RF Fixed Attenuators and Terminations for Instrument Chains
Product Specifications
Product Overview
A fixed attenuator is a resistive pad in a coaxial body, and it is used for four different jobs in a radio or a test rack. It sets a level: a 10 dB pad in front of a spectrum analyser input moves the reference and protects the front end. It improves a match: a 3 dB pad on a port with a poor return loss cuts the reflection by 6 dB in each direction, which is often enough to stop an amplifier from oscillating. It extends a range: a 20 dB pad ahead of a power sensor brings a large signal into the linear part of the meter. And it isolates: a pad between two stages reduces the pull that the second stage puts on the first.
The electrical behaviour that matters is not the nominal value but the accuracy across the band, and the accuracy of a resistive pad is set by its construction. The BW-S series quad is quoted at plus or minus 0.40 dB for 1 dB to 6 dB values, plus or minus 0.60 dB for 8 dB and 10 dB, and minus 0.5 dB plus 0.8 dB or more for the 20 dB to 40 dB values, where the absolute error grows because the resistor ratio grows. That figure includes frequency and power variation over the band at 25 C, and a temperature coefficient of 0.0004 dB per dB per degree C applies on top of it.
VSWR is quoted by band because a coaxial pad cannot hold one figure across 18 GHz. The SMA 2 W family is 1.20 to 1 at DC to 4 GHz, 1.25 to 1 from 4 GHz to 8 GHz, 1.30 to 1 from 8 GHz to 12.4 GHz, and about 1.6 to 1 from 12.4 GHz to 18 GHz. The 12.4 GHz break is not arbitrary: it is the frequency where the connector and the body start to behave as a transmission line rather than a lumped element. A product that runs to 18 GHz should expect the top band to be the one that limits the match.
Power is the other limit, and it is an average figure with a derating curve. The SMA 2 W parts are rated 2 W average at 25 C, derated linearly to 0.5 W at 100 C, with a 125 W peak allowed for a 5 microsecond pulse at 100 Hz. A pad that is asked to absorb a continuous 2 W in a 60 C rack is already outside the curve, and a pad used to protect a receiver front end from a nearby transmitter has to be checked against both the average and the peak. The terminations follow the same logic with their own figures: 1 W for the SMA part and 2 W for the N type part, each with a stated derating.
The table below covers the parts we quote most often: the SMA 2 W attenuator family, and terminations in SMA and N type. Attenuation and accuracy, VSWR by band, average power, connector and temperature come from the maker data sheet for each model.
Key Specifications
| Parameter | SMA fixed attenuator, BW-S2W2 series | SMA termination, ANNE-50+ | N type termination, KARN-50-18+ |
|---|---|---|---|
| Function | Fixed attenuation in a 50 ohm line | Terminates an unused port at 50 ohm | Terminates an unused port at 50 ohm |
| Frequency range | DC to 18 GHz | DC to 18 GHz | DC to 18 GHz |
| Nominal value | 1 dB to 40 dB depending on model | 50 ohm | 50 ohm |
| Accuracy or return loss | Plus or minus 0.40 dB for 1 dB to 6 dB, wider for 20 dB to 40 dB | 30 dB minimum to 4 GHz, 21 dB minimum 12 GHz to 18 GHz | 33 dB to 2 GHz, 18 dB at 18 GHz |
| VSWR by band | 1.20 to 1 up to 4 GHz, 1.25 to 1 to 8 GHz, 1.30 to 1 to 12.4 GHz, about 1.6 to 1 to 18 GHz | Not applicable, quoted as return loss | Not applicable, quoted as return loss |
| Average power | 2 W at 25 C, derated to 0.5 W at 100 C | 1 W at 25 C, derated to 350 mW at 100 C | 2 W, derated 0.025 W per degree C above 70 C |
| Peak power | 125 W for a 5 microsecond pulse at 100 Hz | Not quoted | Not quoted |
| Connectors | SMA female to SMA male | SMA male | N type male |
| Temperature | -55 C to +100 C | -55 C to +100 C | Rated to the derating curve |
Included Models and Order Codes
The table lists the models we quote most often for level setting, protection and match improvement in test and radio chains. Attenuation and accuracy, VSWR, average power and connector come from the maker data sheet for that model. The plus suffix in these codes marks the RoHS compliant version of the same electrical part, so a quotation always states which suffix is being offered.
| Part Number | Function | Value | Range | Accuracy or return loss | Power | Connector |
|---|---|---|---|---|---|---|
| BW-S3W2+ | Fixed attenuator | 3 dB | DC to 18 GHz | Plus or minus 0.40 dB | 2 W average, 125 W peak | SMA female to SMA male |
| BW-S6W2+ | Fixed attenuator | 6 dB | DC to 18 GHz | Plus or minus 0.40 dB | 2 W average, 125 W peak | SMA female to SMA male |
| BW-S10W2+ | Fixed attenuator | 10 dB | DC to 18 GHz | Plus or minus 0.60 dB | 2 W average, 125 W peak | SMA female to SMA male |
| BW-S20W2+ | Fixed attenuator | 20 dB | DC to 18 GHz | Minus 0.5 dB, plus 0.8 dB | 2 W average, 125 W peak | SMA female to SMA male |
| BW-S30W2+ | Fixed attenuator | 30 dB | DC to 18 GHz | Plus or minus 0.85 dB | 2 W average, 125 W peak | SMA female to SMA male |
| BW-S40W2+ | Fixed attenuator | 40 dB | DC to 18 GHz | Minus 0.5 dB, plus 1.5 dB | 2 W average, 125 W peak | SMA female to SMA male |
| ANNE-50+ | Termination | 50 ohm | DC to 18 GHz | 30 dB return loss to 4 GHz | 1 W average | SMA male |
| KARN-50-18+ | Termination | 50 ohm | DC to 18 GHz | 33 dB return loss to 2 GHz | 2 W average | N type male |
Key Features
Accuracy quoted with the band – the plus or minus 0.40 dB figure covers 1 dB to 6 dB values including frequency and power variation, and the wider 20 dB to 40 dB tolerance is stated rather than hidden.
VSWR broken into bands – 1.20 to 1 below 4 GHz and about 1.6 to 1 at 18 GHz is what a coaxial pad actually does, and the quotation keeps the bands instead of quoting one number.
Power with a derating curve – 2 W at 25 C and 0.5 W at 100 C is the figure the thermal check needs, and the 125 W peak is quoted with its pulse width and duty cycle.
Stainless steel SMA bodies – the connector body and the coupling nut are stainless steel, which is what survives repeated mating in a test rack without the threads wearing.
Terminations matched to the pad family – the SMA and N type terminations use the same resistive construction, so a combiner port and an attenuator pad are quoted from the same level plan.
Small enough to leave in place – the SMA bodies are under 25 mm long, so a pad can stay on a port inside a chassis where a longer coupler would not fit.
Applications
These parts are quoted for radio and instrument chains where a level or a match has to be set, typically where:
Receiver and analyser front ends – a 10 dB or 20 dB pad ahead of a sensitive input brings a strong signal into range and gives the front end a better match at the same time.
Amplifier and mixer matching – a 3 dB or 6 dB pad on a port with a poor return loss cuts the reflection, which is often what stops a two stage amplifier from oscillating.
Test racks and production fixtures – terminations on unused combiner and switch ports keep the impedance at 50 ohm, so the measured level does not move when a channel is switched out.
The pads and terminations are fitted to the chassis ports and the test board of the same instrument, so they are quoted with the SUPERB PCB and the SUPERB PCBA build for that unit.
Sourcing and Cross-Reference
Selection starts with the level plan. The attenuation value is chosen so the following stage sits in its linear range at the highest signal it will see, and then the accuracy of that value over the band and over temperature decides whether the plan closes. A 1 dB pad with plus or minus 0.40 dB of error is a 40 percent uncertainty on the value, which is fine for protection and not fine for a calibrated level.
The second check is power and mating. Average power with the derating curve, peak power with its pulse width, and the number of mating cycles the connector will see in a fixture are all part of the choice. A pad that is correct electrically but rated 1 W in a 3 W point will drift and then fail open, and an N type termination used on an SMA port needs an adapter that adds its own mismatch.
Where a model is short or has been replaced, the substitute is checked on attenuation and accuracy, VSWR by band, average and peak power, connector type and body length at once. A part that matches the attenuation but not the connector will not mate, and a part that matches the connector but has a lower power rating will pass the bench test and fail in the rack. The route for that comparison is on our RF component sourcing page, and the cross reference check is on pin to pin cross reference.
For volume builds, SUPERB Assembly support covers the connector footprints, the torque specification at the chassis wall and the cable dress that keeps the pad from loading the connector.
Q: Can you quote the 10 dB and 20 dB SMA pads with the VSWR by band, and confirm the derated power at 60 C inside an enclosure?
A: Yes. Send the band, the level you have to set, the power at that point and the connector type, and the SUPERB Tech team will confirm the value, the accuracy and the derated power from the maker data sheet before quoting.
Why Buyers Source Attenuators Through SUPERB
- Accuracy and VSWR by band, not one number: the quotation keeps the per band figures, which is what a level plan and a link budget are actually calculated against.
- Derating curve carried into the quote: the 2 W rating comes with the 0.5 W at 100 C figure, so an enclosure temperature is checked before the part is ordered.
- Peak power with its pulse condition: the 125 W figure is quoted with 5 microseconds at 100 Hz, because a radar or a pulse application cannot use an average number alone.
- Connector and body length named: SMA or N type, male or female and the overall length are quoted with the part, which is what a chassis drawing and an adapter choice depend on.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Frequency converters and sources, Digital step attenuators, RF power dividers and couplers, RF isolators and circulators, RF gain blocks and LNAs, RF component sourcing, Component lead time solutions.