BQ7697202PFBR
Product Specifications
BQ7697202PFBR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ7697202PFBR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ7697202PFBR: sixteen series battery monitor and protector with a high side charge pump in a forty eight pin TQFP
BQ7697202PFBR is a battery monitor and protector for three to sixteen series cells that measures cell voltage, pack current and temperature and drives high side protection FETs in a TQFP body of 48 pins. The device carries two independent converters, so cell voltage and pack current are sampled at the same moment, and an integrated charge pump drives high side N channel protection FETs. The 02 suffix selects the I2C variant with the first regulator set to 3.3 V.
Order code and package
| BQ7697202PFBR | TQFP PFB, 48 pins, 1000 pieces on a large reel, marking BQ7697202 |
| BQ7697204PFBR | same body and reel, I2C variant with the regulator default set the other way in the comparison table |
| BQ76972PFBR | the SPI disabled member of the same family, same body and reel |
| Moisture level | Level 2, 260 C, one year floor life |
| Temperature | minus 40 to plus 85 C ambient on every published row |
| Supply | pack input from the top of the stack, with the part powered from the cells it monitors |
| Regulators | two programmable LDOs, the first defaulting to 3.3 V on the 02 row, for external system loads |
Electrical parameters that decide the application
| Cell range | 3 series to 16 series cells, Li-ion, Li-polymer and LiFePO4 chemistries |
| Cell accuracy, 25 C | minus 1.8 mV to plus 1.8 mV with fixed offset adjustment over a 2 V to 3.7 V cell window |
| Cell accuracy, calibrated | minus 1.0 mV to plus 1.0 mV at 25 C once cell offset calibration has been run |
| Cell accuracy over temperature | minus 3.8 mV to plus 4.5 mV from minus 20 C to plus 65 C on the fixed offset rows |
| Coulomb counter | 16 bit, plus or minus 200 mV across the sense resistor, offset drift 0.03 LSB per C after calibration |
| Current sense range | plus or minus 200 mV across the sense resistor, which sets the shunt value for the pack current |
| Interface | 400 kHz I2C, SPI and HDQ one wire, all on the same pins through a multiplexer |
| Protection inputs | cell overvoltage and undervoltage, two thermistor channels, pack current, and internal diagnostics |
Family variants and how they differ
| BQ76972 | the base member, I2C enabled with the SPI option disabled in the comparison table |
| BQ7697202 | the row on this page, I2C with the first regulator default set to 3.3 V |
| BQ7697204 | a further I2C member of the same body, listed beside the 02 row in the device comparison table |
| Protection drive | high side N channel FETs through the charge pump, with an optional autonomous recovery path |
| Balancing | internal cell balancing that runs while the pack is charging or at rest, controlled by the host or autonomously |
| Second life | the same part is used as a monitor only, with the protection outputs left unconnected in a pack that has its own protector |
Points to check before this part goes on a BOM
The two converters are the reason the part is usable on a load with a moving current. If cell voltage and pack current are measured at different times, the internal resistance of the pack shows up as an error in the cell voltage during a load step. Sampling them together removes that error without a correction table in the host.
The accuracy figures carry a condition that is easy to lose in a datasheet summary. The 1.8 mV window applies at 25 C with fixed offset adjustment already applied, and the window widens to 4.5 mV once the whole minus 20 to plus 65 C range is included. A specification quoted at 1.8 mV for a product that runs outdoors is optimistic.
Cell offset calibration is a production step, not a firmware feature. The routine needs a stable reference applied to every cell input in turn, which means a fixture with sixteen accurate sources. Where that fixture does not exist, the 1.8 mV row is the number that applies.
The coulomb counter needs a shunt whose thermal drift is smaller than the accuracy target. At plus or minus 200 mV of sense range, the resolution of a 16 bit converter is fine, but a shunt with 50 ppm per C drift moves the reading by more than the converter error over a 60 C swing. The shunt, not the converter, sets the pack accuracy.
The high side charge pump removes the need for a level shifter on the protection FETs. Low side protection puts the FETs in the pack return, where a chassis short can bypass them. High side protection keeps the return intact, which is why telecom and medical packs ask for it, and the charge pump is what makes the gate drive possible without a separate rail.
Autonomous recovery has to be chosen deliberately. A pack that recovers by itself after an over current event will re energise the output without a host decision. That is right for a cordless tool and wrong for a pack that has to stay latched off until a service technician clears the fault.
What the host has to do at start up
The host reads the device status, clears any latched fault, and writes the protection thresholds before the pack is allowed to close its FETs. A pack that closes first and configures afterwards will pass a short circuit event with the factory thresholds, which are not the ones the product needs.
The second step is the current path calibration. The offset of the coulomb counter is measured with no load and written back, and that single number is what keeps the state of charge from drifting over a week of standby.
Where a sixteen cell monitor earns its cost
A pack that runs a single monitor per sixteen cells needs one isolated communication path per stack section, and that path is the expensive part of a high voltage pack. Using the full sixteen channels keeps the number of sections, and therefore the number of isolators, at the minimum.
The second saving is the sense harness. Sixteen cell taps have to reach the monitor with equal wire length and a filter on each tap, and a part with an internal multiplexer and open wire detection turns a harness fault into a readable status bit instead of an unexplained measurement offset.
Where this order code fits
Energy storage cabinets, battery backup units for telecom sites, e-bikes and light electric vehicles, cordless power tools and garden equipment, and non military drones. In each case the pack has between three and sixteen cells, a protection FET path that has to be high side, and a host that wants a single bus for voltage, current and temperature. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Medical Device Components page.
Questions buyers ask
Does the part protect the pack by itself? It measures and it drives the protection FETs, and the thresholds are programmable, so with the autonomous settings it will open the FETs on an overvoltage, undervoltage, overcurrent or overtemperature event without the host. The host is still needed for balancing strategy and for recording the event.
How many thermistors can be watched? Two thermistor channels are brought out as TS1 and TS2, and further pins can be configured as thermistor inputs or as general purpose ADC inputs. A pack with four temperature sensors therefore uses the two dedicated pins and two multifunction pins.
What shunt value does a 100 A pack need? With plus or minus 200 mV of sense range, a 100 A full scale needs a 2 milliohm shunt. That dissipates 20 W at full current, which is why high current packs use a smaller shunt and accept a lower sense voltage, trading resolution for heat.
Can the same part be used on a 48 V pack and a 60 V pack? Yes, up to sixteen series cells, which covers both. The cell count is set by how many VC pins are connected, and the top of the stack is the supply, so the pack voltage follows the cell count rather than a separate rail.
Is the I2C address fixed? The address is set by the part, so two devices on the same bus need a multiplexer or a separate bus. In a pack that uses one monitor this does not matter, and in a system with several packs it decides the bus topology.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Component Obsolescence Management page sets out the checks that keep a substitute from failing on the bench.