VBQA3405
Product Specifications
VBQA3405
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBQA3405 from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBQA3405: a dual 40 V pair at 5.5 milliohm, sized for a set top box rather than a motor
The VBQA3405 is a dual N channel 40 V MOSFET in one leadless body, two channels with separate gate, drain and source pins. The summary prints 40 V, 5.5 milliohm at a 10 V gate, 6.5 milliohm at 4.5 V, 60 A continuous at a 25 C case and 20 nC of gate charge, and the application list on the sheet names set top boxes and low current DC to DC rather than the motor drives and synchronous rectifiers that usually appear on a 40 V part.
That application line is the honest description of the ratings. A 60 A channel would normally be paired with a dissipation row in the tens of watts and a junction to foot resistance of a few degrees per watt, while this sheet prints 2.7 W at a 25 C case and 38 C per watt from junction to foot. The part is a small dual switch for a low current rail, and the 60 A figure is a package limited row that the thermal path cannot support.
The two channels share one lead frame, so the temperature of one channel is the temperature of the other. In a half bridge that alternates, the two channels take turns dissipating and the shared path is not a problem. In a dual load switch where both channels conduct at once, the package dissipation has to be split between them, and the 2.7 W row becomes 1.35 W per channel.
The gate is symmetric at plus or minus 20 V with a threshold window of 1.0 V to 2.5 V and a 20 nC total gate charge at 10 V. The switching figures are asymmetric in an unusual way: at a 4.5 V drive the rise time is 55 ns while the fall time is 8 ns, and at a 10 V drive the rise time is 9 ns while the fall time is 6 ns. A part with a slow rise and a fast fall turns on softly and turns off hard, which suits a load switch and upsets a synchronous rectifier.
The parameter table in full
| Drain to source voltage | 40 V |
| Gate to source voltage, continuous | plus or minus 20 V |
| Continuous drain current, case at 25 C | 60 A, package limited |
| Continuous drain current, case at 70 C | 42 A |
| Continuous drain current, board at 25 C and 70 C | 50 A and 35 A |
| Pulsed drain current | 180 A |
| Continuous diode current, case at 25 C | 2.25 A in the ratings table, 60 A in the diode table |
| Single pulse avalanche current, 0.1 mH | 30 A |
| Single pulse avalanche energy | 55 mJ |
| Maximum power dissipation, case at 25 C | 2.7 W as printed |
| Maximum power dissipation, case at 70 C | 4.77 W as printed |
| Maximum power dissipation, board at 25 and 70 C | 2.78 and 1.14 W |
| Junction to ambient, 10 s, typical and maximum | 58 and 70 C per watt |
| Junction to ambient, steady state maximum | 110 C per watt |
| Junction to foot, typical and maximum | 38 and 45 C per watt |
| Breakdown voltage temperature coefficient | 32 mV per C |
| Gate threshold temperature coefficient | minus 5.0 mV per C |
| Gate threshold at 250 microamp | 1.0 V minimum, 2.5 V maximum |
| Gate leakage at 20 V | 100 nA maximum |
| Drain leakage at 20 V, 25 C and 55 C | 1 and 10 microamp |
| On state drain current at 10 V gate | 10 A minimum |
| On resistance at 10 V gate and 5 A | 0.0055 ohm typical |
| On resistance at 4.5 V gate and 4 A | 0.0065 ohm typical |
| Forward transconductance at 5 A | 16 S typical |
| Input, output and reverse transfer capacitance at 15 V | 1000, 217 and 155 pF |
| Total gate charge at 10 V and at 4.5 V | 15 and 6.7 nC typical |
| Gate source and gate drain charge | 4.4 and 3.05 nC typical |
| Gate resistance at 1 MHz | 0.8, 4.3 and 8.6 ohm |
| Turn on delay and rise time at 10 V drive | 4 and 9 ns typical |
| Turn off delay and fall time at 10 V drive | 10 and 6 ns typical |
| Turn on delay and rise time at 4.5 V drive | 12 and 55 ns typical |
| Body diode forward drop at 2 A | 0.8 V typical, 1.2 V maximum |
| Body diode recovery time | 11 ns typical, 20 maximum |
| Body diode recovery charge | 4 nC typical, 8 maximum |
| Reverse recovery fall and rise time | 7 and 4 ns |
| Operating junction and storage range | minus 55 to plus 150 C |
Two point seven watts at a 25 C case, and what that supports
The dissipation rows do not move the way they should. There is 2.7 W at a 25 C case and 4.77 W at a 70 C case, which says the part can shed more heat at a hotter case than at a cooler one. That cannot hold for one thermal path, and the two rows were evidently copied from different tables. The junction to foot row of 45 C per watt maximum is consistent with the 2.7 W figure, since 2.7 W times 45 is 121.5 C of rise from a 25 C foot, close to the 125 C difference between the 25 C case and a 150 C junction.
On a board the numbers are small. 70 C per watt for 10 s allows 1.79 W for a 125 C rise from a 25 C room, which through 5.5 milliohm is 18 A per channel at the cold figure and about 13 A at a doubled hot resistance. The steady state row of 110 C per watt allows 1.14 W and 14 A cold, 10 A hot. Those are the numbers a dual load switch actually has to live inside.
The 60 A continuous row and the 2.7 W dissipation row cannot both describe the same package. Sixty amps at 5.5 milliohm is 19.8 W, which through 45 C per watt is 891 C of rise, and even the case level path of 38 C per watt gives 752 C. The current row is a wire bond and lead frame limit, not a thermal limit, and a customer who needs 60 A has to look at a larger body.
The diode rows, the avalanche row and the two current tables
The diode current appears twice with values that are 27 times apart. The ratings table prints 2.25 A continuous source drain diode current at a 25 C case, and the diode characteristics table prints 60 A for the same condition. A dual 40 V part where the channel is 60 A and the diode is 2.25 A is plausible for a small body with a narrow diode, and 60 A of diode current on the same lead frame as a 2.7 W dissipation row is not. We treat 2.25 A as the real diode rating.
The avalanche test stores less than it claims. Energy is printed as 55 mJ against a 0.1 mH coil and a 30 A avalanche current, and half of 0.1 mH times 900 is 45 mJ. Here the printed energy is larger than the stored energy, which is the unsafe direction: a 55 mJ transient in a real clamp would put the die outside what the stated test demonstrates. For an inductive load we derate to the 45 mJ the test can actually deliver.
The gate resistance spread is wide for a dual part. 0.8 ohm minimum, 4.3 typical and 8.6 maximum is a ten to one window, and in a two channel package that spread decides which channel switches first. A half bridge built from one package is less exposed than two packages in parallel, but the turn on delay of 4 ns at 10 V drive against 12 ns at 4.5 V shows how much the drive level moves the edge.
Where a dual 40 V part earns its place
A set top box rail, a low current DC to DC post regulator, a dual load switch on a 12 V backplane and a polarity guard all fit inside the 1.8 W board allowance. The 20 nC gate charge and the 11 ns diode recovery make it easy to drive from a small controller, and the 4 nC recovery charge keeps the commutation loss negligible below 200 kHz.
It is the wrong part for a 40 A continuous load, for a motor drive that expects avalanche margin, and for a synchronous rectifier that relies on the body diode for a long interval, since 2.25 A of diode current will not survive a dead time at 20 A. A single channel part in a larger body is the answer in each case.
Our power management cross reference work records the diode current row and the junction to foot resistance per approved alternate for dual parts, because the two rows that differ by 27 times on this sheet are exactly the two that decide whether a substitute is safe in a synchronous position.
Questions we answer before a reel is booked
First, whether both channels run at once. The package allowance is 1.79 W on a board, and a dual switch that carries 10 A per channel at 5.5 milliohm is 1.1 W in total, which fits, while 18 A per channel is 3.6 W and does not. We ask for the simultaneous current rather than the per channel figure.
Second, the drive. A 1.0 V floor with a 4.5 V drive gives 55 ns of rise time, which is soft enough to limit inrush in a load switch and slow enough to lose efficiency in a converter. The 8.6 ohm maximum gate resistance plus an external resistor sets that edge, so the resistor has to be chosen against the maximum rather than the typical.
Third, the alternate. A dual 40 V part at 5 to 8 milliohm comes in the same body from several suppliers with diode ratings from 2 A to 60 A and avalanche energies from 20 to 100 mJ. We hold those rows per approved alternate, the incoming inspection plan checks the arriving lot against them, and the pin to pin comparison starts from the dual pad pattern and the pin order, since a dual part with the drains on opposite sides will not fit the same land.