in a tube |
| RoHS | Yes |
| Lead finish | Nickel palladium gold |
| Moisture level | Not applicable to this package type |
| Temperature range | Minus 40 to plus 85 degrees |
| Part marking | INA116PA |
| Revision row | INA116PA.A, listed as production while the plain row is last time buy |
| Sibling string | INA116UA in the SOIC body, marked NRND |
| Quantity note | 25 pieces per tube is a small carrier for a lifetime buy |
The 25 piece tube is the detail that makes a lifetime buy awkward. A programme that needs five thousand pieces is buying two hundred tubes, and two hundred tubes of an obsolete part is a storage, a bake and a counting exercise. The alternative is a distributor holding the stock, which is what a lifetime buy through a supply partner is for, and it moves the counting problem to the partner rather than removing it.
What 3 fA means in practice
Three femtoamps into a 10^12 Ω source is 3 mV of offset, and into 10^14 Ω it is 300 mV, which is why the part exists for pH electrodes and ion selective probes rather than for general instrumentation. The bias current is not the only term at those impedances: board leakage, cable leakage, connector leakage and humidity all contribute, and the amplifier is only the smallest of them if the guard is done properly. A fingerprint on the board between the input and a neighbouring trace is nanoamps, which is a thousand times the amplifier's own bias current.
The guard pins are the mechanism that keeps the board leakage from mattering. They sit adjacent to the inputs and carry a buffered copy of the input voltage, so the voltage across the leakage path to the guard is nearly zero and the current through it is nearly zero with it. The guard has to surround the input trace on both sides and, ideally, on the layer below, and the cable guard has to be driven from the same pin rather than grounded.
Guarding a cable, not just a board
A pH probe cable is a few metres of high impedance path, and its insulation resistance is the limit on the whole channel. A driven guard around the inner conductor raises the effective insulation resistance by the gain of the guard buffer, and a grounded shield lowers it by offering a low impedance path to ground. That is the opposite of what a conventional low noise cable does, and it is the single most common mistake on a high impedance channel.
The guard buffer inside the part is specified for the job, so the guard pin can drive a cable shield of a few hundred picofarads without instability. Above that, a series resistor in the guard line is the usual fix, at the cost of a slower guard settling after a step.
Last time buy arithmetic
The decision on a last time buy has three inputs: the remaining product life, the annual consumption, and the cost of a board change. A programme with five years left at two hundred pieces a year needs a thousand pieces, which is forty tubes, and the storage cost over five years is trivial compared with a board change. A programme with fifteen years left at the same rate needs three thousand pieces, and the storability of a plastic DIP over fifteen years is the question that decides the case.
Plastic packages absorb moisture and the leads oxidise, and a fifteen year store is not a datasheet condition. A dry cabinet and a nitrogen blanket extend the window, and a periodic solderability check on a sample tube is the way to know where the stock stands. Where the product life is long, the board change is usually the cheaper route even when the lifetime buy looks cheaper on the first quotation.
Buying INA116PA
This string is last time buy and the sibling in the SOIC body is not recommended for new builds, so the supply is finite and the price reflects it. A buyer should ask three questions before quoting: how many pieces the vendor still holds, what the final order date is, and whether the parts are on the shelf or on the water. A quoted lead time on a last time buy part is often a promise rather than a schedule.
For a customer who needs the part now, a broker with a photographed tube label, a date code and a country of origin is the only acceptable source. For a customer who needs it for ten years, the honest answer is that this part is the wrong choice and a board change is the project.
Questions that arrive with this part number
The first question is whether the 3 fA figure can be met on a normal board. It cannot; the board leakage will be larger, and the guard has to be part of the board before the figure means anything. The second is whether the part can be replaced by a modern electrometer amplifier. It can, and the modern part is usually smaller and cheaper, but the pin out and the guard arrangement differ and the board change is the work.
The third is whether the SOIC sibling is the same die. It is, in a different package and with a different status, which is why the two are not interchangeable in a lifetime buy plan.
For a programme facing a last time buy, our last time buy planning page sets out the arithmetic, and the obsolete part cross reference hub lists the families we compare when a part is discontinued.
A note on the guard and the cleaning process: an aqueous wash leaves ionic residue under a component that a solvent wash does not, and on a femtoamp channel that residue is the dominant leakage path. The part should be washed, dried and coated before it is powered for the first time, and the coating should cover the guard ring as well as the input traces so that humidity cannot bridge the two.
The connector is the other leak. A plastic connector body absorbs moisture, and a channel that measures correctly in a dry room and drifts in a humid one is showing the connector rather than the amplifier. A hermetic connector, or a conformal coat over the connector pins, is the fix, and it is cheaper than a better amplifier.