Contact Us
  • Home
  • COMPONENTS
  • Turret Terminals and Solder Lugs for Panel Wiring

Turret Terminals and Solder Lugs for Panel Wiring

A turret terminal is a post a wire is wrapped around and soldered to, and the dash number on the part is the board thickness it is swaged into. The brass posts here are bright tin plated to MIL-T-10727 Type 1, in single, double and triple turret styles, with heights above the board from 2.36 mm to 7.65 mm. Mounting holes run from 1.70 mm to 2.39 mm, and the flange is 3.18 mm across on the swage mount bodies. The solder lugs on the same page are lockwasher lugs for a #4 or a #8 stud, in 0.018 inch brass with a matte tin finish.
quote now

Product Specifications

Product Overview

A turret terminal gives a wire a place to land that is not the board itself. The post stands above the surface, the wire is wrapped once and soldered, and the joint can be inspected and reworked without lifting a pad. It is the part used on tag boards, filter assemblies, test jigs, transducer headers and the panel wiring of older instruments, where a wire arrives from a terminal block and has to be made off inside the case.

The Keystone posts are swage mount parts. The body is pressed into a hole in the board and the flange on the underside is swaged over, so the terminal is held by the board rather than by solder alone. The material is brass to ASTM-B16 with a bright electro tin finish to MIL-T-10727 Type 1, which is the finish that keeps the part solderable after a year on a shelf. The dash number carries the board thickness: -1 for 0.81 mm, -2 for 1.57 mm, -3 for 2.36 mm and -4 for 3.2 mm.

The styles matter more than the size. A single end turret has one post above the board, a double end part has a post that passes through the board and is used as a feed through, and the split or fork style has a slot in the post so a wire is laid in from the side and soldered without being threaded. A tubular style is hollow, which is used where a component lead comes up through the post. The table below names the style per part, because a fork and a solid post are not interchangeable on a harness that is made off in the field.

The height above the board is the figure a mechanical engineer sets, and it is the figure that is hardest to change later. A 2.36 mm post is right where the wire is dressed against the board, and a 7.65 mm post is right where a test probe has to reach the joint or where two wires land on the same point. The 1502 body is 5.56 mm above the board, the 1520 is 4.75 mm and the 1598 is 7.65 mm, all with the same 3.18 mm flange and the same staking geometry.

The mounting hole has to match the staking diameter, not the thread of the wire. A 1502 body takes a 2.39 mm hole, a 1520 takes 2.08 mm and a 1508 takes 1.70 mm. A hole that is 0.1 mm oversize lets the flange swage into the gap instead of over the pad, and the terminal is loose in the board before the first wire is soldered. That is why the hole is called out with the part rather than taken from a general rule.

The solder lugs are the other half of the page and they solve a different problem. A lockwasher lug is bolted to a chassis or a stud, with the internal teeth biting through the paint or the anodising to make the bond. The 7316 takes a #8 stud and is angled, with an overall length of 18.24 mm and a 2.36 mm hole, and the 7314 takes a #4 or M3 stud in 0.45 mm brass with a matte tin finish. Both are used for a chassis ground or a high current return that cannot be carried on a track.

Key Specifications

ParameterValueApplies to
MaterialBrass to ASTM-B16Turret terminals
PlatingBright electro tin to MIL-T-10727 Type 1Turret terminals
Board thickness options0.81 mm, 1.57 mm, 2.36 mm, 3.2 mmDash numbers 1 to 4
Mounting hole1.70 mm, 2.08 mm, 2.39 mm1508, 1520, 1502 and 1598 bodies
Flange diameter3.18 mmSwage mount bodies
Turret head diameter2.36 mm1502 body
Height above board2.36 mm to 7.65 mmBy body
StakingSwage, flareTurret terminals
StylesSingle, double and triple turret, split, tubular, feed throughKeystone range
Solder lug material0.45 mm brass, matte tin7314 and 7316
Stud size#4 and M3, #87314, 7316
Lug styleLockwasher, internal tooth7314 and 7316

Included Models and Order Codes

The rows below are the terminals we quote most often. The dash number, the height above the board and the mounting hole are given per part because the same post is made in four board thicknesses, and a dash means the maker does not publish that figure.

Part NumberStyleBoard ThicknessHeight Above BoardMounting HoleOverall LengthNotes
1508-2Single turret1.57 mm2.36 mm1.70 mm4.50 mmLow post, 2.13 mm below flange
1502-2Double turret1.57 mm5.56 mm2.39 mm8.33 mm3.18 mm flange, 2.36 mm head
1502-3Double turret2.36 mm5.56 mm2.39 mm9.14 mmSame post for a thicker board
1520-2Single turret1.57 mm4.75 mm2.08 mm7.52 mmMid height single end post
1598-2Triple turret1.57 mm7.65 mm2.39 mm10.03 mmTall post for two wires or a probe
7316Lockwasher lug, angled--2.36 mm for a #8 stud18.24 mmInternal tooth, brass, tin
7314Lockwasher lug--For a #4 or M3 stud-0.45 mm brass, matte tin, 3.1 mm ring

Key Features

Dash number carries the board – The -1, -2, -3 and -4 suffixes are 0.81 mm, 1.57 mm, 2.36 mm and 3.2 mm boards, so the same post is ordered for the board that is actually being built.

Height stated per body – 2.36 mm to 7.65 mm above the board is given per part, which is the figure a wire dress or a probe point is set from.

Hole matched to the staking – 1.70 mm, 2.08 mm and 2.39 mm holes are listed with the bodies that need them, so a 0.1 mm oversize hole does not turn a swage into a loose fit.

Brass under tin – ASTM-B16 brass with a bright tin to MIL-T-10727 Type 1 stays solderable on a shelf and takes a wrapped joint without a flux soak.

Styles named – Single, double, triple, split and tubular are stated, because a fork post and a solid post are used differently on a field made harness.

Lockwasher lugs for chassis – The 7314 and 7316 bite through paint and anodising on a stud, which is what a chassis ground needs and a plain ring lug does not give.

Applications

These terminals are used where a wire has to land on a post, be inspected, and be reworked without lifting a pad.

Filter and tag assemblies – A row of 1502 posts carries the wires of a filter can, with the 5.56 mm height giving room for a wrapped joint and a sleeve.

Test jigs and burn in racks – A 1598 triple turret gives 7.65 mm of height so a probe can reach the joint while a wire is still landed on the post.

Chassis grounds and returns – A 7316 lockwasher lug on a #8 stud bonds a panel to the chassis through the paint, with the internal teeth making the contact.

A turret stands above the SUPERB PCB by a fixed height, so the wire is routed at that height rather than at the board surface. On the SUPERB PCBA route the terminal is swaged after the through hole solder step, because the flange has to sit on a clean pad.

Sourcing and Cross-Reference

A turret terminal is bought by height and approved by the board thickness. When a post is replaced on an existing board, the dash number and the mounting hole are the two figures to check, because a -2 body in a board that was routed for a -3 sits low and the swage has nothing to flare over. We ask for the board thickness rather than the part number where the part number is not marked on the board.

The second point is the style. A solid post and a split post look alike in a photograph, and they are used differently: a split post takes a wire laid in from the side, which is what a field engineer does with a soldering iron and no wire stripper access, and a solid post needs the wire wrapped. Where a product is serviced in the field, the split style is usually the right answer, and it is a different order code from the solid one.

The third point is the finish. A bright tin over brass is the standard for solderability, and a bare brass part will take a joint on the bench and fail a shelf life test a year later. Where the terminal is also a contact surface, a gold finish is available on the same body, and where the part is bolted to a chassis rather than soldered, a lockwasher lug with a matte tin is the part rather than a turret at all.

SUPERB Assembly swages the flange with a press rather than a punch, because a terminal that is set with a hammer splits the brass and the post goes slack in the hole.

Q: Can you supply a double turret terminal for a 1.57 mm board that stands 5.5 mm above the surface, and confirm the mounting hole before we route the panel?

A: Send the board thickness, the wire size and the height the wire has to sit at. The SUPERB Tech desk quotes the terminal with the dash number that matches the board, because the same post is made in four board thicknesses.

Why Buy Turret Terminals Through SUPERB

  1. Board thickness in the part number: The dash number is checked against the board rather than assumed, which is where a swage fit fails.
  2. Height chosen before routing: The post height is quoted up front, so a wire dress or a probe point is not changed after the panel is made.
  3. Hole matched to the staking: The mounting hole is given with the body, so the drill is right the first time.
  4. Styles kept apart: Solid, split, feed through and tubular posts are named per part, because they are used differently in the field.
  5. Swaged at assembly: The flange is set with a press on the line, because a terminal set by hand splits at the flange and goes slack.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Test Points and Spring Contacts for Board Probing, Standoffs Spacers and Mounting Hardware for Board Stacks, Banana Jacks and Binding Posts for Test and Bench Panels, How to Verify a Drop in Replacement.