LT3652HVIMSE#TRPBF
Product Specifications
LT3652HVIMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3652HVIMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3652HVIMSE#TRPBF: 18 V Float From a 3.3 V Reference and the Divider That Sets the Error
The LT3652HV is a step-down charger for packs that are not one cell: it takes 4.95 V to 34 V in, 40 V absolute maximum, and programs any float voltage up to 18 V with a resistor divider from a 3.3 V internal reference. Charge current is up to 2 A from a 100 mV sense threshold, the input voltage regulation loop cuts charge current when the source sags below a set level, which is what makes it a peak power tracker on a solar panel, and termination is C/10 or the on board timer. This is the part behind four cell Li-Ion packs, five cell LiFePO4 packs and 12 V lead acid batteries charged from an unregulated adapter.
Published values
| Parameter | Value |
|---|---|
| Input range | 4.95 V to 34 V, 40 V absolute maximum |
| Float voltage | Programmable up to 18 V |
| Float reference | 3.3 V, 0.5 percent accuracy |
| Feedback pin bias current | 110 nA, 250 k equivalent resistance recommended |
| Charge current | Up to 2 A, 5 percent accuracy |
| C/10 termination | 10 mV sense, 2.5 percent accuracy |
| Input regulation loop | Cuts charge current below a set input voltage |
| Start-up requirement | Input 3.3 V above the programmed float |
| Minimum operating headroom | 0.75 V above float once switching |
| Switching frequency | 1 MHz fixed |
| Standby and shutdown | 85 uA and 15 uA |
| Parallel operation | Stated for higher output current |
| Packages | 12 pin 3 mm by 3 mm DFN and 12 pin MSOP |
18 V needs a ratio of 5.45, and two 1 percent resistors cost 450 mV
The divider sets float as 3.3 V multiplied by one plus the ratio of the two resistors, so 18 V needs a ratio of 4.4545 and a total gain of 5.4545. The 0.5 percent reference accuracy is only part of the error: two 1 percent resistors add their tolerance to it, and the worst case stack of 0.5 plus 1 plus 1 percent is 2.5 percent, which at 18 V is 450 mV. Move to 0.1 percent resistors and the stack is 0.7 percent, or 126 mV at the same float voltage. That difference is worth more than the price difference on most BOMs, because a 450 mV spread on a five cell LiFePO4 pack is the difference between a full pack and a pack that is 4 percent short for its whole service life. The 110 nA of bias current at the feedback pin is the other term: a 250 k equivalent resistance keeps its effect at about 27 uV, which is nothing, and a 1 M divider makes it something.
Start-up wants 3.3 V above the pack, which decides the adapter
An 18 V pack needs 21.3 V at the input to start charging reliably, and about 18.75 V to keep running once the loop is up. That single rule rules out a 19 V notebook adapter for an 18 V pack, and it makes a 24 V unregulated adapter the natural partner, which is exactly the application the vendor puts on the front page: a 24 V 1 A wall transformer charging a five cell LiFePO4 pack at 18 V and 1.5 A. The input regulation loop then earns its place, because an unregulated 24 V transformer sags as it loads, and the loop reduces charge current rather than letting the adapter collapse and restart the cycle.
Parallel operation and what it does not do
The data sheet states the part is parallelable for higher output current, which is how a 4 A charger is built out of two of them, each with its own sense resistor and its own float divider. Two things have to be true for that to work: both dividers have to be trimmed to the same float voltage within the 0.5 percent reference tolerance, and both input regulation loops have to be set to the same source voltage, otherwise one charger takes the whole load until the source sags and the other picks up what is left. Where a solar input has to feed a pack and a load at the same time, the power management cross reference lists the family alternatives, BOM shortage recovery is the route we take when an order code cannot be found, and the ADI second source page covers what else can do the same job.
Two questions buyers ask
Can it charge a four cell Li-Ion pack at 16.8 V? Yes, with a divider set for 16.8 V. The 18 V ceiling leaves room for the setting, and the 0.75 V minimum headroom means the source has to be at least 17.55 V while charging, so a 24 V adapter or an 18 V solar panel in full sun is the right class of source. A 19 V adapter sits close enough to the line that the input loop will spend its time cutting current.
Does the C/10 termination work at 18 V? It measures the sense voltage, not the pack voltage, so it terminates at one tenth of the programmed current whatever the float setting is. At a 2 A setting the C/10 point is 200 mA with 2.5 percent accuracy, that is 5 mA, and the 85 uA standby then holds the pack until it falls 2.5 percent, which at 18 V is 450 mV.