Optical Slits and Apertures for Monochromator Entrances
Product Specifications
Product Overview
The entrance slit of a monochromator is a compromise that is fixed mechanically and cannot be adjusted once the instrument is built. A wider slit passes more light and a narrower slit passes a narrower band, and the two cannot both be improved at the same time. The band that reaches the detector is the slit width multiplied by the dispersion of the bench, so on a bench that spreads 10 nm across each millimetre, a 100 micrometre slit passes a 1 nm band and a 10 micrometre slit passes a 0.1 nm band at one tenth of the light.
For a compact instrument the slit width is chosen from the detector, not from the grating. A photodiode array with a 25 micrometre pixel pitch already samples the focal plane every 25 micrometres, so a slit narrower than one pixel does not add resolution, it only removes light. That is why a compact spectrograph with a 1024 element array is usually fitted with a 20 to 50 micrometre slit, while a scanning monochromator with a photomultiplier can use a 10 micrometre slit and gain resolution at the cost of signal.
Mechanical quality matters as much as width. A slit cut in 50 micrometre stainless foil has two edges that are close enough together to diffract the light that passes, and any burr or taper shows up as a shoulder on the band profile. The foils on this page are black oxide treated on both sides, which reduces the light that scatters off the face around the opening, and widths of 40 micrometres and below are counterbored so the material around the opening is thinner and the edge is cleaner.
Mounting is the second decision. A half inch mounted slit fits a SM05 lens tube and is the standard for a compact bench, a one inch mounted slit fits a larger tube and is used where the beam is wider, and a bare foil is used inside a custom holder or where the slit is placed against a detector window. The 3 mm length matches a beam that is tall and narrow, and the 10 mm length is used where the beam is spread by a cylindrical lens or where the slit is also the field stop.
An aperture is not only a slit. The same foil family includes round pinholes and half aperture foils for knife edge scans, and the choice between a slit and a pinhole depends on whether the bench images a line or a point. A slit passes a line image and keeps the height of the detector illuminated, while a pinhole defines a point and is used for alignment, for confocal work and for measuring a point spread function.
Key Specifications
| Parameter | Value | Note |
|---|---|---|
| Slit width range | 5 to 500 um | 3 mm length covers 5 to 500 um, 10 mm length covers 20 to 500 um |
| Slit length | 3 mm or 10 mm | 3 mm for a line image, 10 mm where the beam is spread |
| Width tolerance, 5 to 10 um | +/- 1 um | the tightest band in the range |
| Width tolerance, 15 um | +/- 1.5 um | 10 percent of nominal |
| Width tolerance, 20 to 30 um | +/- 2 um | used for the common compact bench widths |
| Width tolerance, 40 to 50 um | +/- 3 um | the band where counterboring starts |
| Width tolerance, 100 to 200 um | +/- 4 um | the workhorse band for array spectrographs |
| Width tolerance, 500 um | +/- 10 um | widest opening, used for throughput at low resolution |
| Foil thickness | 50 um | 300 series stainless steel, black oxide conversion coating on both sides |
| Foil diameter | 9.6 mm, which is 0.38 in | the bare foil drops into a half inch holder |
| Housing diameter | 12.7 mm or 25.4 mm | half inch or one inch, black anodized 6061-T6 aluminium |
| Housing thickness | 2.5 mm, which is 0.10 in | the front face is engraved with the part number and the width |
| Counterbore | included on widths of 40 um and below | thinner material at the edge gives a cleaner band profile |
| Air slit thickness, Edmund precision | 0.01 mm nominal | 100 um wide, 3.0 mm long, stainless steel |
| Air slit outer diameter | 9.5 mm unmounted, 25.0 mm mounted | the mounted version is sealed into a black anodized mount |
| Air slit centring | +/- 125 um from the mount centre | stated on the mounted part, not on the bare foil |
| Air slit width tolerance | +/- 5 um at 100 um | wider than the foil family at the same nominal width |
Included Models and Order Codes
Part numbers follow the housing and the length. The H in a Thorlabs code marks a half inch housing, the K marks a one inch housing where the code ends in K, and the UL marks an unmounted foil with a 10 mm length. The number before the letter is the nominal width in micrometres, so S20HK is a 20 micrometre slit in a half inch mount and S20ULK is the same width as a bare 10 mm foil. The Edmund codes below are catalogue numbers rather than width codes, so the width has to be read from the description.
| Part | Width | Length | Format | Note |
|---|---|---|---|---|
| S5HK | 5 um +/- 1 um | 3 mm | 12.7 mm mounted housing | narrowest stocked slit, counterbored |
| S10HK | 10 um +/- 1 um | 3 mm | 12.7 mm mounted housing | used for high resolution scanning benches |
| S15HK | 15 um +/- 1.5 um | 3 mm | 12.7 mm mounted housing | between the 10 and 20 um steps |
| S20HK | 20 um +/- 2 um | 3 mm | 12.7 mm mounted housing | common with a 25 um pitch array |
| S50HK | 50 um +/- 3 um | 3 mm | 12.7 mm mounted housing | throughput option for a compact bench |
| S100K | 100 um +/- 4 um | 3 mm | 25.4 mm mounted housing | larger housing for a wider beam |
| S200K | 200 um +/- 4 um | 3 mm | 25.4 mm mounted housing | low resolution, high light |
| S500K | 500 um +/- 10 um | 3 mm | 25.4 mm mounted housing | widest opening in the series |
| S20ULK | 20 um +/- 2 um | 10 mm | bare foil, 12.7 mm diameter | for a custom holder or a detector window |
| S50ULK | 50 um +/- 3 um | 10 mm | bare foil, 12.7 mm diameter | 10 mm length gives a taller line image |
| S100ULK | 100 um +/- 4 um | 10 mm | bare foil, 12.7 mm diameter | used ahead of a cylindrical lens |
| 4372 | 100 um +/- 5 um | 3 mm | bare foil, 9.5 mm diameter | Edmund precision air slit, 0.01 mm foil |
| 15399 | 100 um +/- 5 um | 3 mm | 25.0 mm mounted | Edmund air slit, centring +/- 125 um |
Which Length and Housing to Order
The four format groups below cover the same widths in different mechanical packages. The format is decided first, because a bare foil cannot be screwed into a lens tube and a mounted slit cannot be bonded against a detector window without removing the foil from its housing.
| Format | Slit length | Outer diameter | Fixing | Typical position |
|---|---|---|---|---|
| Mounted in a half inch housing | 3 mm | 12.7 mm | SM05 thread, 2.5 mm thick body | entrance slit of a compact spectrograph |
| Mounted in a one inch housing | 3 mm | 25.4 mm | one inch mount, 2.5 mm thick body | bench with a wider beam or a larger grating |
| Bare foil, half inch diameter | 10 mm | 12.7 mm | clamped between two plates | custom holder or the face of a detector |
| Mounted in a one inch housing | 10 mm | 25.4 mm | one inch mount | tall line image, field stop duty |
| Precision air slit, unmounted | 3 mm | 9.5 mm | clamped, 0.01 mm foil | alignment and point spread measurement |
| Precision air slit, mounted | 3 mm | 25.0 mm | sealed into a black anodized mount | bench where the slit must be swapped quickly |
Key Features
Width bands with stated tolerance – 5 and 10 micrometres are held to one micrometre, 20 and 30 to two, 100 and 200 to four, and 500 to ten.
Two slit lengths – 3 mm for a line image on a compact bench and 10 mm where the beam is spread by a lens or the slit doubles as a field stop.
Black oxide on both faces – The coating absorbs the light that scatters off the foil face around the opening, which lowers the stray light floor.
Counterbored narrow slits – Widths of 40 micrometres and below are thinned around the opening so the edge is sharper and the band profile is cleaner.
Housings that fit standard tubes – Half inch and one inch black anodized aluminium bodies drop into the lens tubes already on the bench.
Bare foils for custom holders – The same slit is available unmounted in a 9.6 mm foil, which is the form used against a detector window or inside a machined block.
Engraved identification – The front face carries the part number and the width, so a slit that is swapped during service is not mixed up with another width.
Wide and narrow in one range – 5 micrometres to 500 micrometres from one family means the same holder and the same handling for a high resolution and a high light bench.
Applications
Slits sit in three places in an optical instrument, and each one is chosen for a different reason.
Monochromator entrance – The entrance slit defines the band that reaches the grating, so the width is chosen against the dispersion of the bench and the pixel pitch of the detector.
Exit slit and order sorting – A second slit at the exit passes one band and blocks the rest, which is how a scanning instrument rejects stray light from adjacent orders.
Alignment and knife edge scans – A bare foil with a 10 or 20 micrometre opening is scanned across a focus to measure the spot, which is the cheapest way to check a bench after service.
Detector field stop – A slit bonded against a detector window limits the area that sees light and keeps a stray reflection from reaching the active pixels.
Slits are fitted to the optical benches on SUPERB PCB and SUPERB PCBA analyser builds, where the entrance slit is aligned before the grating is fixed.
Sourcing and Cross-Reference
Slits are low value parts with a high cost of error, because a slit of the wrong width is not visible on the bench and only shows up as a resolution or a signal problem. The order is therefore placed on the width, the length, the format and the tolerance together, and the tolerance is the field that a general catalogue number does not carry. A 100 micrometre slit at plus or minus 4 micrometres and a 100 micrometre air slit at plus or minus 5 micrometres are used in different places even though both are called 100 micrometres.
Where a bench is copied from an existing instrument, the slit is often the part that is hardest to trace, since it is engraved with a width rather than a maker code. The practical route is to measure the old foil under a toolmaker microscope and match the width, the length and the outer diameter, then choose the nearest catalogue band. A foil that measures 98 micrometres is a 100 micrometre part within tolerance, not a custom width.
Delivery is short on the stocked widths and longer on the extremes. The 5 micrometre and 500 micrometre ends of the range are the lines that run out first, so a production instrument that uses one of them keeps a buffer rather than ordering against the line. The mounted and unmounted versions of the same width are also stocked separately, which is why a bare foil is not a substitute for a mounted part when a tube mount is what the bench has.
The slit, the holder and the retaining ring are kitted as one set for SUPERB Assembly, so a service swap does not need three part numbers.
Q: Can you supply a slit in the same width and outer diameter as the one already on our bench?
A: SUPERB Tech asks for the outer diameter and the slit length before quoting, because the same width is stocked in four mechanical formats.
Why Buy Optical Slits Through SUPERB
- Width and tolerance together: The tolerance band is quoted with the width, so a replacement is the same part and not only the same nominal number.
- Format matched to the bench: Half inch, one inch, bare foil and air slit formats are quoted together, which is what a bench with mixed mounts needs.
- Optics and electronics in one place: The slit can be ordered with the grating, the lamp and the detector that share the same optical path.
- Small parts without a minimum: A single foil or a small pack is supplied, which suits a service spares shelf rather than a production line.
- Traceable width for service records: The engraved width and the maker code are recorded on the shipment, so a service report can name the part that was fitted.
- Support on the optical choice: The width is confirmed against the dispersion and the detector pitch before the order, because a narrower slit is not always a better one.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Monochromator Gratings and Optical Bench Parts, Lamp Housings and Shutters, Xenon and Deuterium Lamps, UV and Visible LED Sources, Quartz Flow Cells and Cuvettes, Turbidity and Photometric Detector Modules, Component Lead Time Solutions.