Grounding Studs and Earth Terminals for Chassis Wiring
Product Specifications
Product Overview
A grounding stud is a fastener that exists for one reason: to give a lug a flat, conductive, mechanically sound seat on a chassis. Every part on this page does that job in a different way, and the difference matters at the drawing stage. A self-clinching stud is pressed into a punched or drilled hole in sheet metal and locks itself in place with a knurled shoulder. A self-piercing stud is pressed into a panel without a pre-drilled hole and forms its own seat. A CD weld stud is welded to the panel with a capacitor discharge gun. A rail earth terminal does the same job on a DIN rail inside a cabinet, where the bond is made to the rail rather than to the sheet.
The self-clinching part on this page is the PEM FHS-M6-30. It needs a 6.0 mm hole, sits in sheet of HRB 70 or softer, and puts an 8.2 mm head on the panel face with a 30 mm thread length. The installation figures are the part that gets skipped: on 2.2 mm steel the pull-through is 10.6 kN, the pushout is 2.56 kN and the torque-out is 10.1 Nm. On 2.4 mm aluminium the same stud gives 9.09 kN, 1.66 kN and 7.3 Nm. Those are the numbers a bonding check is written against, and they are the reason the same stud is not simply moved from a steel bracket to an aluminium one without a second look.
The self-piercing part is the PROFIL KSB-H in M6, ordered as KSB0617A20A-H. It needs no hole at all, which is why it is used on painted or coated panels where a drilled hole would need masking and re-sealing. It takes panels from 2.2 mm, works up to roughly 500 MPa panel strength, and joins aluminium as well as steel. The head is 17 mm across, the stud stands 14 mm overall with a 7.6 mm shank below the head and a 3.5 mm collar, and the nut is a 10 mm across flats part in class 8. Because the panel is displaced rather than cut, there is no reverse side marking, and the joint is sealed to IP67 depending on panel thickness and material.
CD weld studs are the third route and the oldest. The JHP range covers 1/4-20, M6 and M8 in mild steel with a copper plate or in stainless, in lengths of 0.590 in, 0.750 in and 16.0 mm. A capacitor discharge weld needs 110 V at the gun and leaves no reverse side mark, because the thermal input is small and short. This is the part to reach for when the panel is already formed and painted, and when a hole would mean stripping the finish around it. The weld is also the joint that is hardest to check after the fact, so the pull test on the first unit is not optional.
The rail earth terminal is the fourth route and it belongs inside the cabinet rather than on the chassis. The Phoenix UT 2,5-PE takes 0.14 to 4 mm2 in screw connection, clips on NS 35/7.5 and NS 35/15 rail, and is 5.2 mm wide, so a bank of them costs very little rail length. It is a green-yellow protective conductor terminal with ATEX approval, and it is the part that ties the cabinet earth bar to the incoming protective conductor. On a rack build the chassis stud and the rail terminal are two ends of the same bond, and both have to be in the drawing.
The practice points are the same on all four routes. Paint has to be removed under the lug or the bond is a capacitor rather than a conductor. A star washer under the lug bites through the last of the coating and is cheap insurance. The torque has to be written on the drawing, because 5 Nm and 10 Nm on an M6 stud are the difference between a bond that passes a millivolt drop test and one that drifts. And dissimilar metals need a plated washer between them, because a bare copper lug on an aluminium panel is a corrosion cell that shows up as a rising resistance two years later.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Stud types on this page | Self-clinching, self-piercing, CD weld | All studs |
| Thread sizes | M6, M8, 1/4-20 | By part |
| Sheet hardness for clinching | HRB 70 / HB 125 or less | FHS-M6-30 |
| Hole size in sheet | 6.0 mm | FHS-M6-30 |
| Minimum sheet thickness | 1.0 mm recommended, 2.2 mm for the self-piercing part | By part |
| Minimum hole centre to edge | 7.9 mm | FHS-M6-30 |
| Pull-through on 2.2 mm steel | 10.6 kN | FHS-M6-30 |
| Pushout on 2.2 mm steel | 2.56 kN | FHS-M6-30 |
| Torque-out on 2.2 mm steel | 10.1 Nm | FHS-M6-30 |
| Panel thickness for self-piercing | From 2.2 mm, up to about 500 MPa | KSB0617A20A-H |
| Weld stud materials | Mild steel copper plated, stainless steel | CD weld studs |
| Weld input | 110 V capacitor discharge | CD weld studs |
| Earth terminal cross section | 0.14 to 4 mm2, rated 2.5 mm2 | UT 2,5-PE |
| Earth terminal mounting | NS 35/7.5 and NS 35/15 rail, 5.2 mm wide | UT 2,5-PE |
| Earth terminal approval | ATEX, UL, CSA, DNV | UT 2,5-PE |
Included Models and Order Codes
The rows below are the studs and terminals we quote most often. Hole size, panel thickness and the mechanical figures are given per part because those are the numbers that decide whether a bond passes, and a dash means the maker does not publish that figure.
| Part Number | Type | Thread | Panel or Rail | Key Dimensions | Notes |
|---|---|---|---|---|---|
| FHS-M6-30 | Self-clinching stud, stainless | M6 | Hole 6.0 mm, sheet HRB 70 | L 30 mm, head 8.2 mm, S max 3 mm | Pull-through 10.6 kN on 2.2 mm steel |
| KSB0617A20A-H | Self-piercing earth stud | M6 | Panel from 2.2 mm | l1 14 mm, l3 7.6 mm, l4 3.5 mm, d3 13.2 mm | Class 8.8, SW 10 nut, sealed joint to IP67 |
| CD weld stud 1/4-20 | Capacitor discharge weld stud | 1/4-20 | Steel or stainless panel | 0.590 in, 0.750 in | Copper plated mild steel option, no reverse mark |
| CD weld stud M6 | Capacitor discharge weld stud | M6 | Steel or stainless panel | 16.0 mm | 110 V weld gun, no reverse mark |
| CD weld stud M8 | Capacitor discharge weld stud | M8 | Steel or stainless panel | 16.0 mm | For heavier fault current bonds |
| UT 2,5-PE | Protective conductor rail terminal | Screw, 0.14 to 4 mm2 | NS 35/7.5 and NS 35/15 | Width 5.2 mm, green-yellow | ATEX approved, ties cabinet earth bar |
Key Features
Hole size and edge distance stated – The 6.0 mm hole and 7.9 mm minimum centre to edge are given for the M6 clinching stud, which is what decides whether a panel can take the part at all.
Mechanical figures per material – 10.6 kN pull-through in 2.2 mm steel and 9.09 kN in 2.4 mm aluminium are listed separately, because a bonding check written for steel does not pass on aluminium.
Self-piercing option – The M6 self-piercing stud needs no hole and leaves no reverse side mark, which saves masking and re-sealing on a coated panel.
Weld studs in three threads – 1/4-20, M6 and M8 CD weld studs cover the common chassis bond sizes without changing the tooling on the line.
Rail terminal in a 5.2 mm width – The protective conductor terminal costs 5.2 mm of rail, so a bank of earth points fits a shallow cabinet.
Ratings from the maker data sheet – Every figure on this page is taken from the part data, so the drawing, the inspection sheet and the quote all use the same number.
Applications
These parts are used where a chassis, a rack or a cabinet has to be bonded to protective earth and the bond has to survive vibration and time.
Rack and cabinet chassis – A 30 mm M6 self-clinching stud through a 2.2 mm steel chassis gives a 10.1 Nm torque-out seat for the earth lug, with the star washer and torque called out on the drawing.
Coated and painted panels – A self-piercing M6 stud on a 2.5 mm painted panel leaves the finish intact on both faces and still seals to IP67 at the joint.
Cabinet earth bars – Green-yellow UT 2,5-PE terminals on 35 mm rail tie the earth bar to the incoming protective conductor in 5.2 mm of rail width per pole.
A bonding point is set before the harness goes in, so the stud pattern is checked against the SUPERB PCB ground plane and the panel cut on the first unit. On the SUPERB PCBA route the rail earth terminal is fitted after the board is in place, because a terminal clipped on before the board is dropped in is a terminal that gets knocked off its rail.
Sourcing and Cross-Reference
A stud is bought by panel, not by thread. The same M6 thread exists as a clinching part, a self-piercing part and a weld part, and the three need different panels, different tools and different inspection. When a stud is replaced on a chassis that is already in production, the thread and the length are the easy part. The panel thickness, the hole and the minimum edge distance are what decide whether the replacement can be fitted at all.
The second point is the bonding path. A stud carries the fault current from the lug into the panel, so the joint resistance is the figure that matters, not the tensile strength. That is why the panel is cleaned to bare metal under the lug, why a plated washer goes between dissimilar metals, and why the torque is written on the drawing. A bond that reads 2 milliohms on the first unit and 40 milliohms a year later was not a bad stud, it was a joint that was never sealed.
The third point is inspection. A clinched stud can be checked by pull and torque on a sample, a weld stud by a bend and a pull on the first unit, and a rail terminal by a tug on the conductor. We quote the stud together with the tooling it needs, because a self-piercing part that arrives without the press tool is a part that sits in stores. Where the panel is already painted and a weld is not possible, the self-piercing route is the one that keeps the finish.
SUPERB Assembly torque-checks every bonding point on the first unit and writes the value down, because a stud that shears at 8 Nm and a stud that holds at 10 Nm look identical on a drawing.
Q: Can you supply an M6 grounding stud for a 2.5 mm painted panel with no reverse side mark, and give the hole size, edge distance and torque for the drawing?
A: Send the panel material and thickness, the fault current the bond has to carry and the space behind the panel. The SUPERB Tech desk quotes the stud with its hole size and its minimum centre distance to the edge, because a 6 mm hole 4 mm from a bend is a hole that tears the panel.
Why Buy Grounding Studs and Earth Terminals Through SUPERB
- Panel thickness checked first: Every stud is quoted against the panel it goes into, which is where a 1.0 mm clinching part gets ordered for a 3 mm bracket.
- Mechanical figures on the quote: Pull-through, pushout and torque-out are stated per part and per panel material, so the bonding check is written against real numbers.
- Three fixing routes: Clinching, self-piercing and weld studs are on one page, so a painted panel and a bare chassis are not forced onto the same part.
- Rail terminals in the same order: The protective conductor terminal is quoted with the stud, because a chassis bond and a cabinet bond usually ship together.
- Checked at assembly: The first unit is torque-checked and recorded, because a bond that is only drawn is a bond that is only assumed.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Turret Terminals and Solder Lugs for Panel Wiring, Standoffs Spacers and Mounting Hardware for Board Stacks, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Cable Clamps and Harness Ties for Internal Wiring, TVS and ESD Protection Diodes for Telecom and Industrial Interfaces, How to Verify a Drop in Replacement.