Isolated Gate Drivers and SiC Gate Drive Supplies
Product Specifications
Product Overview
An isolated gate driver does two jobs that a level shifter cannot: it moves the drive signal across a safety barrier, and it lets the high side gate sit on a source that swings with the switching node. The barrier is inside the package, built from a transformer or a capacitor pair on a silicon die, so the creepage that matters is the package creepage and the slot milled under it, not the clearance between two separate parts. The rating that goes on the quotation is the one with the standard behind it: 2.5 kV rms for one minute per UL 1577 on the Si827x family, 5 kV ac for one minute on the ADuM4135, and 5.7 kV rms reinforced on the UCC21520, which also carries an 8 kV peak transient figure for the component level standard.
The peak current decides the gate resistor, and the gate resistor decides the switching loss. A 4 A source and 6 A sink part can charge a 100 nC gate to 15 V in about 25 ns, which keeps a 20 kHz bridge in the safe part of its safe operating area and still leaves the turn on slow enough to hold the drain voltage ringing down. A part with 1 A of drive cannot do that, and the loss moves into the die. The current figure is a peak pulse rating, not a continuous one, so it is paired with the total gate charge and the switching frequency when the thermal budget is checked.
Propagation delay and its matching matter more than the absolute number in a bridge. The UCC21520 quotes 33 ns typical delay with 6 ns maximum pulse width distortion and 5 ns channel to channel matching, which is what keeps a half bridge from shoot through when the dead time is programmed short. The Si827x family quotes 60 ns maximum delay with 200 ps jitter, and the ADuM4135 quotes 55 ns typical with a 50 ns minimum pulse width. When two channels of different parts are used in one bridge, the matching between them, not the delay, is what sets the minimum safe dead time.
Protection is where the single channel IGBT and SiC parts earn their price. A desaturation detector watches the collector or drain voltage during on time, and if the switch does not pull down within a blanking window the driver reports a fault across the barrier and turns the gate off slowly, which limits the current that a hard short would otherwise interrupt. The ADuM4135 adds a Miller clamp: below 2 V of gate voltage a second low impedance path holds the gate down, so a fast dv/dt on the drain cannot push the gate back up through the Miller capacitance and turn the switch on again. That clamp is what lets a single rail supply be used instead of a negative rail.
The table below covers the parts we quote most often for motor drives, solar and charger stages, and the small transformer driver that generates the isolated bias on the secondary side. Isolation rating, peak current, delay, supply, UVLO and package come from the maker data sheet for each part number.
Key Specifications
| Parameter | Single channel IGBT, ADuM4135 | Dual channel, UCC21520 | Single and half bridge, Si827x |
|---|---|---|---|
| Isolation rating | 5 kV ac for 1 minute per UL 1577, 849 V peak working | 5.7 kV rms reinforced, 8 kV peak transient | 2.5 kV rms for 1 minute per UL 1577 |
| Channels | 1 | 2, configurable as dual low side, dual high side or half bridge | 1 on Si8271, half bridge on Si8273, dual on Si8275 |
| Peak output current | 4 A, output resistance under 1 ohm | 4 A source, 6 A sink | 4 A source and sink |
| Propagation delay | 55 ns typical, 50 ns minimum pulse width | 33 ns typical, 6 ns maximum pulse width distortion | 60 ns maximum, 200 ps jitter |
| Common mode transient immunity | 100 kV per microsecond | Above 125 V per nanosecond | 400 kV per microsecond latch up immunity |
| Input supply | 2.3 V to 6 V | 3 V to 18 V | 2.5 V to 5.5 V |
| Output supply | 12 V to 30 V | Up to 25 V, UVLO options at 5 V and 8 V | 4.2 V to 30 V, UVLO options at 3, 5, 8 and 12 V |
| Protection | Desaturation detection, soft shutdown, Miller clamp, isolated fault and ready | UVLO, disable pin, programmable dead time | UVLO with driver shutdown, overlap protection on the half bridge |
| Package | Wide body SOIC-16, 7.8 mm creepage | Wide body SOIC-16 | SOIC-8, SOIC-16 or LGA-13 |
| Temperature | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C |
Included Models and Order Codes
The table lists the order codes we quote most often for IGBT, SiC and MOSFET bridges, plus the transformer driver used to build the isolated bias. Isolation rating, channels, peak current, delay, supply and package come from the maker data sheet for that code. The letters after the family name carry the UVLO threshold and the package, so Si8271AB and Si8271DB are not interchangeable even though the pin out is the same.
| Part Number | Channels | Isolation | Peak current | Delay | Output UVLO | Package |
|---|---|---|---|---|---|---|
| ADuM4135BRWZ | 1, with desaturation and Miller clamp | 5 kV ac, 849 V peak working | 4 A | 55 ns typical | 11.67 V typical secondary | SOIC-16 wide, 7.8 mm creepage |
| Si8271AB-IS | 1 | 2.5 kV rms | 4 A | 60 ns maximum | 5 V | SOIC-8 |
| Si8271GB-IS | 1 | 2.5 kV rms | 4 A | 60 ns maximum | 3 V | SOIC-8 |
| Si8271DB-IS | 1 | 2.5 kV rms | 4 A | 60 ns maximum | 12 V | SOIC-8 |
| Si8273AB-IS1 | 2, high side and low side | 2.5 kV rms | 4 A | 60 ns maximum | 5 V | SOIC-16 |
| Si8275AB-IS1 | 2, dual | 2.5 kV rms | 4 A | 60 ns maximum | 5 V | SOIC-16 |
| Si8274GB4-DIS1 | 2, high side and low side, PWM input | 2.5 kV rms | 4 A | 60 ns maximum | 3 V | SOIC-16, 20 to 700 ns dead time |
| UCC21520DW | 2, universal | 5.7 kV rms reinforced | 4 A source, 6 A sink | 33 ns typical | 5 V and 8 V options | SOIC-16 wide |
| UCC21520ADW | 2, universal | 5.7 kV rms reinforced | 4 A source, 6 A sink | 33 ns typical | 5 V and 8 V options | SOIC-16 wide |
| SN6505BDBVR | Transformer driver for isolated bias | Set by the transformer | 1 A drive at 5 V | Not applicable | 2.25 V to 5.5 V input | SOT-23-6 |
Key Features
Barrier rating quoted with its standard – 2.5 kV rms per UL 1577, 5 kV ac per UL 1577 and 5.7 kV rms reinforced are different claims, and the quotation states which standard each figure belongs to.
Miller clamp for single rail turn off – the ADuM4135 holds the gate below 2 V with a second low impedance path, so a fast drain transient cannot turn the switch back on and a negative rail is not needed.
Desaturation blanking written down – the desaturation comparator is masked for the first 300 ns to 370 ns of each on time, which is what stops the turn on spike from being read as a short circuit.
Delay matching, not just delay – 5 ns channel to channel matching on the dual channel part is what allows a short dead time to be programmed without shoot through.
Four UVLO grades on one pin out – the Si827x family offers 3, 5, 8 and 12 V output UVLO in the same package, so the same board can drive a logic level MOSFET or a 15 V IGBT gate.
Isolated bias from a small driver – the SN6505B drives a centre tapped transformer from 2.25 V to 5.5 V and delivers 1 A, which builds the secondary rail that the isolated driver needs.
Applications
These parts are quoted for products that switch a high voltage rail, typically where:
Motor drives and inverters – three half bridge channels drive a three phase bridge, and the 2.5 kV barrier keeps the control ground away from the switching node while the desaturation protection catches a shorted winding.
Solar, charger and power supply stages – a SiC totem pole or a phase shifted full bridge needs a driver with a fast delay and a tight match, and the isolated bias is built with the transformer driver on the same board.
Battery and traction auxiliaries – an isolated driver keeps the logic side referenced to the low voltage battery while the gate side sits on the high voltage bus, which is what the creepage and the barrier rating are there for.
The driver and its isolated bias sit on the power board next to the bridge, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that assembly.
Sourcing and Cross-Reference
Selection starts with the barrier. The working voltage across the isolation, the transient the standard requires and the pollution degree of the enclosure set the part family, and the package creepage has to be checked against the slot in the board rather than assumed from the rating alone. A 2.5 kV rms part and a 5.7 kV rms part can sit in the same footprint family and still not be interchangeable for a given clearance requirement.
The second check is the gate loop. Peak current, total gate charge, switching frequency and the allowed rise time give the gate resistor, and the resistor plus the loop inductance set the ringing that the desaturation blanking has to ignore. A driver with a fast delay and a slow turn off is not a contradiction: turn on is set by the source current and turn off by the sink current, and the two are chosen independently on the parts that have separate pull up and pull down outputs.
Where a specific code is short or has been marked not recommended for new builds, the replacement is checked on isolation rating, channel count, peak current, UVLO grade, delay and package at once. A part that matches the pins but not the UVLO threshold will turn on into an undervalued gate and fail in the field, and a part that matches the current but not the creepage will fail the safety review. The route for that comparison is on our source obsolete components page, and the drop in check is on how to verify a drop in replacement.
For volume builds, SUPERB Assembly support covers the barrier slot, the creepage under the package, the gate loop return and the transformer footprint of the isolated bias.
Q: Can you confirm the UVLO grade and the creepage of Si8271AB-IS, and quote a 5.7 kV rms dual channel alternative in the same footprint family?
A: Yes. Send the bus voltage, the switch type, the gate charge and the switching frequency, and the SUPERB Tech team will confirm the isolation rating, the peak current and the dead time from the maker data sheet before quoting.
Why Buyers Source Isolated Gate Drivers Through SUPERB
- Isolation figure tied to its standard: the quotation states whether a number is UL 1577 one minute, reinforced working voltage or a peak transient, so the safety file can cite it directly.
- UVLO grade named in the code: the letter that sets the UVLO threshold is shown on every line, which is the character that most often gets lost between a sample and a production order.
- Protection features listed separately: desaturation, soft shutdown, Miller clamp and fault reporting are listed as features, not folded into a single claim about robustness.
- Bias supply quoted with the driver: the transformer driver is offered with the isolated driver, because a driver without a secondary rail does not switch anything.
Related Product Families