Isolated DC-DC Modules and Brick Converters for Instrument Boards
Product Specifications
Product Overview
An isolated rail is chosen for one of three reasons: a floating measurement front end that must not share a ground with the digital side, a communications port that has to survive a several kilovolt surge, or a gate drive stage that needs a supply referred to the source of a switching device. In all three cases the module is a small encapsulated converter with a transformer inside, a specified isolation voltage, and a datasheet that states what happens at the barrier over time. The choice between a 1 W SIP part and a 20 W chassis part is mostly about how much power the floating side really needs and how much ripple the analogue circuit will tolerate.
The low power group is the 1 W to 3 W range: the Murata MEE1 and MEJ1 single output parts, the NMA and NME dual and single output parts, the Recom R1SE and R2S families, and the Traco TMR 2 and TMR 3, which come in a SIP-8 body with a 2 to 1 input range, 1600 VDC isolation, remote on and off and indefinite short circuit protection. These are the parts that sit next to an RS-485 transceiver, an isolated amplifier or a small gate driver, where 100 to 400 mA at 5 V or 12 V is the whole load.
Above that, the 15 W and 20 W modules and the brick converters cover instrument boards with several isolated channels or an intermediate bus. The Traco TEN 20 and THN 15 families give 15 W and 20 W in 1 x 1 inch and 2 x 1 inch footprints with 2 to 1 input ranges, and the Vicor Maxi and Mini bricks give several hundred watts at 24 V input for rack instruments and backplanes. On all of these, the isolation voltage is a test voltage rather than a continuous working voltage, and the datasheet states the creepage and the pollution degree the barrier is rated for, which is what a safety review asks about.
Key Specifications
| Parameter | 1 W to 3 W modules | 15 W to 20 W modules | Brick converters |
|---|---|---|---|
| Input range | 4.5 V to 5.5 V, or 2 to 1 wide range on the TMR family | 9 V to 36 V, 2 to 1 | 18 V to 36 V nominal 24 V, or 300 V input families |
| Output | 3.3 V, 5 V, 12 V, 15 V, plus or minus 5 V and plus or minus 12 V dual | 5 V, 12 V, 15 V, 24 V single and dual | 5 V to 48 V, single output |
| Power | 1 W, 2 W and 3 W | 15 W and 20 W | 200 W to 400 W in the Maxi and Mini sizes |
| Isolation | 1 kVDC, 1.6 kVDC, 3 kVDC and 5.2 kVDC depending on family | 1.5 kVDC to 3 kVDC | 1.5 kVDC to 3 kVDC, with the barrier specified for the module |
| Regulation | Unregulated on the 1 W parts, regulated on the 2 W and 3 W wide input parts | Regulated, plus or minus 1 percent | Regulated with remote sense on the brick |
| Efficiency | 70 to 80 percent at full load | 82 to 88 percent | 88 to 92 percent |
| Protection | Short circuit protection, some families indefinite | Overload, overvoltage and thermal | Overvoltage, overcurrent and thermal shutdown |
| Package | SIP-4, SIP-8, DIP and SMD | 1 x 1 inch and 2 x 1 inch | Quarter, half and full brick |
| Temperature | Minus 40 C to +85 C, derated above 70 C | Minus 40 C to +85 C | Minus 40 C to +100 C at the baseplate |
Included Models and Order Codes
The table lists the module order codes most often quoted for instrument boards. State the input rail, the output voltage and current, the isolation voltage the safety review requires, and the footprint you can accept, and the order code is confirmed with the packing.
| Part Number | Power | Input | Output | Isolation | Package |
|---|---|---|---|---|---|
| MEE1S0505SC | 1 W | 4.5 V to 5.5 V | 5 V at 200 mA | 1 kVDC | SIP-4 |
| MEE1S1205SC | 1 W | 10.8 V to 13.2 V | 5 V at 200 mA | 1 kVDC | SIP-4 |
| MEJ1S0505SC | 1 W | 4.5 V to 5.5 V | 5 V at 200 mA | 5.2 kVDC | SIP |
| NMA0505SC | 1 W | 4.5 V to 5.5 V | Plus and minus 5 V at 100 mA | 1 kVDC | SIP |
| R1SE-0505/H2 | 1 W | 4.5 V to 5.5 V | 5 V at 200 mA | 3 kVDC | SMD |
| R2S-0505 | 2 W | 4.5 V to 5.5 V | 5 V at 400 mA | 1 kVDC | SIP |
| TMR 2-2411 | 2 W | 18 V to 36 V | 5 V at 400 mA | 1600 VDC | SIP-8 |
| TMR 3-2411WI | 3 W | 9 V to 36 V | 5 V at 600 mA | 1600 VDC | SIP-8 |
| TEN 20-2411 | 20 W | 18 V to 36 V | 5 V at 4000 mA | 1500 VDC | 2 x 1 inch |
| THN 15-2411 | 15 W | 18 V to 36 V | 5 V at 3000 mA | 1500 VDC | 1 x 1 inch |
| DCP010505BP | 1 W | 4.5 V to 5.5 V | 5 V at 200 mA | 1 kVDC | DIP |
| DCH010505DN7 | 1 W | 4.5 V to 5.5 V | Plus and minus 5 V at 100 mA | 3 kVDC | DIP |
| V24A5C400BL | 400 W | 18 V to 36 V | 5 V at 80 A | 3 kVDC | Maxi brick |
| V24B5C200BL | 200 W | 18 V to 36 V | 5 V at 40 A | 3 kVDC | Mini brick |
Key Features
Barrier specified as a test voltage – each family states the isolation test voltage and the working voltage behind it, so the number quoted to a safety review is the number on the datasheet.
Encapsulated construction – the module is potted, so creepage and clearance are fixed by the package rather than by the board layout under it.
Wide input ranges – 2 to 1 and 4 to 1 input parts hold regulation across a 9 V to 36 V or 18 V to 36 V window, which matters on a 24 V rail that dips during transients.
Single and dual outputs – plus and minus 5 V and plus and minus 12 V versions supply an isolated amplifier or a bipolar reference from one module.
Remote on and off – the 2 W and 3 W SIP parts can be sequenced from a supervisor, so an isolated front end is not powered before the digital side is ready.
Short circuit behaviour stated – indefinite short circuit protection is declared per family, which decides whether a module can sit behind a connector that the user can short.
Applications
These modules are quoted for floating and isolated rails, typically where: An isolated section is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same board, so the modules, the barrier parts and the assembly arrive together.
Isolated measurement front ends – a shunt or a bridge sits at a common mode voltage that the digital ground cannot accept, and the whole analogue section is powered from a 1 W module.
RS-485, CAN and fieldbus ports – the transceiver side of the barrier needs 5 V at a few hundred milliamps and a 3 kVDC barrier against the field wiring.
Gate drive and power stages – an upper device needs a supply referred to its source, and a 2 W or 3 W module with a wide input range covers the variation of the 24 V rail.
Sourcing and Cross-Reference
Isolated modules are specified by four numbers that have to be read together: input range, output voltage and current, isolation test voltage, and footprint. Two modules with the same 1 W rating can differ in whether the output is regulated, whether the barrier is 1 kV or 5.2 kV, and whether the pinout is SIP-4 or SIP-8. We quote the full order code and state the input range on the confirmation, because a 5 V nominal part dropped into a 24 V rail is a return, not a substitution.
On long life instruments the module is often the part that changes first, since the 1 W SIP families are revised more often than the converters around them. The practical route is to keep the footprint and the isolation class and take the current revision of the same family; where the family has gone, we propose an equivalent with the same pinout and state the difference in regulation and ripple so the analogue performance can be judged before the board is re-laid.
Where the boards are assembled in volume, SUPERB Assembly support covers the SMT and through hole build of the isolated section.
Q: Can you confirm the isolation test voltage and the input range for each module on the quote?
A: Yes. Send the complete order code, the input range, the output voltage and current and the isolation test voltage, and the SUPERB Tech sales team will confirm availability and lead time.
Why Buyers Source Isolated Modules Through SUPERB
- Four numbers on every quote: input range, output, isolation and footprint are stated together, so a module is not chosen on its wattage alone.
- Pin compatible alternatives: when a family is revised we propose the same footprint and isolation class first, and state the ripple and regulation difference.
- Module and connector together: the module, its input fuse and the isolation barrier parts around it are quoted as one set, which keeps the safety review package complete.
- Batch data for the safety file: date code, lot and isolation test reference per reel are recorded for the technical construction file.