Cable Clamps and Harness Ties for Internal Wiring
Product Specifications
Product Overview
An internal harness has to be held at a spacing that keeps it off the hot parts, away from the moving parts and out of the way of the service access. The clamp is the part that does the holding, and the tie is the part that gathers the wires. They are bought together because a tie with nothing to tie to is a bundle that moves, and a clamp with no tie is a fixing point on a panel. On most builds the two families are quoted in one line item, and the figures that matter are the bundle diameter, the fixing hole and the tensile rating.
The nylon P clamp is the standard part. The Essentra NM series is a fixed loop in nylon 6/6, with a 4.8 mm loop on NM-3-R3 and a 6.4 mm loop on NM-4-R4, a 12.8 mm body width and a hole for a number 10 or M5 screw on both. The MS25281 part numbers on those two rows are the military drawing the mould matches, which is why a buyer who asks for MS25281-R3 gets a clamp that fits the same hole. The 22CC37B0187E is the smaller P clamp in the same material, with a 3.6 mm hole for a number 6 or M3.5 screw and a 9.5 mm body, used where the harness runs along a narrow land.
The steel clamp with an elastomer cushion is the answer where the bundle is hot, where it chafes, or where it has to be held hard. The SPN range is cold rolled steel with a zinc electroplate and a rubber cushion bonded inside the loop, so the cable is isolated from the metal and the clamp damps vibration. The loop runs from 4.8 mm on SPN-3 to 12.7 mm on SPN-8 and SPNW-8, and the wide body version takes a 7.9 mm hole instead of 6.6 mm. On a build that sees vibration the cushioned clamp outlasts a plain nylon loop by a wide margin, because the cushion is what stops the wire insulation wearing through on the loop edge.
The wire harness clip is the wide part. WHC-1000-01 holds a 25.4 mm bundle in a body 38.9 mm long and 12.7 mm wide, with a 5.2 mm hole for a number 10 or M5 screw, in nylon 6/6 to UL94 V-2 and rated from minus 40 to plus 85 C. It is used where a bundle of several wires leaves the board and turns towards the front panel, because a P clamp that size would need a longer land than the panel has. The PVC U clamp V-1002 is the lower cost answer on a 9.5 mm bundle, in black PVC to UL94 V-0, and it is the part used where the cable insulation is soft and a nylon edge would cut into it.
The ties are PA66, and the figures that matter are length, width, bundle diameter and minimum tensile strength. T18R is 100 mm by 2.5 mm for a 22 mm bundle at 80 N, T30R is 150 mm by 3.5 mm for a 35 mm bundle at 135 N, T50R is 200 mm by 4.6 mm for a 50 mm bundle at 225 N, T80R is 210 mm by 4.7 mm for a 55 mm bundle at 355 N and T120R is 387 mm by 7.6 mm for a 100 mm bundle at 535 N. The same T50R body is available in UV stabilised PA66W at 202 mm, which is the part used on anything that sees daylight through a window or a vent.
Two figures decide whether a tie and a clamp work together. The first is the tie width against the clamp or mount opening: a 7.6 mm T120R will not pass through a mount made for a 5 mm tie, and the mount is then the weak point in the run. The second is the temperature. Standard PA66 is rated from minus 40 to plus 85 C, and a tie sitting next to a regulator that runs at 100 C will relax and lose tension over a few hundred hours, which shows up later as a bundle resting on a heat sink. The UV stabilised and heat stabilised materials are the answer, and they are separate part numbers rather than an option on the same one.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Clamp materials | Nylon 6/6, zinc plated steel with elastomer cushion, PVC | Clamps on this page |
| Flammability | UL94 V-2, UL94 V-0 | By part |
| Clamp bundle range | 4.8 mm to 25.4 mm | Clamps on this page |
| Clamp fixing | Number 10 or M5, number 6 or M3.5, M4 tie mount | By part |
| Clamp hole size | 3.6 mm, 4.3 mm, 5.2 mm, 6.6 mm, 7.9 mm | By part |
| Clamp temperature | Minus 40 to plus 85 C | Nylon parts |
| Tie material | PA66 natural, PA66W UV stabilised black | Ties on this page |
| Tie length | 100 mm to 387 mm | Ties on this page |
| Tie width | 2.5 mm to 7.6 mm | Ties on this page |
| Minimum tensile strength | 80 N to 535 N | Ties on this page |
| Tie bundle diameter | 22 mm to 100 mm | Ties on this page |
| Tie flammability | UL94 V-2 | Ties on this page |
| Tie operating temperature | Minus 40 to plus 85 C | PA66 and PA66W ties |
| Tie closure | Plastic pawl, inside serrated, not releasable | Ties on this page |
Included Models and Order Codes
The rows below are the clamps and mounts we quote most often. Bundle diameter, fixing hole and body size are given per part, because a clamp is chosen by the bundle and the screw already on the drawing, and a dash means the maker does not publish that figure.
| Part Number | Type | Bundle Diameter | Fixing | Material | Notes |
|---|---|---|---|---|---|
| NM-3-R3 | P clamp, fixed loop | 4.8 mm | Number 10 or M5 screw | Nylon 6/6 | MS25281-R3, 12.8 mm body |
| NM-4-R4 | P clamp, fixed loop | 6.4 mm | Number 10 or M5 screw | Nylon 6/6 | MS25281-R4, 12.8 mm body |
| 22CC37B0187E | P clamp, screw mount | - | Number 6 or M3.5, 3.6 mm hole | Nylon 6/6 natural | 9.5 mm body, UL94 V-2 |
| SPN-3 | Steel clamp with cushion | 4.8 mm | 6.6 mm hole | Zinc steel, elastomer | 12.7 mm body, 6.7 mm high |
| SPN-4 | Steel clamp with cushion | 6.4 mm | 6.6 mm hole | Zinc steel, elastomer | 12.7 mm body, 6.7 mm high |
| SPN-6 | Steel clamp with cushion | 9.5 mm | 6.6 mm hole | Zinc steel, elastomer | 12.7 mm body, 6.7 mm high |
| SPN-8 | Steel clamp with cushion | 12.7 mm | 6.6 mm hole | Zinc steel, elastomer | 12.7 mm body, 6.7 mm high |
| SPNW-8 | Steel clamp, wide body | 12.7 mm | 7.9 mm hole | Zinc steel, elastomer | 15.9 mm body, 10.3 mm high |
| WHC-1000-01 | Wire harness clip | 25.4 mm | Number 10 or M5, 5.2 mm hole | Nylon 6/6 natural | 38.9 x 12.7 mm, UL94 V-2 |
| V-1002 | U clamp, screw mount | 9.5 mm | Screw mount | PVC black | UL94 V-0, 0.500 inch loop |
| CTAM1 | Cable tie mount | Tie width 5.0 mm | Number 8 or M4, 4.3 mm hole | Nylon black | 151-31101, 100 per pack |
Cable Ties and Bundle Range
Ties are quoted by bundle diameter and tensile rating rather than by length, because a long tie on a thin bundle only leaves a tail to cut. The table gives the published figures per type.
| Type | Material | Length | Width | Max Bundle | Min Tensile | Notes |
|---|---|---|---|---|---|---|
| T18R | PA66 natural | 100 mm | 2.5 mm | 22 mm | 80 N | Smallest tie on this page |
| T30R | PA66 natural | 150 mm | 3.5 mm | 35 mm | 135 N | General harness bundling |
| T50R | PA66 natural | 200 mm | 4.6 mm | 50 mm | 225 N | UL94 V-2, head 7.6 x 5.9 mm |
| T50R PA66W | PA66W UV black | 202 mm | 4.6 mm | 50 mm | 225 N | 112-05060, UV stabilised |
| T80R | PA66 natural | 210 mm | 4.7 mm | 55 mm | 355 N | Heavier bundle |
| T120R | PA66 natural | 387 mm | 7.6 mm | 100 mm | 535 N | Needs a mount for a 7.6 mm tie |
Key Features
Bundle diameter per part – 4.8 mm to 25.4 mm loops are listed with the part, so a clamp is not ordered by eye and then found to be too small for the bundle.
Hole size stated – 3.6 mm to 7.9 mm holes are given, because the panel is punched once and a clamp with the wrong hole is a rework order.
Cushioned steel clamp – The elastomer cushion isolates the cable from the metal and damps vibration, which is what keeps insulation from wearing on the loop edge.
Military drawing part numbers – NM-3-R3 and NM-4-R4 carry the MS25281 drawing numbers, so a buyer asking for the drawing number gets a part that fits the same hole.
Tensile rating from 80 N to 535 N – The tie is chosen by the pull on the cable, not by the length, and the rating is stated per type.
UV stabilised black tie – A separate PA66W part is listed for anything that sees daylight, because standard PA66 goes brittle outdoors.
Applications
These parts are used wherever a harness has to be held at a spacing inside a case, a panel or a rack card.
Instrument and control panels – A 4.8 mm cushioned steel clamp holds a twisted pair against the panel, with the 6.6 mm hole taking the M5 screw already on the drawing.
Telecom and network shelves – A 25.4 mm harness clip turns a multi wire bundle towards the front panel, with the 5.2 mm hole taking a number 10 screw.
Vehicle and mobile racks – A UV stabilised T50R gathers a 50 mm bundle at 225 N, with the black material holding tension where the cable sees daylight and heat.
Every clamp is a fixing point in the panel, so the hole pattern is settled while the SUPERB PCB layout is still open and before the chassis is punched. On the SUPERB PCBA route the harness is clamped after the board is washed, because a clamp that holds solvent against the mask leaves a ring that no amount of rinsing removes.
Sourcing and Cross-Reference
A clamp is bought by bundle and approved by hole. When a clamp is replaced, the bundle diameter on the drawing is the first figure, and the screw already called out is the second, because a clamp with a 6.6 mm hole on an M4 screw is a loose part whatever its loop size. We ask for the bundle with the tolerance, the panel thickness and the screw, and the clamp is chosen from those figures.
The second point is the material. A nylon loop is the economical answer on a bundle that is cool and static, and a cushioned steel clamp is the answer where the bundle is hot, where it vibrates, or where the loop edge would cut into soft insulation. On a build that has to meet a flame requirement, the nylon parts to UL94 V-2 and the PVC part to UL94 V-0 are separate rows rather than the same part bought under two descriptions.
The third point is the tie and the mount together. A tie mount is only as strong as the surface it sits on, and an adhesive mount on a powder coated panel or a dusty board will come away in service. Where the panel can be punched, the screw mount CTAM1 is the part to use. Where it cannot, the adhesive mount is a stop gap and the tie should not be asked to carry the mass of the bundle. We quote the tie and the mount as a pair, with the tie width matched to the mount opening.
SUPERB Assembly lays the harness on the bench, clamps it at the spacing written on the drawing, then fits it to the case, because a harness clamped after it is pulled into place ends up with the tie heads against the connector shell.
Q: Can you supply a 6.4 mm nylon clamp for an M5 screw with a 225 N tie and a screw mount, and confirm the hole size before the panel is punched?
A: Send the bundle diameter, the panel thickness and the screw already called out on the drawing. The SUPERB Tech desk quotes the clamp with its hole size and the tie with its tensile rating, because a 4.8 mm clamp on a 9 mm bundle will not close and a 225 N tie is not the right part for a cable that sees pull.
Why Buy Clamps and Ties Through SUPERB
- Bundle and hole checked first: The clamp is quoted against the bundle and the screw already on the drawing, so a 4.8 mm loop is not ordered for a 9 mm bundle.
- Material matched to the duty: Nylon, cushioned steel and PVC parts are on the same range, so a hot or vibrating run is not held with the economical loop.
- Tie and mount as a pair: The tie width is matched to the mount opening, because a 7.6 mm tie in a 5 mm mount is the weak point in the run.
- Flame class stated: UL94 V-2 and V-0 parts are listed separately, so a requirement is met on the page rather than at the incoming inspection.
- Harness laid before it is pulled: The harness is clamped on the bench and then fitted, which is what keeps the tie heads off the connector shells.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Wire to Board Crimp Housings and Headers for Harness Builds, Cable Glands and Strain Relief Bushings for Enclosure Entries, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Standoffs Spacers and Mounting Hardware for Board Stacks, BOM Shortage Recovery, How to Verify a Drop in Replacement.