A field wiring connector is chosen on pitch, current and wire range, because those three decide the copper area and the space left on the board edge. Fixed blocks on this page run from 2.54 mm to 5.0 mm pitch at 10 to 18 A, while the two piece pluggable parts reach 32 A at 7.62 mm. UL and IEC ratings differ on the same part, so both are listed wherever the maker publishes them. Each row lists pitch, current, voltage, wire range and terminal style.
quote now

Product Specifications

Product Overview

A board that leaves the enclosure needs a wire connection that a technician can make with a screwdriver and check by pulling. Two families do that job. A fixed terminal block is soldered to the board and the wire is clamped into it directly, which is the cheapest route and the one used on power entry, relay outputs and sensor headers. A pluggable connector splits the joint in two: a header stays soldered to the board and a plug carries the wires, so a harness can be built and tested away from the board and then mated in one movement.

Pitch is the first limit on current. The 2.54 mm parts in this list carry 10 A and accept wires from 30 to 16 AWG, which covers signal and low power runs on a dense board. The 3.81 mm family carries 8 A with a 1.5 mm2 nominal cross section, the 5.0 and 5.08 mm families carry 12 to 15 A with 2.5 mm2, and the 7.62 mm header reaches 32 A at 6 mm2. Read the pitch together with the wire range, not on its own: a 5.08 mm block that accepts 2.5 mm2 cannot be fed with the 4 mm2 cable that a 32 A load needs.

The two halves of a pluggable pair must come from the same series, and this is where most wrong orders start. A 5.08 mm plug from one series and a 5.08 mm header from another look compatible, both have the same pitch and the same pin count, and they do not mate. The parts on this page are quoted as pairs, with the series named on both rows, so a replacement plug is ordered against the header that is already on the board rather than against the pitch alone.

Ratings on the same block can differ by a wide margin between the two standards. The Degson DG126-5.0 fixed block is rated 300 V and 10 A under UL and 250 V and 18 A under IEC. The Phoenix MSTB 2,5 header is 12 A at 320 V for overvoltage category III/2, while its CSA group B figure is 15 A at 300 V. When a customer quotes a current, the standard behind it has to be named, because a 10 A UL figure is not the same limit as an 18 A IEC figure on the same body.

The last decision is mechanical. Wire strip length is 6 mm on the DG127 plug and 7 mm on the DG126 block, and a strip that is too long leaves bare copper outside the clamp while a strip that is too short sits in the insulation. Screw torque is 0.4 N.m on the Degson parts; above that the thread in the PA66 body yields and the clamp no longer holds. A wire guard or tension sleeve keeps the strands under the screw instead of cutting them, and a push-in spring version removes the screwdriver from the wire side of the joint completely.

Two failures repeat on field wiring. Solder paste that wicks into the thread of a block during reflow seizes the screw, so the block is placed after reflow or the thread is protected. And a block soldered flush to a tall component cannot be reached with a screwdriver at the angle the terminal needs, which is only visible when the harness is fitted for the first time.

Key Specifications

ParameterValueApplies to
Pitch2.54 mm, 3.81 mm, 5.0 mm, 5.08 mm, 7.62 mmPer part number
Nominal current8 A, 10 A, 12 A, 15 A, 32 APer part number
Rated voltage150 VAC to 630 V, per UL and IECPer part number
Wire range0.05 to 6 mm2, 30 to 10 AWGPer part number
Connection styleScrew with tension sleeve, screw with wire guard, push-in springPer part number
Screw torque0.4 N.m on the Degson blocksDG126, DG127
Strip length6 mm on the plug, 7 mm on the fixed blockDG127, DG126
Contact resistance1.4 mOhm on the MSTB header, 20 mOhm on the WR-TBL headerMSTB 2,5, 691313510002
Contact platingTin over nickelWR-TBL, MSTB
Housing materialPA66, UL94 V-0WR-TBL, MSTB, DG series
Positions2 on the parts listed, families to 12 or 24 positionsPer series
Solder pin3.23 mm on the MSTB header, 1.4 mm holeMSTB 2,5/ 2-G-5,08
Operating temperature-40 to 105 C, -40 to 110 CWR-TBL, 282834-2
ApprovalscULus, VDE, CSA where publishedPer part number

Included Models and Order Codes

The rows below are the two position parts we quote most often for board edge wiring, in fixed and pluggable form. UL and IEC figures are given where the maker publishes both, because they are not interchangeable. A dash means the maker does not publish that value for the part.

Part NumberTypePitchCurrentVoltageWire RangeNotes
MSTB 2,5/ 2-G-5,08Header, through hole5.08 mm12 A320 V (III/2)2.5 mm2 nominalSolder pin 3.23 mm, 1.4 mOhm contact, CSA 15 A group B
MSTB 2,5/ 2-ST-5,08Plug, screw5.08 mm12 A320 V (III/2)0.2 to 2.5 mm2Tension sleeve, L slotted screw, mates with MSTB 2,5 header
MC 1,5/ 2-G-3,81Header, through hole3.81 mm8 A160 V (III/2)1.5 mm2 nominalCompact header for signal and low power wiring
MC 1,5/ 2-ST-3,81Plug, screw3.81 mm8 A160 V (III/2)1.5 mm2 nominalTension sleeve, mates with MC 1,5 header
FK-MCP 1,5/ 2-ST-3,81Plug, push-in spring3.81 mm8 A160 V (III/2)1.5 mm2 nominalSpring clamp, 1.4 mOhm contact, no screw on the wire side
PC 5/ 2-G-7,62Header, through hole7.62 mm32 A630 V6 mm2 nominal0.8 mOhm contact, high current board edge
691313510002Header, right angle5.08 mm15 A at 25 C300 V UL, 320 V VDEHeader, no wire entry20 mOhm contact, PA66 body, mates with WR-TBL 313 plug
DG126-5.0-02PFixed block, screw5.0 mm10 A UL, 18 A IEC300 V UL, 250 V IEC0.5 to 2.5 mm2, 26 to 14 AWG0.4 N.m torque, 7 mm strip, M2.6 screw, wire guard
DG127-5.0-02PPlug, screw5.0 mm12 A UL, 15 A IEC300 V UL, 250 V IEC0.2 to 1.5 mm2, 26 to 14 AWG0.4 N.m torque, 6 mm strip, M2.5 screw, PA66 body
282834-2Fixed block, screw, side entry2.54 mm10 A150 VAC0.05 to 1.3 mm2, 30 to 16 AWGWire guard fitted, -40 to 110 C, stackable body

Key Features

Pitch matched to load – The page runs from 2.54 mm at 10 A to 7.62 mm at 32 A, so the block is picked by the cable it has to accept rather than by board space alone.

UL and IEC side by side – Where the maker publishes both, both are listed, because a 10 A UL limit and an 18 A IEC limit sit on the same DG126 body.

Pairs quoted together – Header and plug are listed with the series name on both rows, so a replacement plug is matched to the header already on the board.

Torque and strip length stated – 0.4 N.m and 6 or 7 mm are the two figures that decide whether a field joint holds, and both are given per part number.

Wire guard and spring options – Screw blocks with a guard and push-in spring plugs are both listed, for harness shops that crimp ferrules and for those that do not.

Two piece serviceability – A pluggable pair lets a harness be built and tested off the board, then mated in one movement during final assembly.

Applications

These parts cover board edge wiring on power entry, control panels, instrumentation and outdoor enclosures.

Power entry and relay outputs – A 5.08 mm pair at 12 A carries mains or 24 V load wiring from a board to a terminal rail, and the plug can be removed for a board swap without touching the screws.

Sensor and actuator harnesses – The 3.81 mm family at 8 A suits runs to limit switches, solenoids and thermocouples where the wire is 0.5 to 1.5 mm2 and the block has to fit a narrow edge.

Outdoor and field service units – A fixed block with a wire guard holds stranded wire under the clamp on a unit that is wired on site, and the 7.62 mm version takes the 6 mm2 cable used on a 32 A feed.

Terminal blocks sit on the edge of the SUPERB PCB and on the SUPERB PCBA builds we supply, so the pitch and the wire entry direction are checked against the enclosure before the board is released.

Sourcing and Cross-Reference

Terminal blocks are ordered against three numbers: pitch, positions and wire range. A customer who sends only a photo of the block usually has the pitch right and the series wrong, so we ask for the mating half or the board footprint before quoting. The same 5.08 mm pitch appears in several series that do not mate with each other, and the price difference between them is small enough that a wrong choice is only found at assembly.

When a block is discontinued, the header on the board is the constraint. A replacement plug from the same series drops in, while a plug from another series needs the header changed as well, which means a rework on every board in the build. We name the series and the mating half on the quote so the impact is visible before the order is placed.

Blocks and ferrules are quoted together where the customer wants it. A 2.5 mm2 block with the matching ferrule and the right strip length removes the two things that most often fail on a field joint, and it is the combination we check first on a panel build.

SUPERB Assembly torques every screw to the maker figure and pulls each wire after the first article, which catches a block that was soldered with paste in the thread.

Q: Can you supply a plug that mates with the header already on our board, without changing the footprint?

A: Current, pitch and wire range decide it; the SUPERB Tech desk quotes the header and the plug as a matched pair so the two halves cannot arrive from different series.

Why Buy Terminal Blocks Through SUPERB

  1. Mating half checked: The header or plug already on the board is identified before a quote, so the pair mates on the first build.
  2. Both standards quoted: UL and IEC figures are given where published, so a current limit is not compared across standards by mistake.
  3. Wire range confirmed: The conductor size and the ferrule are matched to the block, not assumed from the pitch.
  4. Legacy series kept: Older series stay available for boards already in service, so a replacement does not force a footprint change.
  5. Assembly in the same house: Blocks are placed and torqued in the same build as the board, so a seized screw is found before the unit ships.