DIN Rail Terminal Blocks for Control Panel Wiring
Product Specifications
Product Overview
A DIN rail terminal block is the point where the panel stops being a set of components and becomes a wiring schedule. The strip carries the current, the marker carries the address, and the plate between groups carries the creepage distance. The terminal itself has to do all three without getting wider than the pitch allows.
The UT family is the screw terminal with a spring-loaded pressure plate, so the conductor is clamped without the screw turning the wire. UT 2,5 is 5.2 mm wide and rated 1000 V at 24 A; UT 4 is 6.2 mm at 32 A; UT 6 is 8.2 mm at 41 A, with a maximum load current of 57 A on 10 mm2 conductor. The UK family is the older screw terminal that also fits NS 32 rail, which keeps older panels serviceable.
Current ratings have two numbers and they are not interchangeable. The nominal current is the continuous rating at the rated cross section; the maximum load current is the short term figure at a larger conductor. A 4 mm2 strip rated 32 A nominal can carry 41 A only with a 6 mm2 conductor, and the panel schedule has to say which one is being used.
Key Specifications
| Family | Nominal voltage | Nominal current | Cross section | AWG | Width | Connection |
|---|---|---|---|---|---|---|
| UT 2,5 | 1000 V | 24 A | 0.14 - 4 mm2 | 26 - 12 | 5.2 mm | Screw |
| UT 2,5-PE | Protective conductor | - | 0.14 - 4 mm2 | 26 - 12 | 5.2 mm | Screw |
| UT 4 | 1000 V | 32 A | 0.14 - 6 mm2 | 26 - 10 | 6.2 mm | Screw |
| UT 6 | 1000 V | 41 A | 0.2 - 10 mm2 | 24 - 8 | 8.2 mm | Screw |
| UT 6-PE | Protective conductor | - | 0.2 - 10 mm2 | 24 - 8 | 8.2 mm | Screw |
| UK 5 N | 800 V | 32 A | 0.2 - 6 mm2 | - | 6.2 mm | Screw |
| UK 5 N, cUL | 600 V | 30 A | 0.2 - 4 mm2 | 30 - 10 | 6.2 mm | Screw |
| WDU 2.5 | 800 V | 24 A | 2.5 mm2 | - | - | Screw |
Included Models and Order Codes
Order codes below cover the feed-through and PE terminals in the widths that carry most panel wiring. A PE terminal shares the width of its feed-through partner, so the strip stays square when the earth is added.
| Part number | Type | Width | Colour | Rated data |
|---|---|---|---|---|
| 3044076 | UT 2,5 | 5.2 mm | Grey | 1000 V, 24 A, 4 mm2 |
| 3044092 | UT 2,5-PE | 5.2 mm | Green-yellow | PE, 4 mm2 |
| 3044102 | UT 4 | 6.2 mm | Grey | 1000 V, 32 A, 6 mm2 |
| 3044131 | UT 6 | 8.2 mm | Grey | 1000 V, 41 A, 10 mm2 |
| 3044157 | UT 6-PE | 8.2 mm | Green-yellow | PE, 10 mm2 |
| 3004362 | UK 5 N | 6.2 mm | Grey | 800 V, 32 A, 4 mm2 |
| 1020000000 | WDU 2.5 | - | Dark beige | 800 V, 24 A, 2.5 mm2 |
Matching Covers, Plates and Stops
A strip is not complete without the parts at its ends and between its groups. The cover closes the open side of the last terminal, the plate separates two circuits and the stop holds the strip on the rail.
| Part number | Part | Width | Fits |
|---|---|---|---|
| 3047028 | D-UT 2,5/10 end cover | 2.2 mm | UT 2,5 to UT 10 |
| 3047167 | ATP-UT partition plate | 2.2 mm | UT 2,5 to UT 10 |
| 3003020 | D-UK 4/10 end cover | 1.8 mm | UK 5 N |
| 0800886 | E/NS 35 N end stop | 9.5 mm | NS 35/7,5 and NS 35/15 |
Key Features
Two ratings, both stated – nominal current at the rated cross section and maximum load current at the larger conductor, so the strip is not oversized by mistake.
PE in the same width – the earth terminal shares the pitch of the feed-through, so the strip stays square and the marker lines up.
Screw with a pressure plate – the conductor is clamped by a plate rather than by the screw end, which keeps a stranded wire from spreading.
NS 32 and NS 35 – the UK family fits both rails, which keeps older panels serviceable without changing the rail.
Bridge and marker system – one accessory system covers bridging, marking and testing across the UT family, so the strip does not need mixed parts.
Plate and cover matched by series – the accessories are ordered by terminal family, not by rail, which avoids the 1.8 mm against 2.2 mm mismatch.
Applications
Terminal strips are sized by the schedule. Three patterns repeat.
Control and automation panels – UT 2,5 for 24 V signal wiring and UT 6 for the 400 V feed, with PE terminals at the same pitch.
Machine and drive panels – UT 6 and UT 4 strips for motor feeds, where the maximum load current matters more than the nominal figure.
Retrofit and extension – UK 5 N terminals on existing NS 32 rail, where the strip is being extended and the rail cannot be changed.
A terminal strip is quoted by pole count and wire size, and the SUPERB PCBA and the SUPERB PCB are checked against the same wiring schedule so the strip length and the rail cut match.
Sourcing and Cross-Reference
Order by group, not by strip length. A strip with four groups needs one cover at each end and three plates, and the plate count is what usually falls short on site.
Decide the conductor before the terminal. A 4 mm2 strip on 6 mm2 wire is a rework, and the difference between UT 4 and UT 6 is 2 mm of pitch across the whole run.
Ferrules change the clamp. A stranded wire with a plastic-collar ferrule needs the longer strip length, and a twin ferrule needs the TWIN version of the terminal rather than two wires in one clamp.
Obsolete terminal series are still quoted against the current equivalent. See obsolete part cross reference for the replacement by wire size and pitch.
The SUPERB Assembly team wires from the bottom of the strip and keeps the top clear for the bridge and the marker, which is why the strip is ordered with the covers and plates.
Q: Can you supply the strip assembled with covers and plates?
A: Yes. Send the wire sizes and the number of poles per group; the SUPERB Tech team quotes the strip with the end stops, covers and partition plates.
Why Panel Builders Buy Terminal Blocks From SUPERB
- Rated data checked per family: nominal and maximum current are quoted separately, so the strip is sized on the right number.
- Accessories quoted with the strip: covers, plates and stops arrive with the terminals.
- PE at the same pitch: the earth terminal does not break the marker line.
- Old rail supported: UK terminals for NS 32 panels that are being extended, not replaced.
Related Product Families