LT3755EMSE-2#TRPBF
Product Specifications
LT3755EMSE-2#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3755EMSE-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3755EMSE-2: E Grade, 75 V Output, and the Disconnect FET That Protects a String
The LT3755-2 is the 40 V input, 75 V output LED controller with the improved open LED status pin, and the E grade in this order code is guaranteed from 0 C to 125 C junction with the cold data assured by characterisation. The part drives a low side FET from a 7.15 V internal regulator, senses string current at 100 mV on the high side, and includes a gate driver output for a disconnect FET in series with the string. That last function is the one that decides whether a single failed LED takes out a fixture or is simply reported.
Published values
| Parameter | Value |
|---|---|
| Input range | 4.5 V to 40 V, 40 V absolute maximum |
| Output voltage | up to 75 V |
| Current sense threshold | 100 mV full scale, 96 to 103 mV |
| FB regulation | 1.250 V typical, 1.220 to 1.270 V |
| Open LED threshold | 1.200 V, 50 mV below regulation |
| Overvoltage threshold | 1.310 V, 60 mV above regulation |
| PWM dimming | 3000 to 1, PWM pin threshold 1.5 V high and 0.4 V low |
| Switching frequency | 100 kHz to 1 MHz, 170 ns minimum off time |
| Gate drive supply | 7.15 V regulator, 34 mA current limit, 350 mV dropout |
| Quiescent current | 1.4 mA typical, 1.7 mA maximum |
| Shutdown current | 1 uA maximum |
| Package and thermal | 16 lead MSOP, 43 C/W, 125 C maximum junction |
| Grade | E, guaranteed 0 C to 125 C junction |
The disconnect FET is protection, not dimming
PWMOUT is a buffered version of the PWM input driven from the internal 7.15 V rail, and its job is to open a FET in series with the string when the feedback pin rises 60 mV above its regulation point. That is an open LED condition: the string current falls, the boost output climbs, and without a disconnect the output runs to whatever the switch and the diode allow while the surviving LEDs absorb the compliance voltage. With the FET in place the string is opened and the converter idles. The pin is specified to be driven either to ground or to the internal rail, which means the external FET has to be a logic level part with a gate that survives 7.15 V.
This is the difference between a fixture that survives one failed LED and a fixture that loses the whole string. It is also the reason the minus 2 part exists: the improved status pin gives a cleaner indication of the same condition to whatever reads it.
E grade, and where 125 C junction comes from
The E part is guaranteed from 0 C to 125 C and the minus 40 C data is assured by characterisation. In a luminaire the ambient is usually the deciding factor rather than the cold end, and the arithmetic is the 43 C/W junction to ambient: at 85 C ambient a 125 C junction allows 40 C of rise, which is 0.93 W. The controller's own 1.7 mA at 40 V is 68 mW, and the gate charge of a 30 nC FET at 400 kHz is about 80 mW, so the package is comfortable. The number that is not comfortable is the FET's own dissipation, which is outside this part and inside the same enclosure.
The 7.15 V rail with its 34 mA current limit is also the ceiling on gate charge at high frequency. A 150 nC FET at 1 MHz needs 45 mA of average gate current, which the regulator cannot supply, so the gate drive collapses and the FET runs in its linear region. That is a failure that looks like a thermal problem and is actually a gate drive budget problem.
3000 to 1 dimming, measured at the right node
Dimming ratio is quoted on the current through the string, not on the PWM duty alone. At 200 Hz, 3000 to 1 is a 1.67 us pulse, and the 170 ns minimum off time is a tenth of it. Whether the current reaches its regulated value inside that pulse depends on the inductor and the switching frequency: at 400 kHz there are 4 switching periods in the pulse, at 1 MHz there are 1.7. Deep dimming at low frequency is therefore the only place the headline number is achieved, and the honest way to specify a fixture is a dimming curve at the actual frequency rather than the ratio on the first page.
The CTRL pin, which spans 0 to 1.1 V for analog dimming, is the other half of the story. Mixing analog and PWM dimming is how a 10000 to 1 range is built in practice: PWM for the bottom decade, analog for the top.
Buyers usually arrive at the power management cross reference to find the family alternatives, then use one stop BOM sourcing to confirm a substitute before it is fitted; component lead time solutions is the routine for a part that has already stopped shipping.
Two questions buyers ask
Is the E grade the right choice for an outdoor luminaire? If the fixture is specified to start below 0 C, no. The guarantee starts at 0 C and the cold data is characterised, not tested, so a specification that calls for minus 20 C or minus 40 C start needs the I or H grade. For an indoor fixture the E part is the cheaper correct answer.
What happens if the disconnect FET is left out? An open string drives the boost to its maximum output and the overvoltage protection pulls PWMOUT low, which protects the converter but not the string. The remaining LEDs see the full output voltage and usually fail in turn, so the FET is what turns a single failure into a reported single failure.