VBQG2610N
Product Specifications
VBQG2610N
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBQG2610N from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBQG2610N: a minus 60 V P channel in the 2 by 2 body
The VBQG2610N is the highest voltage P channel in this small family, printed at minus 60 V with 85 milliohm at a minus 10 V gate and 100 milliohm at minus 4.5 V, a minus 5 A case current and minus 4 A on the reduced drive column, 34 nC of gate charge and 1000 pF of input capacitance. The data sheet names high side switch for a full bridge converter and DC to DC converter for an LCD display. It is the part bought when a 48 V rail has to be switched in the positive line and a 30 V part has no margin.
Sixty volts covers a 48 V nominal rail with a 10 to 12 V overshoot and a clamp, and nothing more. A telecom 48 V rail in a battery plant can reach 58 V in equalise charge, which leaves 2 V of margin and no room for ringing, so the clamp and the snubber are part of the circuit rather than optional parts of it. The resistance of 85 milliohm at 10 V is high compared with the 30 V member of the family, and that is the tax on the voltage.
The threshold window is printed as minus 1 to minus 3 V, which is the highest in this band and the opposite of the minus 20 V parts at 0.4 to 2 V. A higher threshold is easier to keep off but harder to turn on with a low rail, and on a 48 V rail the drive is never the problem, so the higher threshold is a benefit rather than a cost here.
Key data for the VBQG2610N
| Configuration | Single P channel |
| Package | DFN 2 by 2 with exposed pad |
| VDS | Minus 60 V |
| Vth | Minus 1 to minus 3 V at 250 microamp |
| RDS(on) at minus 10 V | 85 milliohm |
| RDS(on) at minus 4.5 V | 100 milliohm |
| ID at a 25 C case | Minus 5 A |
| ID on the reduced drive column | Minus 4 A |
| Pulsed drain current | Minus 15 A |
| Avalanche current | Minus 22 A single pulse |
| Gate charge | 30 nC typical, 40 nC maximum |
| Ciss | 1000 pF |
| Applications | High side switch for a full bridge converter, DC to DC for an LCD display |
| Technology | Trench power MOSFET, halogen free, halogen free to IEC 61249-2-21 |
The gate charge of 30 nC typical against 40 nC maximum is a 33 per cent spread, and at 200 kHz that is 6 mA against 8 mA of drive current. In a full bridge where the high side gate has to be driven through a transformer or a charge pump, the 40 nC figure is the one that sizes the coupling capacitor and the pump, because the pump has to deliver that charge every cycle at the worst case temperature.
The avalanche rating of minus 22 A single pulse is the one number on this sheet that is easy to misread. It is a single pulse, and the sheet does not print the energy, so it cannot be turned into a margin against a 48 V line transient by arithmetic. What it does say is that the die is large enough to survive a pulse, and the clamp is still what defines the circuit.
Where a minus 60 V P channel is used
The first case is the high side of a full bridge in a DC to DC converter for an LCD backlight or a display bias rail. The P channel is the upper switch, driven by a bootstrapped or transformer coupled gate, and the 85 milliohm at 10 V sets the conduction loss at 0.85 W for a 1 A load. The full bridge is chosen because the rail is 48 V and the load is small, so the current is low and the loss is dominated by the resistance rather than by the switching.
The second case is a 48 V hot swap or a reverse polarity protection in the positive line of a telecom board. Here the part is on continuously and the 85 milliohm at 10 V is the steady state cost: 0.42 W at 2 A, which in a 2 by 2 body with a 28 to 30 K per watt path is a 12 to 25 C rise. That is acceptable, and a 30 V part is not, because 48 V plus ringing is over the limit.
The third case is a battery disconnect on a 48 V pack in a rack mount instrument. The part has to hold off the full pack voltage when the unit is off, and hold off the charger voltage when it is on, and both are within 58.8 V of a 14 cell pack. Sixty volts is the smallest class that covers that, and the margin is thin enough that the gate transient suppression is part of the circuit.
Drive, hold off and loss at 48 V
A P channel at 48 V needs the gate pulled 10 V below the source, which means a gate drive referenced to a 58 V rail. That is normally done with a zener and a resistor, or with a small N channel pulling the gate down through a resistor, and the 30 nC of gate charge is what the zener has to source on every turn on. A 10 k resistor from gate to source and a 12 V zener from gate to source is the standard arrangement: it holds the part off when the driver is absent and clamps the gate oxide at 12 V.
The resistance at minus 4.5 V, 100 milliohm, is 18 per cent above the 10 V figure, which is a small step compared with the 30 V parts in this family. That is a consequence of the higher threshold: the part is not near the knee at 4.5 V, so the channel is already well formed. It means a 5 V gate drive is usable at 48 V, which is useful when the drive comes from a logic level source rather than from the rail.
Where a 60 V part is being compared with the 100 V class for a 48 V rail, the strategic sourcing page covers how the codes are grouped and how a second source is kept qualified without carrying two full approvals. In practice the 60 V part is the one that fits with a clamp, and the 100 V part is bought when the transient is not bounded by the circuit.
What to check before this code is bought
The 60 V rating on a 48 V rail leaves 2 V of margin against the equalise voltage of a battery plant and nothing against ringing. That is a circuit fact, not a defect in the part, and it is the reason a 48 V P channel switch usually carries a transient suppressor and a gate source zener. A buyer who takes the 60 V label as a 60 V working voltage will see failures that look like part quality and are actually margin.
The sheet gives no energy figure for the avalanche rating, no safe operating area curve and no statement of the junction range in the rows we read. For a hot swap application the inrush energy has to be checked on the bench, and the gate slew is what controls it. A 10 k gate resistor with 1000 pF of input capacitance gives a turn on of a few milliseconds, which keeps an inrush into a 100 microfarad load well inside the pulse rating.
Where the code is bought in volume, the date code management page covers how lots are recorded and how a mixed reel is split before it reaches the line. On a 2 by 2 body the lot code is laser marked and hard to read, so the reel label is the record, and a distributor who splits a reel has to relabel it or the traceability is lost.
The gate charge spread of 30 to 40 nC also has a sourcing consequence. A second source that prints 30 nC maximum where this one prints 40 will change the pump sizing in a full bridge, so the comparison has to be made on the maximum column of both sheets rather than the typical one, which is where most substitutions go wrong.
Questions we get on this code
Is 60 V enough for a 48 V telecom rail? With a clamp and a snubber, yes. Against a 58.8 V equalise charge it leaves 1.2 V, and any ringing on top of that is over the rating. If the transient is not bounded by the circuit, the 100 V class is the honest choice.
Can it be driven from a 5 V logic output? Only with a level shift to the source rail. The threshold is minus 1 to minus 3 V, so a gate 5 V below a 48 V source turns it on, and the drive has to be referenced to the source, which a logic output is not.
Why is the resistance so much higher than the 30 V part in the same body? Because the drift region has to hold 60 V instead of 30 V, and that region is resistive. 85 against 22 milliohm is the price of the voltage class, and there is no way to buy both in a 2 by 2 body.
What happens if the gate is left floating? With a threshold of minus 1 to minus 3 V and a 48 V source, a floating gate can sit anywhere and the part can be partly on. A 10 k resistor from gate to source is not optional on this part.