Wire to Board Crimp Housings and Headers for Harness Builds
Product Specifications
Product Overview
A wire to board connector is three parts, not one: a header soldered to the board, a housing that holds the wires, and a crimp terminal on each wire that snaps into the housing. Customers quote a housing part number and expect it to work, and it does, but only with the terminal from the same series and the header from the same series. The three are sold separately, and mixing them is the most common way a harness fails at first article. The parts on this page are listed with the series named on every row so the three can be matched before an order is placed.
Pitch sets the current ceiling, and the ceiling falls quickly as the pitch shrinks. A 1.25 mm PicoBlade contact is rated 1 A and takes 28 to 32 AWG wire; at 32 AWG the rating itself drops to 0.8 A. A 1.5 mm ZH contact is 1 A at 50 V with 32 to 26 AWG. A 2.0 mm PH contact is 2 A at 100 V, a 2.5 mm XH contact is 3 A at 250 V, a 3.00 mm Micro-Fit contact reaches 8.5 A, and a 4.20 mm Mini-Fit Jr contact reaches 9 A at 16 AWG. The step from 3 A to 8.5 A is not the pitch alone: it is the contact area and the wire the contact can accept.
Wire gauge is the figure that decides whether the rating can be used. A 3 A XH contact is rated at AWG 22 and accepts 30 to 22 AWG, so a harness built with 28 AWG wire carries less before the crimp runs warm. A Micro-Fit 3.0 contact takes 20 to 24 AWG with an insulation diameter of 1.85 mm maximum, and the maker's derating table shows 8.5 A at 18 AWG falling to 3.5 A at 30 AWG in a two circuit wire to board joint. That table is the one to use when a customer asks for a current in a small housing, because the headline number assumes the largest wire the contact accepts.
Crimp quality is a process, not a part number. A terminal has a crimp height window from the maker, and a crimp that is too tight cuts strands while a crimp that is too loose leaves a joint that pulls out under vibration. The insulation crimp has its own setting: it must grip the insulation without cutting into it, because a cut insulation is a short waiting to happen. A pull test at first article, at the force the maker specifies for the wire size, is the only cheap check. On a housing with a locking lance, the terminal should click in and resist a light pull backwards; a terminal that slides in without a click has been crimped too wide or has been pushed into the wrong cavity.
Housing features decide how the harness behaves in service. A friction lock holds the housing on the header and is enough for a bench instrument. A positive latch with a thumb release, as on Mini-Fit Jr and Micro-Fit, is what a product needs if the harness is handled. A terminal position assurance device, usually a small clip that seats behind the terminals, stops a half inserted terminal from being pushed out during mating. Keying and polarization prevent a two circuit housing from being plugged in reversed, which matters when one side is a supply rail. None of these features can be added later, so they are chosen with the connector.
The last number to check is the height above the board. ZH mates at 5.9 mm with 3.5 mm depth, PH mates at 8.0 mm with 4.5 mm width, and XH mates at 9.8 mm. On a board that slides into a card guide, or sits under a shield can, that height is what decides between families. The same applies to the footprint: a top entry header stands taller than a side entry header and takes the harness from a different direction, and a right angle header moves the cable exit to the board edge, which is often the only way the harness clears the enclosure.
Key Specifications
| Parameter | Value | Applies to |
|---|---|---|
| Pitch | 1.25 mm, 1.5 mm, 2.0 mm, 2.5 mm, 2.54 mm, 3.00 mm, 4.20 mm | Per series |
| Current per contact | 1 A to 9 A, 13 A maximum on Mini-Fit Jr with 45750 terminals on 16 AWG | Per part number |
| Voltage rating | 50 V, 100 V, 125 V, 250 V, 600 V | Per series |
| Wire range | AWG 32 to AWG 16 | Per part number |
| Insulation diameter | 0.5 to 1.9 mm, 1.85 mm maximum on Micro-Fit 3.0 | Per part number |
| Contact resistance | 10 mOhm on PH, XH and Mini-Fit; 20 mOhm on ZH and KK 254 | Per series |
| Mated height | 5.9 mm ZH, 8.0 mm PH, 9.8 mm XH | Top entry through hole header |
| PCB thickness | 0.6 to 1.2 mm and 1.6 mm on ZH, 0.8 to 1.6 mm on PH, 1.6 mm on XH | Per series |
| Housing material | PA66 UL94 V-0 on JST series, nylon UL94 V-2 or V-0 on Molex series | Per part number |
| Contact material | Phosphor bronze or brass, tin plated, gold on request | Per part number |
| Durability | 30 mating cycles on Micro-Fit 3.0 and Mini-Fit Jr | Per series |
| Operating temperature | -25 to +85 C on JST series, -40 to +105 C on Molex series | Per series |
| Withstanding voltage | 500 VAC on ZH, 800 VAC on PH, 1000 VAC on XH, 1500 VAC on KK 254 | Per series |
Included Models and Order Codes
The rows below are the two circuit parts we quote most often for harness work, with the housing, the crimp terminal and the header named separately. Current and voltage are the maker figures for the series with the wire stated in the notes. A dash means the maker does not publish that value.
| Part Number | Series and Pitch | Type | Current | Voltage | Wire Range | Notes |
|---|---|---|---|---|---|---|
| 51021-0200 | PicoBlade 1.25 mm | Receptacle housing | 1 A | 125 V | 28 to 32 AWG via 50058-8000 | 2 circuits, friction lock, mating header 53047 or 53261 |
| 50058-8000 | PicoBlade 1.25 mm | Crimp terminal, female | 1 A, 0.8 A at 32 AWG | 125 V | 28 to 32 AWG | Tin plated, for 51021 housing |
| ZHR-2 | ZH 1.5 mm | Receptacle housing | 1 A at AWG 26 | 50 V | 32 to 26 AWG | 2 circuits, 5.9 mm mated height, 3.5 mm depth |
| SZH-002T-P0.5 | ZH 1.5 mm | Crimp terminal, female | 1 A 26 AWG | 50 V | 32 to 26 AWG, insulation 0.5 to 1.1 mm | 20 mOhm initial contact resistance, for ZHR housing |
| PHR-2 | PH 2.0 mm | Receptacle housing | 2 A at AWG 24 | 100 V | 32 to 24 AWG | 2 circuits, 8.0 mm mated height, 4.5 mm width |
| SPH-002T-P0.5S | PH 2.0 mm | Crimp terminal, female | 2 A at AWG 24 | 100 V | 0.05 to 0.22 mm2, 30 to 24 AWG | Insulation 0.8 to 1.5 mm, tin plated phosphor bronze |
| SPH-004T-P0.5S | PH 2.0 mm | Crimp terminal, female | 2 A | 100 V | 0.032 to 0.08 mm2, 32 to 28 AWG | For thin wire in a PH housing |
| B2B-PH-K-S | PH 2.0 mm | Header, top entry, through hole | 2 A | 100 V | Header, no wire entry | Mates PHR-2, PCB thickness 0.8 to 1.6 mm |
| S2B-PH-K-S | PH 2.0 mm | Header, side entry, through hole | 2 A | 100 V | Header, no wire entry | Right angle exit toward the board edge |
| XHP-2 | XH 2.5 mm | Receptacle housing | 3 A at AWG 22 | 250 V | 30 to 22 AWG | 2 circuits, 9.8 mm mated height |
| SXH-001T-P0.6 | XH 2.5 mm | Crimp terminal, female | 3 A | 250 V | 0.08 to 0.33 mm2, 28 to 22 AWG | Insulation 0.9 to 1.9 mm, 10 mOhm contact |
| SXH-001T-P0.6N | XH 2.5 mm | Crimp terminal, low insertion force | 3 A | 250 V | 0.13 to 0.33 mm2, 26 to 22 AWG | Lighter insertion, less resistant to vibration |
| 22-01-3027 | KK 254 2.54 mm | Receptacle housing | 4 A with phosphor bronze crimp | 250 V | 22 to 30 AWG via 08-50-0114 | 2 circuits, friction lock, mates 2.54 mm headers |
| 08-50-0114 | KK 254 2.54 mm | Crimp terminal, female | 4 A phosphor bronze, 2.5 A brass | 250 V | 22 to 30 AWG | 20 mOhm, 1500 VAC withstanding |
| 43025-0200 | Micro-Fit 3.0 3.00 mm | Receptacle housing, dual row | 8 A single circuit under UL | 600 V | 20 to 24 AWG via 43030-0007 | 2 circuits, positive latch, -40 to +105 C |
| 43030-0007 | Micro-Fit 3.0 3.00 mm | Crimp terminal, female | 8.5 A maximum per contact | 600 V | 20 to 24 AWG, insulation 1.85 mm maximum | 30 mating cycles, tin over phosphor bronze |
| 39-01-2020 | Mini-Fit Jr 4.20 mm | Receptacle housing, dual row | 9 A at 16 AWG | 600 V | 16 to 24 AWG via 5556 crimp | 2 circuits, thumb latch, 13 A maximum with 45750 terminals |
| 39-00-0039 | Mini-Fit Jr 4.20 mm | Crimp terminal, female | 9 A | 600 V | 18 to 24 AWG | 10 mOhm contact, four point contact |
Key Features
Three parts named – Housing, crimp terminal and mating header are listed as separate rows with the series on each, because a harness needs all three from one family.
Current stated with the wire – Every current figure carries the wire gauge it was measured at, so a 3 A XH rating is not read as 3 A on a 28 AWG wire.
Wire and insulation range – Both the conductor range in AWG and the insulation diameter are given, and the second figure is what decides whether a crimp closes on the wire.
Height above the board – Mated height and depth are listed for the housing rows, because the stack under a cover decides between ZH, PH and XH.
Locking and keying options – Friction lock, positive latch, terminal position assurance and polarization are named per series, since none can be added after the harness is built.
Contact resistance per family – 10 mOhm on PH, XH and Mini-Fit against 20 mOhm on ZH and KK 254, which matters on a low voltage sense line as much as on a power run.
Applications
These connectors cover the harness joints inside instruments, control boxes and small power distribution boards.
Sensor and signal harnesses – A 1.5 mm ZH or a 2.0 mm PH joint takes a small harness from a sensor board to a main board where the connector has to fit under a cover with 6 mm of clearance.
Board to panel power – A 4.20 mm Mini-Fit Jr pair at 9 A carries a 12 V or 24 V feed from a power board to a panel switch, and its thumb latch keeps the joint closed on a unit that is moved.
Field serviceable assemblies – A 3.00 mm Micro-Fit pair at 8.5 A per contact lets a sub assembly be unplugged and replaced in the field, with a latch that an operator can release by hand.
Every harness on a SUPERB PCB starts at a header footprint, and every harness we crimp for a SUPERB PCBA is pulled at first article, so a terminal that sits loose in its housing is found before the unit ships.
Sourcing and Cross-Reference
The hard part of a wire to board shortage is not the housing, it is the set. Housings are moulded in large volumes by several makers, and a housing that looks identical from the outside may take a different terminal, with a different crimp height and a different lance. When a series is short, the safe move is to change the whole set on the board: header, housing and terminal together, in a series that is available. Changing only the housing leaves a terminal that pushes in but does not lock, and that failure shows up in the field rather than at first article.
Second sourcing by pitch alone is the second trap. A 2.0 mm housing from one maker does not take a 2.0 mm terminal from another, and a 2.54 mm KK housing does not take a 2.5 mm XH terminal even though the difference looks like 0.04 mm on a drawing. The reliable cross reference is the mating interface drawing: cavity size, lance position and the header's pin cross section. We quote from the old part number or from a sample of the mated pair, and state which series the replacement belongs to.
Lead time on these parts is usually short, but the harness is not: a housing on the shelf is no use if the terminal is on allocation. Because the two are ordered together, we hold the set and quote it as one line, and where a customer builds harnesses in house we supply the terminal on reel with the crimp height stated so the existing tooling can be set. Where the harness is built here, the pull test and the crimp height are recorded against the wire size at first article.
SUPERB Assembly crimps the housing and the terminal as one set from the same series, because a housing from one family and a terminal from another will push in and then fail a pull test.
Q: Can you supply a housing, terminal and header that mate with the connector already on our board, even if the original series is not available?
A: Pitch, circuits and wire gauge decide it, and the housing and the terminal have to come from the same series; the SUPERB Tech desk quotes both halves plus the mating header so the harness cannot be built from mismatched parts.
Why Buy Wire to Board Connectors Through SUPERB
- Sets, not single parts: Housing, terminal and header are quoted together from one series, so a harness cannot be built from parts that push in but do not lock.
- Wire gauge respected: Current is quoted with the wire it was measured at, and the insulation diameter is checked against the crimp, not just the conductor size.
- Height checked against the enclosure: Mated height and depth are given per series, so the joint is picked against the space that actually exists.
- Crimp height supplied: Where the harness is built in house, the terminal arrives with the maker crimp height so the existing tooling can be set to it.
- Pulled at first article: A harness built in the same house as the board is pull tested against the maker force for its wire size before the batch runs.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Board to Board and FPC Connectors, Screw Terminal Blocks and Pluggable Connectors, Pin Headers and Female Sockets, Battery Holders and Coin Cell Retainers, Pin to Pin Cross Reference.