Contact Us

BQ34210IPWRQ1

Brand: Texas Instruments
Texas Instruments BQ34210IPWRQ1 is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

BQ34210IPWRQ1 — Power Management & Signal Chain | Superb Automation

BQ34210IPWRQ1

Texas Instruments — Power Management & Signal Chain

Product Overview

The BQ34210IPWRQ1 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

BQ34210IPWRQ1: a gauge for a battery that is almost never used

The BQ34210IPWRQ1 is a single cell fuel gauge built for the opposite case to a phone. It is meant for a battery that sits on charge for months and is only called on when the main supply fails, which is the pattern in an eCall module, a telematics backup unit or an uninterruptible supply for a small load. For that pattern the useful question is not how much charge is left, it is whether the battery can still deliver the current the system needs for the seconds or minutes it has to run.

The part answers that with Compensated End of Discharge modelling. It reads cell voltage, current and temperature, and it reports state of charge, time to empty and state of health. Alongside those it runs an end of service test: it applies a known load, watches the cell voltage sag under it, and decides whether the cell still has the capability the system assumes. A cell that reads 90 per cent state of charge but collapses under a 2 A pulse will fail that test, which is the failure a plain voltage check never sees.

The package is a 14 pin TSSOP at 5.00 mm by 4.40 mm, and the part runs from the battery through its own regulator. It carries an AEC-Q100 Grade 3 qualification and its orderable row is rated minus 40 to 85 C. Current is measured across a 10 milliohm sense resistor, and the sense point can be placed high side or low side.

Key data for the BQ34210IPWRQ1

FunctionSingle cell system side fuel gauge with end of service test
AlgorithmCompensated End of Discharge, no full cycle needed to start reporting
ChemistriesLi-ion, LiFePO4, and three cell NiMH
Current sense10 milliohm external resistor, high side or low side placement
ReportsState of charge, time to empty, state of health, end of service warning
InterfaceI2C at 400 kHz, configurable alert output
Normal current50 microamps typical
Sleep current9 microamps typical
Load enableLoad enable pin lets the host apply the test load for the end of service check
QualificationAEC-Q100 Grade 3, minus 40 to 85 C
PackageTSSOP, 14 pins, 5.00 mm by 4.40 mm, 1.00 mm body height
OrderingBQ34210IPWRQ1, 2000 pieces on a large tape and reel, moisture level 3 at 260 C with a 168 hour floor life, marking BQ34210I

Why the end of service test matters more than the gauge

A backup battery spends its life near full charge, at a temperature set by the enclosure, and it is asked for a real load perhaps twice in its life. That is a hard life for a lithium cell, because calendar ageing at high state of charge is what removes capability, not cycling. After four years the gauge may still read a high state of charge while the internal resistance has risen enough that the cell cannot hold the rail under a pulse.

The end of service test is built for exactly that. The host asserts the load enable pin, the part switches in a load, measures the sag, and compares it against the threshold that was written for the product. The comparison is made against a capability number rather than a capacity number, so the warning comes before the module fails in the field rather than after.

The catch is that the test itself costs charge, and on a sealed module with no charger that charge is not coming back. A service interval that runs the test every month will shorten the life of the very battery it is checking. Most programmes run it at a long interval, or only when the module is on the bench, and the interval is one of the first things to agree with the system owner.

The sensing arrangement, and why it is the usual source of error

A 10 milliohm resistor at 1 A drops 10 mV. The part has to resolve that against a common mode that sits at the pack voltage, and it has to do it without the trace resistance between the resistor and the sense pins adding to the reading. The kelvin connection is not optional here: the two sense traces have to meet the resistor pads at the edge of the pad, not somewhere along the current path.

Placement matters as much as routing. A high side sense resistor sees the full pack voltage on both pins and the part has to level shift it, which is what the high side option in this device exists for. A low side resistor sits near ground and is easier to route, but it moves the pack return off the system ground, and any load that shares that return will corrupt the reading while it is switching.

The last item is the resistor itself. A 1 per cent part with a 100 ppm temperature coefficient is a reasonable choice; a 5 per cent part is not, because the error lands directly on every current and capacity number the gauge reports and there is no calibration step in the part that can remove it.

Where it fits in a build

Any product with a single backup cell that has to be trusted after years of standby is the target: eCall and telematics modules, alarm panels, medical carts with a backup battery, remote assets that report after a mains failure. A product that cycles its battery daily, such as a handheld tool, is a poor fit because the end of service test is built for the standby case and the part is configured around it.

These modules are also built in small volumes across several years, so the reel often has to be split. On a split reel the date code management page covers how reel age is tracked and what we will not ship into a new build.

The sourcing side of this part is covered on the incoming inspection plan. For a gauge whose thresholds set a safety case, that page covers the checks we run at the receiving dock.

Questions we get on this code

Does the gauge need a learning cycle before it reports a state of charge? No. The model is written from cell data at the pack house, and the part starts reporting from the first reading. What it does need is the correct chemistry profile and the correct sense resistor value loaded into its configuration.

Can it run on NiMH as well as lithium? Yes, the part supports three cell NiMH as well as single cell lithium chemistries. The model and the end of service thresholds are different, so the configuration is not shared between the two.

How often should the end of service test run? Long enough that the test does not dominate the battery budget, short enough that a failing cell is caught inside the service interval. On most modules that lands between every few months and once a year, and the number has to come from the load profile rather than from the data sheet.

What happens if the sense resistor is the wrong value? Every current, capacity and state of health number scales with it, and the end of service test compares against a threshold that is no longer meaningful. It is the one configuration item to confirm on the first build of any new board.