INA139NA/3K
Product Specifications
INA139NA/3K
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA139NA/3K from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA139NA/3K: high side current shunt monitor with a current output and a 40 V common mode
INA139NA/3K is a unipolar high side current shunt monitor in a SOT-23 body of 5 pins. It measures the drop across a shunt at a common mode voltage between 2.7 V and 40 V and converts it into an output current, so the gain is set by the resistor fitted at the output rather than fixed inside the part. The NA suffix is the five pin SOT-23 and the 3K marking identifies the 3000 piece reel.
Order code and package
| Order code | INA139NA/3K |
| Package | 5-pin SOT-23, 2.9 mm by 1.6 mm |
| Packing | tape and reel, 3000 pieces |
| Supply and common mode | 2.7 V to 40 V, independent of each other |
| Output | current output, gain set by the load resistor |
| Gain range | 1 to over 100, set by RL |
| Temperature range | minus 40 to plus 125 degrees |
| Input pins | VIN+ and VIN- across the shunt, plus V+ and GND |
Electrical parameters that decide the application
| Quiescent current | 60 microampere typical |
| Transfer | output current equals shunt voltage divided by 1 kilohm |
| Gain equation | VO equals IS times RS times RL divided by 1 kilohm |
| Common mode range | 2.7 V to 40 V, independent of the supply |
| Supply range | 2.7 V to 40 V |
| Absolute maximum input | 75 V on the analog inputs for the INA139 |
| Output compliance | limited by the supply rail minus the output stage headroom |
Family variants and how they differ
| INA139 | 40 V common mode, minus 40 to plus 125 degrees, this order code |
| INA169 | 60 V common mode, minus 40 to plus 85 degrees |
| INA139NA/3K | 3000 piece reel in the five pin SOT-23 |
| INA139NA/250 | 250 piece reel of the same part |
Points to check before this part goes on a BOM
The output is a current, not a voltage, and that is the whole character of this part. The transconductance is fixed by the internal 1 kilohm resistor, so a 100 mV shunt drop becomes 100 microampere, and the gain is the value of the resistor fitted from OUT to ground: 10 k gives a gain of 10 and 1 k gives unity, which is why the data sheet describes gains from 1 to over 100.
Because the gain is a resistor, the gain error is mostly the resistor tolerance. A 1 percent resistor puts 1 percent on the reading before the amplifier contributes anything, so a build that needs 0.5 percent total accuracy has to start with a 0.1 percent load resistor and a stated temperature coefficient rather than with the amplifier alone.
Common mode and supply are separate inputs on this part, which allows the supply to come from a 3.3 V rail while the shunt sits on a 24 V bus. That is the case the architecture is built for, and it also allows the supply to sit on the opposite side of the shunt with almost no error because the quiescent current is only 60 microampere.
The load resistor has an upper limit that comes from the output compliance, not from the gain table. A 100 k resistor on a 3.3 V supply asks the output stage for 3.3 V at a shunt current that would otherwise be comfortable, so the maximum gain a given rail supports is the rail divided by the largest output current the shunt can produce.
There is no internal filter and no offset trim. A switching supply in the same enclosure couples into the shunt leads, and the 1 kilohm output impedance means a 100 nF capacitor at the output forms a 1.6 kHz pole, which is often enough to clean up a reading without adding an amplifier.
The INA139 is specified to 125 degrees while the INA169 is specified to 85 degrees and reaches 60 V of common mode. A build that needs the higher common mode has to accept the narrower temperature range, and the two order codes are not interchangeable on that basis.
The shunt connections carry the full common mode voltage and a very small differential signal at the same time. Routing the two sense lines as a pair from the shunt terminals rather than from the load side is what keeps the trace resistance out of the reading, and on a 10 milliohm shunt one milliohm of trace is a 10 percent error.
The output current has to go somewhere, and the load resistor sets both the gain and the bandwidth. A 100 k resistor with 10 pF of stray capacitance gives a 160 kHz pole, which is plenty for a supply monitor and not enough for a motor current loop, so the resistor value is a bandwidth decision as much as a gain decision.
Where this order code fits
It is used for high side current monitoring in chargers, portable instruments, telecom equipment, automotive loads and any circuit that measures current on a rail above its own supply. Teams comparing it with a neighbouring part start from our Amplifier Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
What load resistor gives a gain of 50? 50 k. The relation is gain equals RL divided by 1 kilohm, so 50 k gives 50, and the resistor also has to keep the output inside the compliance range of the supply.
Can it measure on the low side? Yes, the common mode range includes ground, but the part is intended for high side use where the supply stays separate from the bus being measured.
Is the output linear near zero? The output stage has a small offset and cannot pull below ground, so the bottom of the range is set by the amplifier offset rather than by the shunt.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.