Breather Vents and Pressure Equalization Plugs for Sealed Cases

A sealed case is not a stable case: as the inside warms, the pressure rises, the seals are loaded and moist air is drawn in as it cools. The screw in vents here run from an M6 part at 300 ml per minute to an M32 part at 16 litres per minute, which covers a case of 2 litres up to one of 200 litres. Protection runs from IP65 to IP68 at 2 metres for one hour, with IP69K on every part except the smallest, and bodies in polyamide, 316L stainless and polycarbonate. Airflow, torque and through hole diameter are given per part number, because the hole has to be drilled once.
quote now

Product Specifications

Product Overview

A sealed enclosure behaves like a slow balloon. When the equipment inside warms up, the air expands and the internal pressure rises against the gasket. When it cools, the pressure falls and the case pulls air in through the weakest point, which is usually the gasket or the cable gland. That cycle repeats every day, and the water that comes in with the air condenses on the coldest surface, which is often the board. The vent is the part that gives the air a path in and out through a membrane that blocks liquid water and dust, so the pressure stays close to ambient and the gasket is not asked to work as a pump.

The parts on this page are the GORE PolyVent screw in series, which is the family used where the case has a machined or moulded boss for a thread. The XS part PMF100600 is an M6 by 0.75 vent with 300 ml per minute of airflow at a 70 mbar differential, a 10 mm wrench size and a torque of 0.3 Nm, for a case up to about 2 litres. The Standard parts are M12 by 1 and M12 by 1.5, in black or gray, at 450 ml per minute and 0.7 Nm, with a 16 mm wrench and a 12.2 mm through hole on the M12 by 1.5 version. Those two figures, the thread and the through hole, are what the drawing has to carry before anything is drilled.

Airflow is the figure that is chosen against the volume of the case and the rate at which it changes temperature. A vent that is too small still equalizes pressure, but it does so slowly, and a slow vent on a case that is washed hot and then rained on is a case that sees a pressure differential for minutes at a time. The High Airflow parts PMF100585 and PMF100586 give 4000 ml per minute on the same M12 by 1.5 thread, and the High Airflow PRO parts PMF300680 and PMF300681 give 7600 ml per minute at a 1.0 Nm torque. For a large cabinet the XL part PMF200542 is an M32 by 1.5 vent in polycarbonate at 16 litres per minute at a 12 mbar differential, with a 33 mm through hole and a 5 Nm torque.

The membrane is expanded PTFE and it is oleophobic as well as hydrophobic on every part listed here, which matters on a case that sits near oil mist, hydraulic fluid or cutting fluid. A hydrophobic membrane passes air and blocks water, and an oleophobic one also resists wetting by oils, which is the failure mode that turns a vent into a plug over a year. The body and cap are polyamide on the plastic parts and 316L stainless on PMF200444 and PMF200400, and the O ring is silicone at 60 Shore A throughout. Body, cap and O ring are all rated UL94 V-0, which is the figure a safety review asks for on a plastic part inside a case.

Installation is where most of these parts are lost. The vent goes on a flat vertical face with the cap to the outside, so water runs off instead of pooling in the cap and sitting on the membrane for days. The hole is drilled to the published diameter and chamfered, and the torque is set to the figure for that part: 0.3 Nm on the M6, 0.7 Nm on the Standard and High Airflow parts, 1.0 Nm on the High Airflow PRO, 0.9 Nm on the stainless parts and 5 Nm on the XL. A vent over tightened on a plastic boss cracks at the thread root, and a vent under tightened weeps past the O ring. A torque wrench is the difference between the two.

The last figure is the protection level, and it is worth reading carefully. Every part here meets IP65 to IP68, with the immersion test at 2 metres for one hour and up to 72 hours on the XS part, and IP69K on every part except the XS. IP69K is the high pressure, high temperature wash, which is the test that a food or pharmaceutical case has to pass. The stainless part PMF200444 adds IK10 impact resistance when it is fitted at the higher 5.0 Nm torque on a 60 degree chamfer, and PMF200400 carries the ATEX and IECEx classification for explosive atmospheres. Those are the two cases where the vent is not just a vent but a certified component.

Key Specifications

ParameterValueApplies to
Vent typeScrew in, cap to the outside of the caseAll parts on this page
Thread sizesM6 x 0.75, M12 x 1, M12 x 1.5, M32 x 1.5By part
MembraneExpanded PTFE, oleophobicAll parts on this page
Body and cap materialPolyamide, 316L stainless steel, polycarbonateBy part
O ringSilicone, 60 Shore AAll parts on this page
FlammabilityUL94 V-0 body, cap and O ringAll parts on this page
Ingress protectionIP65, IP66, IP67, IP68 at 2 m for 1 hourAll parts
High pressure washIP69KAll parts except PolyVent XS
Temperature rangeMinus 40 to plus 125 C, plus 150 C on XSAll parts
Airflow300 ml per minute to 16 litres per minuteAt 70 mbar, XL at 12 mbar
Installation torque0.3 Nm to 5 NmBy part
Through hole diameter6.2 mm, 12.2 mm, 33 mmBy thread
Wrench size10 mm, 16 mm, 18 mm, 70 mmBy part
Counter nutStainless 304, plastic, nickel plated brassBy part
TraceabilityLaser marked per part, DMC on High Airflow PROM6 and M12 parts

Included Models and Order Codes

The rows below are the screw in vents we quote most often. Thread, airflow, torque and through hole are given per part number because the hole is drilled once, and a dash means the maker does not publish that figure for that thread.

Part NumberSeriesThreadAirflowTorqueThrough HoleNotes
PMF100600PolyVent XSM6 x 0.75300 ml per minute0.3 Nm6.2 mm10 mm wrench, black, 150 C
PMF100318StandardM12 x 1450 ml per minute0.7 Nm-Black, 16 mm wrench
PMF100319StandardM12 x 1450 ml per minute0.7 Nm-Gray RAL 7035, 16 mm wrench
PMF100320StandardM12 x 1.5450 ml per minute0.7 Nm12.2 mmBlack, 16 mm wrench
PMF100321StandardM12 x 1.5450 ml per minute0.7 Nm12.2 mmGray, 16 mm wrench
PMF100585High AirflowM12 x 1.54000 ml per minute0.7 Nm12.2 mmBlack, case up to 50 l
PMF100586High AirflowM12 x 1.54000 ml per minute0.7 Nm12.2 mmGray, case up to 50 l
PMF300670High Airflow PROM12 x 17600 ml per minute0.7 Nm-Black, DMC marked
PMF300671High Airflow PROM12 x 17600 ml per minute0.7 Nm-Gray, DMC marked
PMF300680High Airflow PROM12 x 1.57600 ml per minute1.0 Nm12.2 mmBlack, DMC marked
PMF300681High Airflow PROM12 x 1.57600 ml per minute1.0 Nm12.2 mmGray, DMC marked
PMF200444Stainless SteelM12 x 1.51600 ml per minute0.9 Nm, 5.0 Nm for IK1012.2 mm316L, IK10 at 5 Nm, 18 mm wrench
PMF200400Ex+M12 x 1.51600 ml per minute0.9 Nm-316L, ATEX and IECEx ex eb, 18 mm wrench
PMF200542XLM32 x 1.516 litres per minute5 Nm33 mmPolycarbonate, 12 mbar reference, 70 mm wrench

Counter Nuts and Mounting Accessories

A vent in a thin or moulded wall is held by a counter nut on the inside. The nut has to match the thread and the material of the vent, because a brass nut on a stainless body is a corrosion pair.

Part NumberItemThreadMaterialUsed With
M10510-017Counter nutM6Stainless steel 304PMF100600
M10510-009Counter nutM12Plastic, grayStandard, High Airflow, High Airflow PRO
M10510-008Counter nutM12Nickel plated brassPMF200444 stainless steel vent
M10510-010Counter nutM32Plastic, grayPMF200542 XL vent

Key Features

Airflow stated per part – 300 ml per minute to 16 litres per minute is given for each part, so a 50 litre case is not fitted with a vent sized for 2 litres.

IP68 and IP69K – Immersion at 2 metres for one hour and the high pressure wash are both listed, which is what a washdown case has to show.

Oleophobic membrane – Every part on the page resists oil wetting as well as water, which is the failure mode on a case near cutting fluid or hydraulics.

Torque in the table – 0.3 Nm to 5 Nm is given per part, because a plastic boss cracks at the thread root when a vent is tightened by feel.

Through hole diameter – 6.2 mm, 12.2 mm and 33 mm are listed by thread, so the hole is drilled once and chamfered before the vent arrives.

Certified options – ATEX and IECEx on the Ex+ part and IK10 impact on the stainless part, for the cases where the vent is a certified component.

Applications

These parts are used on any case that is sealed against water and dust and still has to breathe.

Outdoor telecom and radio units – An M12 by 1.5 High Airflow vent at 4000 ml per minute keeps a 50 litre cabinet close to ambient through a day and night cycle, so the gasket is not pumped.

Washdown and food area enclosures – A stainless vent at IP69K takes the high pressure wash, with the 316L body resisting the cleaning chemicals that would attack a plated part.

Portable and battery cases – An M6 XS vent at 300 ml per minute gives a 2 litre case a pressure path, which is what stops a sealed battery case from drawing moist air past its seal as it cools.

A vent is the one opening in a sealed case that is meant to pass air, so its position is fixed on the SUPERB PCB drawing and on the case model at the same time. On the SUPERB PCBA route the vent is fitted after the wash and the dry, because a membrane that sees a solvent bath before it is screwed in is a membrane that has already been challenged.

Sourcing and Cross-Reference

A vent is bought by case volume and approved by thread. When a vent is replaced, the thread and the through hole are the two figures to check first, because an M12 by 1.5 vent and an M12 by 1 vent look alike in a bag and only one of them will start in the boss that is already tapped. We ask for the volume of the case, the wall thickness and the wash or immersion the case has to survive, and the part is chosen from those figures rather than from the size of the case.

The second point is the airflow. A vent that is too small equalizes pressure slowly, and a slow vent on a case that goes from a hot wash to a cold yard sees a pressure differential for minutes at a time, which loads the gasket and pulls at the cable glands. The High Airflow and High Airflow PRO parts exist for that reason, and the airflow figure in the table is quoted at a 70 mbar differential so that the parts can be compared with each other.

The third point is the installation. A vent on a horizontal top face collects water in the cap, and a vent fitted without a chamfer sits on an edge rather than on the O ring. Where the wall is thin or moulded, the counter nut goes on the inside and has to match the body material, because a brass nut on a stainless vent is a corrosion pair that shows up as a weep after the first winter. We quote the vent with its nut and its torque, and the drawing carries the hole diameter and the chamfer.

SUPERB Assembly fits the vent with a torque wrench at the figure on the drawing and on a vertical face, because a vent over tightened cracks the body and a vent on a horizontal top collects water in the cap.

Q: Can you supply an M12 by 1.5 vent with 4000 ml per minute of airflow for a 50 litre case, and confirm the through hole diameter, the torque and the counter nut?

A: Send the case volume, the wall thickness and the wash or immersion the case has to survive. The SUPERB Tech desk quotes the vent with its airflow and its torque, because a 2 l case and a 50 l case need different airflow and a vent in the wrong thread needs a new hole.

Why Buy Breather Vents Through SUPERB

  1. Case volume against airflow: The vent is quoted from the volume and the temperature cycle, so a 50 litre cabinet does not get a part sized for 2 litres.
  2. Thread and hole together: The thread and the through hole diameter come from the same table, so the boss is tapped and the hole is drilled once.
  3. Torque stated: The installation torque is given per part, because a vent cracked at the thread root is a leak that only shows up in the rain test.
  4. Membrane chemistry: Oleophobic ePTFE is specified on every part, so a case near oil mist does not lose its vent to wetting.
  5. Fitted after the wash: The vent goes on after cleaning and drying, which is what keeps a membrane from being challenged before it is in service.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Cable Glands and Strain Relief Bushings for Enclosure Entries, EMI Shielding Cans and Contact Gaskets for RF Boards, Fan Guards and Filter Screens for Enclosure Cooling, Rubber Bumpers and Feet for Enclosure Support, Obsolete Part Cross Reference Hub, How to Verify a Drop in Replacement.