VBP16R64SFD
Product Specifications
VBP16R64SFD
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBP16R64SFD from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBP16R64SFD: 600 V at 0.036 ohm and 64 A, with a diode that does not match the name
The VBP16R64SFD is a 600 V N channel super junction MOSFET in the TO-247 body, rated 64 A at a 25 C case and 39 A at 100 C, with 0.036 ohm at a 10 V gate measured at 21 A. The part number carries the FD suffix that the family uses for a fast body diode, and the recovery row on this sheet is 475 ns, which is five times the 90 ns of the 650 V members and not what a buyer expects from that suffix.
That mismatch is the reason to read this sheet row by row rather than by headline. The part is a strong switch: 0.036 ohm at 64 A is 147 W of conduction loss, and the 64 A row is the highest continuous current in the 600 V family here. For a continuous conduction power factor stage at 2 kW to 3 kW, or a hard switched forward converter at 100 kHz, it is the right device. For a bridge that relies on the body diode during dead time, it is not.
The applications list is the standard four: server and telecom supplies, switch mode supplies, power factor correction and lighting. The two that fit the diode on this sheet are the PFC stage and the forward converter, and the two that do not are any bridge and any resonant stage that lets the diode conduct.
The parameter table in full
| Drain source voltage at maximum junction temperature | 600 V |
| Gate source voltage | plus or minus 30 V |
| On resistance at 10 V gate and 21 A | 0.036 ohm typical |
| Gate threshold at 250 microamp | 2.5 V minimum, 4.5 V maximum |
| Gate source leakage at 20 V and at 30 V | plus or minus 100 nA and plus or minus 1 microamp |
| Drain leakage at 600 V, 25 C and 125 C | 1 microamp and 100 microamp |
| Forward transconductance at 21 A | 5.6 S typical |
| Input, output and reverse transfer capacitance | 6900, 80 and 4 pF |
| Effective output capacitance, energy and time related | 63 and 213 pF |
| Total gate charge at 10 V, 520 V and 8 A | 105 nC typical |
| Gate source and gate drain charge | 15 and 19 nC |
| Turn on delay and rise time at 520 V and 8 A | 18 and 24 ns typical, 25 and 55 maximum |
| Turn off delay and fall time, same conditions | 80 and 12 ns typical |
| Internal gate resistance at 1 MHz | 0.8 ohm |
| Continuous source drain diode current | 64 A |
| Pulsed diode forward current | 190 A |
| Diode forward voltage at 8 A | 1.5 V maximum |
| Reverse recovery time at 8 A and 400 V | 475 ns typical |
| Reverse recovery charge and peak current | 5.8 microcoulomb and 30 A |
| Single pulse avalanche energy, 28.2 mH and 7.5 A | 1600 mJ |
| Maximum power dissipation, case at 25 C | 230 W |
| Junction to case and junction to ambient | 0.57 and 62 C per watt |
| Continuous drain current at 25 C and 100 C case | 64 A and 39 A |
| Pulsed drain current | 190 A |
| Drain source and diode voltage slope | 50 and 15 V per ns |
| Operating junction and storage range | minus 55 to plus 150 C |
230 W on the page against 219 W through the thermal pair
The dissipation row prints 230 W at a 25 C case and the thermal table prints 0.57 C per watt. A 125 C rise through that path allows 219 W, so the printed figure is 11 W or 5 per cent above what the sheet itself supports. That is a small error compared with the 71 W and 81 W gaps on the 650 V sheets in this shipment, but it is the same kind of error and the thermal pair is the number to use.
In still air the ambient path allows 2.02 W, which through 0.036 ohm is 7.5 A at 25 C and 6.7 A at 50 C. The 64 A row sheds 147 W and needs the case at 98 C, which is a bolted heatsink. The 39 A row at a 100 C case sheds 54.8 W, which is 31 C of rise and leaves the junction at 131 C, and that is the row to use for a fan cooled supply.
The sheet prints no hot on resistance row. A super junction die of this area typically runs at 2.2 times the 25 C value at 150 C, so a 39 A load at the hot figure is 0.08 ohm and 122 W rather than 54.8 W. That is the difference between a circuit that works and one that cooks, and it is why we quote the case temperature rather than the current row.
The recovery row that contradicts the part number
475 ns of recovery with 5.8 microcoulomb and 30 A of peak reverse current at 8 A and 400 V is the same charge as the 650 V fast diode members but five times the time, which means the diode is a different die and the FD suffix on this part number is a family label rather than a measured property. The charge is what matters for the loss, so the part is usable in a PFC at 65 kHz, but a customer who reads the suffix and expects 90 ns will be disappointed.
Gate charge of 105 nC is the highest of the 600 V family after the 47 A part, which follows from the 6900 pF of input capacitance. At 100 kHz the drive power is 0.105 W, so the driver is not the limit; the 24 ns rise time is held by the 0.8 ohm internal gate resistance and the external resistor, and the 19 nC of gate drain charge is what sets the dv/dt.
The capacitance rows again print 80 pF of output capacitance and 63 and 213 pF of effective output capacitance, the same numbers as the 20 A and 41 A sheets, while the input capacitance is 6900 pF against 2300 pF. Four dies with a three to one ratio in input capacitance cannot share an output capacitance, so we treat those rows as a family template and measure the switching loss instead.
Where 0.036 ohm at 600 V is the right choice
A 2.5 kW continuous conduction power factor stage at 65 kHz, a 3 kW forward converter at 100 kHz, and a 1.5 kW server supply all use the 0.036 ohm well, because at 20 A the channel sheds 14.4 W and the heatsink is a normal one. The 64 A row is available for a surge or a short term overload, and the 39 A row at a 100 C case is the continuous figure in a fan cooled chassis.
Where it does not fit is a bridge or a synchronous rectifier above 100 V, because 475 ns of recovery at 400 V produces a reverse current spike that lands on the opposite switch. That is the same conclusion as the 47 A part in this family, and it is the one place where the FD label on this sheet is misleading enough to matter.
Our power management cross reference work files the recovery time and the recovery charge separately per approved alternate, because this sheet is the clearest example in the shipment of a part where the two disagree and only one of them describes the loss.
Questions we answer before a reel is booked
First, the avalanche row. 1600 mJ against a stated 28.2 mH and 7.5 A start is 793 mJ of stored energy, so the row is twice what its own test can produce. That is the largest such gap in the shipment and it puts this sheet in the same group as the 650 V parts, where we do not quote avalanche capability without the unclamped inductive switching report.
Second, the diode. The part is sold as a fast diode device and measures 475 ns, so a circuit that relies on the diode must be qualified on the bench rather than on the part number. We quote both the time and the charge, and we say which one sets the loss in the customer circuit, because 5.8 microcoulomb at 65 kHz is 0.38 W and 475 ns is not a loss figure at all.
Third, the alternate. A 600 V super junction part at 0.036 ohm is available from several suppliers whose recovery times run from 90 ns to over 500 ns at the same charge, so the label does not identify the die. We hold the measured recovery per approved alternate, the incoming inspection plan checks the lot against it, and the pin to pin comparison starts from the tab and the creepage distance rather than from the suffix.