Cable Glands and Strain Relief Bushings for Enclosure Entries
Product Specifications
Product Overview
A cable gland does three jobs at the entry point of an enclosure: it seals the hole against water and dust, it clamps the cable jacket so a pull on the cable does not reach the terminals, and on a metal case it bonds the cable shield to the wall. The parts on this page are split into two families. The metal glands are threaded bodies that go through a tapped or punched hole with a locknut and a dome nut, and the nylon bushings are one piece parts that snap into a punched hole and grip the cable with an internal ratchet.
The Hummel HSK-M family is the metal gland we quote most often. The body is nickel plated brass, the clamping insert is polyamide V0 to UL94, the seal and the O-ring are NBR. The rating is IP68 at 10 bar for 30 minutes and IP69K, with a NEMA type rating of 4, 4X and 6, and the working range is -40 to +100 C. That combination is what makes it usable on an outdoor telecom cabinet and on a machine tool cabinet at the same time, because the IP69K part survives the wash down that a NEMA 4 part alone does not.
The figure that is misread most often on a gland is the thread size. An M12 thread exists in two clamping ranges, 2 to 5 mm and 3 to 6.5 mm, and the same is true of M16, M20 and M32. The thread decides whether the gland fits the hole, and the clamping insert decides whether it holds the cable. A 6 mm cable in a 2 to 5 mm insert is not clamped, the seal is stretched over the jacket instead of compressed against it, and the entry fails a pull test even though the thread is correct. That is why the table below lists the cable range next to every order code rather than one range for the family.
The torque figure is the second number that is treated as a formality. The M12 body takes 4 Nm, the M16 takes 5 or 6 Nm depending on the insert, the M20 takes 8 or 10 Nm, the M25 takes 12 Nm and the M32 takes 15 Nm. Under torque leaves a gap between the seal and the wall that shows up as a drip in an IP test, and over torque crushes the polyamide insert so the grip on the jacket is lost and the seal is pushed off the cable. A setting wrench is the only way to hold that number on a line.
The nylon bushings are the other half of the page. Heyco Original Strain Relief bushings are one piece nylon parts that snap into a punched hole, with a flat on the body that stops the part turning and a ratchet inside that grips the jacket. The 6N series takes a 15.9 mm hole and a panel up to 1.6 mm, the 6P version of the same body takes a 3.2 mm panel, the 7N series takes a 19.0 mm hole for a thicker cord, and the 5KN part is the flat cable version with a 4.8 by 8.9 mm opening. These are used where the cord is moulded to the product and there is no room for a locknut inside the case.
The choice between the two families is not a price decision. A metal gland is used where the cable carries a shield that has to be bonded to the chassis, where the entry has to survive wash down, or where the wall is thick enough to take a thread. A nylon bushing is used on a double insulated plastic case with a moulded cord, where the entry only has to stop a pull on the cord from reaching the solder joint. Both are stocked against the same question, which is the outer diameter of the cable.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Body material | Nickel plated brass | HSK-M metal glands |
| Clamping insert | Polyamide V0 to UL94 | HSK-M metal glands |
| Seal and O-ring | NBR | HSK-M metal glands |
| Protection class | IP68 at 10 bar for 30 minutes, IP69K | HSK-M metal glands |
| NEMA type rating | 4, 4X, 6 | HSK-M metal glands |
| Operating range | -40 to +100 C | HSK-M metal glands |
| Thread standards | Metric, PG, NPT | HSK-M family |
| Metric thread range | M12 x 1.5 to M63 x 1.5 | HSK-M family |
| Cable range | 2 mm to 44 mm depending on the body | HSK-M family |
| Tightening torque | 4 Nm at M12, 5 to 6 Nm at M16, 8 to 10 Nm at M20, 12 Nm at M25, 15 Nm at M32 | HSK-M metric |
| Bushing material | Nylon, black | Heyco Original Strain Relief |
| Bushing mounting hole | 14.3 mm, 15.9 mm or 19.0 mm | 5KN, 6N, 7N series |
| Bushing panel thickness | 1.6 mm or 3.2 mm, by series | 6N and 6P, 7N and 7P |
| Bushing cable opening | 7.6 mm to 10.9 mm round, 4.8 by 8.9 mm flat | 6N, 7N, 5KN |
| Bushing body length | 14.7 mm or 19.1 mm | 6N, 7N |
Included Models and Order Codes
The rows below are the entries we quote most often. Panel or wall thickness is given per part because the same thread comes in a thin wall and a thick wall version, and a dash means the maker does not publish that figure.
| Part Number | Thread or Hole | Cable Range | Panel or Wall | Wrench or Anti-Rotation | Torque | Notes |
|---|---|---|---|---|---|---|
| 1.609.1200.50 | M12 x 1.5 | 3 to 6.5 mm | 6.5 mm thread length | 14 / 14 mm | 4 Nm | IP68 and IP69K, 19 mm high |
| 1.609.1200.51 | M12 x 1.5 | 2 to 5 mm | 6.5 mm thread length | 14 / 14 mm | 4 Nm | Small insert on the same M12 body |
| 1.609.1600.50 | M16 x 1.5 | 4 to 8 mm | 6 mm thread length | 17 / 19 mm | 6 Nm | 21 mm high |
| 1.609.1600.51 | M16 x 1.5 | 2 to 6 mm | 6 mm thread length | 17 / 19 mm | 6 Nm | Small insert on the same M16 body |
| 1.609.1611.50 | M16 x 1.5 | 5 to 10 mm | 6 mm thread length | 20 / 20 mm | 5 Nm | Wide insert, 22 mm high |
| 1.609.2000.50 | M20 x 1.5 | 6 to 12 mm | 6 mm thread length | 22 / 22 mm | 8 Nm | 23 mm high |
| 1.609.2016.50 | M20 x 1.5 | 10 to 14 mm | 6 mm thread length | 24 / 24 mm | 10 Nm | 24 mm high |
| 1.609.2500.50 | M25 x 1.5 | 13 to 18 mm | 7 mm thread length | 30 / 30 mm | 12 Nm | 26 mm high |
| 1.609.3200.50 | M32 x 1.5 | 18 to 25 mm | 8 mm thread length | 40 / 40 mm | 15 Nm | 31 mm high |
| SR 6N-4 (1217) | 15.9 mm hole | 7.6 mm round | 1.6 mm panel | 14.0 mm flat | - | Nylon bushing, 14.7 mm body |
| SR 6N3-4 (1200) | 15.9 mm hole | 8.3 to 9.1 mm | 1.6 mm panel | 14.0 mm flat | - | Nylon bushing, 14.7 mm body |
| SR 6P-4 (1210) | 15.9 mm hole | 7.6 mm round | 3.2 mm panel | 14.0 mm flat | - | Thick panel version of the 6N-4 |
| SR 7N-2 (1244) | 19.0 mm hole | 9.0 to 10.9 mm | 1.6 mm panel | 16.8 mm flat | - | Nylon bushing, 19.1 mm body |
| SR 5KN-4 (1170) | 14.3 mm hole | 4.8 by 8.9 mm flat | 1.6 mm panel | 13.5 mm flat | - | Flat cable, straight through |
Key Features
Torque listed per body – The 4 Nm, 5 to 6 Nm, 8 to 10 Nm, 12 Nm and 15 Nm figures are given per thread, because a gland torqued by feel either leaks or crushes its insert.
Two clamping ranges per thread – M12, M16, M20 and M32 each come in a small and a wide insert, so a 5 mm cable is not clamped by a 6 to 12 mm insert.
IP68 and IP69K in one part – The metal glands hold 10 bar for 30 minutes and take the close range high pressure spray, with a NEMA 4, 4X and 6 type rating.
Metal body, polyamide insert – A nickel plated brass body with a V0 insert holds the seal square on a wall that is not perfectly flat, which a rigid plastic gland does not.
Nylon bushings for punched holes – The 5KN, 6N and 7N parts need no locknut and no thread, so a plastic case is punched and the bushing is pressed in from the outside.
Panel thickness split – The 6N and 6P versions of the same bushing body take a 1.6 mm and a 3.2 mm panel, which is the difference between a flush fit and a loose one.
Applications
These entries are used where a cable has to cross an enclosure wall and stay sealed and strain relieved for the life of the product.
Outdoor telecom and radio cabinets – A shielded cable enters a metal wall through an M16 or M20 gland, the shield is bonded at the body, and the entry holds IP68 through a wet season.
Machine control and motor cabinets – A motor cable enters a cabinet that is washed down, with the M25 or M32 body taking the jacket load so the terminal block sees no pull.
Handheld and portable instruments – A moulded cord enters a plastic case through a nylon bushing in a 15.9 mm punched hole, with the internal ratchet taking the pull instead of the solder joint.
The gland is fitted to the wall before the SUPERB PCB goes in, because the nut has to be reached from the inside of the case and the harness is already crimped by then. On the SUPERB PCBA route the cable length is cut to the finished distance from the gland to the terminal, not to the length of the spool.
Sourcing and Cross-Reference
A cable entry is bought by thread and approved by cable range. When a gland is replaced on an existing box, we ask for the outer diameter of the cable, the wall thickness at the hole and the thread that is already there, and we match the insert before the body. That order of questions stops the common mismatch, which is a correct M16 body with an insert that is 2 mm too wide for the jacket.
Thread standards are the second trap. A PG thread and a metric thread of similar size are not interchangeable, and an older instrument will often have PG 11 or PG 16 where a new one has M16 or M20. The HSK-M family is published in metric, PG and NPT on the same body, so a replacement for a PG entry does not need an adapter. Where a part is no longer offered in the original thread, an adapter or a different body is the honest answer, not a metric gland forced into a PG hole.
The nylon bushings are usually ordered by the Heyco code rather than by size, because the code carries the panel thickness and the cable opening. The number in brackets on the table, 1217, 1200, 1210, 1244 and 1170, is the Heyco part number for the black part, and the SR code is what an engineer usually quotes. Where a bushing has been discontinued in one colour, the black version is normally still available, and we say so rather than substituting a different body.
SUPERB Assembly fits the gland, pulls the harness through and then torques the dome nut with a setting wrench, because a gland tightened by hand on a production line leaks on the first rain test.
Q: Can you supply an M16 gland for a 7 mm cable with an IP68 rating, and confirm the torque and the wall thickness it needs before we punch the case?
A: Send the cable outer diameter, the wall thickness and the thread the enclosure already has. The SUPERB Tech desk confirms the clamping range and the torque before the wall is punched, because an M16 thread comes in two cable ranges and only one of them grips a 7 mm cable.
Why Buy Cable Entries Through SUPERB
- Insert matched to the cable: The order is built from the cable outer diameter and the panel thickness, which is where a sealing entry usually fails.
- Torque stated per thread: The tightening figures are listed per body so the gland is set with a wrench rather than by hand.
- Metric, PG and NPT in one family: An older PG entry is replaced without an adapter, and the thread on the drawing is confirmed before the box is punched.
- Metal and nylon both quoted: A shielded metal wall and a double insulated plastic case are served from the same desk rather than from two orders.
- Fitted and torqued at assembly: The entry is pulled through and set with a wrench on the line, so the first IP test is not the first time the torque is applied.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: DIN and Circular Connectors for Panel Wiring, Screw Terminal Blocks and Pluggable Connectors for Field Wiring, Wire to Board Crimp Housings and Headers for Harness Builds, RF Coaxial Connectors and Adapters for Test and Antenna Runs, Obsolete Part Cross Reference Hub.