Cable Entry Plates and Brush Grommets for Cabinet Bases
Product Specifications
Product Overview
A cable with a moulded connector on the end cannot pass a cable gland. The gland is a ring that seals on the jacket, and the plug is wider than the ring, so the harness either gets cut and re-terminated inside the cabinet or the cabinet gets a slot that nobody wants to seal afterwards.
A cable entry plate solves that by being split. The frame is two halves that close around the cables, and each cable sits in a slit grommet that is pushed into the frame after the plug has passed through. The cut-out in the cabinet base is a rectangle, not a round hole, and the standard rectangles are the footprints of 10, 16 and 24 pin industrial connectors.
Two families cover most cabinets. The KEL frame is a grommet system with a flat gasket, rated IP54 and UL Type 12, and it is the one to use where water or dust has to stay out. The KEL-BES brush plate uses the same cut-outs but seals with polyamide brushes, which stop dust, hair and larger particles while letting air move, and it is the one to use on a ventilated cabinet or a raised floor.
The choice inside each family is arithmetic. Count the cables, note the largest connector that has to pass, then pick the frame whose cut-out is at least the connector footprint. A 24 pin connector needs the 112 x 36 mm cut-out; a 16 pin needs 86 x 36 mm; a 10 pin needs 65 x 36 mm. Where the base is shallow, the 17 mm frame depth of the KEL is the number that decides whether the plate sits flush.
Key Specifications
| Parameter | KEL grommet frame | KEL-BES brush plate |
|---|---|---|
| Protection | IP54 to EN 60529 with the flat gasket and the correct grommets | Dust and particle screening, reduced airflow, no water seal |
| UL type | UL Type 12 to UL 50E | Not rated for water |
| Frame material | Polyamide, UL94 V-0, self extinguishing | Polyamide frame, polyamide brushes, UL94 V-0 |
| Screw material | Zinc plated steel, or V2A stainless on the .200 variants | Zinc plated steel brush profile |
| Operating temperature | -40 C to +140 C static | -20 C to +90 C |
| Mounting height | 17 mm | 10 mm |
| Cut-out sizes | 112 x 36, 112 x 66, 112 x 82, 112 x 126, 86 x 126, 65 x 36, 46 x 46 mm | 112 x 36, 86 x 36, 65 x 36 mm, plus M50 round |
| Screw holes | 4, 6 or 8 holes at 5.8 mm diameter, depending on frame length | 4 holes at 5.8 mm diameter |
| Gasket | Flat rubber gasket included | None, brush seal only |
| Grommet system | KT small up to 17 mm, KT large up to 35 mm, split for pre-terminated cable | Brush rows, no grommets |
| Cable count | From 1 cable in a KEL-B1 to 120 cables in a double middle frame | Continuous brush slot, cable count limited by slot width |
| Properties | Vibration proof, halogen free, silicone free, UV resistant | Halogen free, silicone free, visual screening |
Included Models and Order Codes
The frames below carry the cut-out, the cable count and the grommet set that ships with them. A frame is ordered by part number together with the grommets, because a KT small grommet takes one cable up to 17 mm or four thin cables, and the cable count in the table assumes the four way use. The .200 suffix is the same frame with V2A screws for washdown and coastal cabinets.
| Part Number | Type | Cut-out (mm) | Max cables | Max cable dia | Frame L x W x H (mm) | Grommets supplied | Screw material |
|---|---|---|---|---|---|---|---|
| 42241 | KEL 24|10 | 112 x 36 | 40 | 17 mm | 147 x 58 x 17 | 10 x KT small | Steel, zinc plated |
| 42241.200 | KEL 24|10 V2A | 112 x 36 | 40 | 17 mm | 147 x 58 x 17 | 10 x KT small | Stainless V2A |
| 42247 | KEL 24|7 | 112 x 36 | 25 | 35 mm | 147 x 58 x 17 | 6 x KT small, 1 x KT large | Steel, zinc plated |
| 42248 | KEL 24|5 | 112 x 36 | 20 | 35 mm | 147 x 58 x 17 | 5 x KT small | Steel, zinc plated |
| 42244 | KEL 24|4 | 112 x 36 | 10 | 35 mm | 147 x 58 x 17 | 2 x KT small, 2 x KT large | Steel, zinc plated |
| 42216 | KEL 10|6 | 65 x 36 | 24 | 17 mm | 98 x 58 x 17 | 6 x KT small | Steel, zinc plated |
| 42212 | KEL 10|3 | 65 x 36 | 9 | 35 mm | 98 x 58 x 17 | 2 x KT small, 1 x KT large | Steel, zinc plated |
| 42204 | KEL-B4 | 46 x 46 | 16 | 17 mm | 72 x 58 x 17 | 4 x KT small | Steel, zinc plated |
| 42206 | KEL-B1 | 46 x 46 | 1 | 35 mm | 72 x 58 x 17 | 1 x KT large | Steel, zinc plated |
| 42206.200 | KEL-B1 V2A | 46 x 46 | 1 | 35 mm | 72 x 58 x 17 | 1 x KT large | Stainless V2A |
Brush Plates on the Same Cut-outs
A brush plate fits the same rectangle as the grommet frame, so a cabinet that was prepared for a KEL 24 can take a KEL-BES 24 without a new cut-out. The brushes are polyamide and the frame is 10 mm deep, which leaves more room behind the plate than the 17 mm grommet frame. The M50 version is round and split, so it can be snapped into a metric knockout or fixed with a locknut.
| Part Number | Type | Cut-out (mm) | Plate L x W x H (mm) | Mounting | Frame material |
|---|---|---|---|---|---|
| 51505 | KEL-BES 10 | 65 x 36 | 100 x 58 x 10 | 4 screws or expanding rivets | Polyamide, UL94 V-0 |
| 51510 | KEL-BES 16 | 86 x 36 | 120 x 58 x 10 | 4 screws or expanding rivets | Polyamide, UL94 V-0 |
| 51515 | KEL-BES 24 | 112 x 36 | 147 x 58 x 10 | 4 screws or expanding rivets | Polyamide, UL94 V-0 |
| 51540 | KEL-BES-S 50 | M50 x 1.5 round | Round, split | Snap in or locknut | Polycarbonate, UL94 V-0 |
Key Features
Cut-outs that match connectors – 112 x 36 mm for a 24 pin connector, 86 x 36 mm for 16 pin, 65 x 36 mm for 10 pin, and 46 x 46 mm for a measuring instrument.
Split frame, split grommet – The frame opens in the middle and each grommet is slit, so a moulded plug passes through and the cable is laid in from the side.
IP54 with the supplied gasket – A flat rubber gasket ships with every frame, and the seal is certified to EN 60529 once the correct KT grommet is fitted around each cable.
Stainless option on the same frame – The .200 variants swap the zinc plated screws for V2A, which is what a washdown cabinet or a coastal site needs.
Four frame lengths – 58 mm, 83 mm, 102 mm and 146 mm, covering cut-outs from 36 mm to 126 mm high, so the plate grows with the harness.
Brush plate for airflow – Polyamide brushes screen dust, hair and swarf while leaving the opening open to air, which suits fan cooled cabinets and raised floors.
Strain relief to EN 62444 – The grommet grips the jacket, so a cable that is pulled from outside does not load the terminal inside the cabinet.
Depth on the datasheet – 17 mm for the grommet frame and 10 mm for the brush plate, both measured from the mounting face, which is the number that fits a shallow base.
Applications
These plates are used wherever a pre-terminated harness enters a metal enclosure. The four cases below cover most orders, and each one changes which frame is correct.
Machine tools and control cabinets – A 24 pin connector on a motor cable needs the 112 x 36 mm frame, and the IP54 gasket keeps coolant mist away from the terminals.
Telecom and server racks – Brush plates on a raised floor let patch cords pass while stopping dust, and the visual screening hides the cable bundle from the aisle.
Washdown food and pharma cabinets – V2A screws and a stainless frame option survive cleaning chemicals, and the flat gasket is replaced at each service interval.
Outdoor kiosks and traffic cabinets – A 46 x 46 mm frame takes a single antenna or sensor cable through a small base plate without a round gland.
A cabinet base is cut once, so the frame, the gasket and the grommet set are checked together on the SUPERB PCB drawing before the plate is released. On the SUPERB PCBA build the harness is closed into the grommets on the bench and the plate is the last item fitted, which keeps swarf out of the sealed side of the cabinet.
Sourcing and Cross-Reference
A cable entry plate is a small part that holds up a whole build, because the cabinet has to be cut before the plate is ordered. The cut-out is the first thing to confirm, then the frame that fits it, then the grommet set that matches the cables. A frame ordered without grommets arrives as an empty rectangle.
The two families share cut-outs but not ratings. A brush plate does not seal against water, and a grommet frame does not pass air. Where a cabinet needs both, the usual arrangement is a grommet frame for the power and signal cables and a brush plate on a separate cut-out for the airflow path.
Frames are supplied with the gasket and the screws, and the grommets are ordered by size. KT small covers cables up to 17 mm and KT large up to 35 mm, both split for pre-terminated cable. Spare grommets are worth keeping on the order, because a grommet that is cut too short on site leaves a gap in the seal.
SUPERB Assembly fits each grommet around its cable, checks that the jacket sits inside the slit and torques the four frame screws, because a gasket that is pinched at one corner leaks at the opposite corner.
Q: Can you supply the KEL 24|10 frame in V2A with ten KT small grommets, and a KEL-BES 24 brush plate that fits the same 112 x 36 mm cut-out?
A: Send the connector type, the number of cables, the largest cable diameter and the cut-out you can punch. The SUPERB Tech desk replies with the frame, the grommet set and the brush plate that share that cut-out, so the cabinet is cut once.
Why Buy Cable Entry Plates Through SUPERB
- Cut-out checked before the order: The connector footprint and the plate cut-out are compared in writing, because a frame that is one size out means the cabinet base is scrapped.
- Grommets quoted with the frame: KT small and KT large are added to the same line, so the plate arrives complete and the harness can be closed on the bench.
- Two ratings from one stock point: IP54 grommet frames and brush plates on the same cut-outs, which keeps a mixed cabinet on one mounting pattern.
- Stainless and zinc on the same part number: The .200 suffix is quoted when the site is washed down, without changing the cut-out or the grommets.
- Harness assembly support: The assembly team closes the grommets around the cable on the bench and labels each plate, so the cabinet builder only has to screw the frame down.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Cable Glands and Strain Relief Bushings for Enclosure Entries, Nylon Grommets and Hole Plugs for Panel Openings, Cable Clamps and Harness Ties for Internal Wiring, Breather Vents and Pressure Equalization Plugs, Screw Terminal Blocks and Pluggable Connectors, Kitting Service for Harness and Panel Builds.