VBP165R42SFD
Product Specifications
VBP165R42SFD
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBP165R42SFD from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBP165R42SFD: 650 V, 0.056 ohm and a 90 ns diode in the same body as its 41 A sibling
The VBP165R42SFD is a 650 V N channel super junction MOSFET with a fast body diode, in the TO-247 body, rated 42 A at a 25 C case and 0.056 ohm at a 10 V gate measured at 14 A. It shares a page structure, a thermal table and a diode test condition with the 41 A part in the same shipment, and the two differ by 0.006 ohm, one ampere of continuous rating and ten nanoseconds of recovery.
That small difference is exactly why the pair is worth a page of its own. A buyer choosing between them is not choosing between two technologies, and a substitution that keeps the footprint and the voltage but changes the part number will move the conduction loss by 10 per cent and the diode charge not at all. The choice is made on price, on availability and on the 4 A of difference in the continuous row, not on the data sheet headline.
The applications are the standard four for the class: server and telecom supplies, switch mode supplies, power factor correction, and lighting ballast. The duty in all four is the same, a switch working against a 380 V to 400 V rail with a surge on load release, and the 650 V rating is the margin over that rail.
The parameter table in full
| Drain source voltage at maximum junction temperature | 650 V |
| Gate source voltage | plus or minus 30 V |
| On resistance at 10 V gate and 14 A | 0.056 ohm typical |
| Gate threshold at 250 microamp | 2.5 V minimum, 4.5 V maximum |
| Gate source leakage at 20 V and at 30 V | plus or minus 100 nA and plus or minus 1 microamp |
| Drain leakage at 650 V, 25 C and 125 C | 1 microamp and 100 microamp |
| Forward transconductance at 14 A | 5.6 S typical |
| Input, output and reverse transfer capacitance | 4500, 80 and 4 pF |
| Effective output capacitance, energy and time related | 63 and 213 pF |
| Total gate charge at 10 V, 520 V and 8 A | 74 nC typical |
| Gate source and gate drain charge | 15 and 19 nC |
| Turn on delay and rise time at 520 V and 8 A | 18 and 24 ns typical, 25 and 55 maximum |
| Turn off delay and fall time, same conditions | 80 and 12 ns typical |
| Internal gate resistance at 1 MHz | 0.8 ohm |
| Continuous source drain diode current | 42 A |
| Pulsed diode forward current | 125 A |
| Diode forward voltage at 8 A | 1.5 V maximum |
| Reverse recovery time at 8 A and 400 V | 90 ns typical |
| Reverse recovery charge and peak current | 5.8 microcoulomb and 30 A |
| Single pulse avalanche energy, 28.2 mH and 8 A | 1460 mJ |
| Maximum power dissipation, case at 25 C | 300 W |
| Junction to case and junction to ambient | 0.57 and 62 C per watt |
| Continuous drain current at 25 C and 100 C case | 42 A and 26 A |
| Pulsed drain current | 125 A |
| Drain source and diode voltage slope | 50 and 15 V per ns |
| Operating junction and storage range | minus 55 to plus 150 C |
300 W on the page, 219 W through the thermal path
The dissipation row prints 300 W at a 25 C case and the thermal table prints 0.57 C per watt. 0.57 C per watt with a 125 C rise allows 219 W, so the dissipation row is 81 W above what the same sheet says the path can carry. The derating factor of 1.67 W per C is the 219 W figure spread over 125 C, so two of the three rows agree and the 300 W row is the odd one out.
In still air 62 C per watt allows 2.02 W, which through 0.056 ohm is 6.0 A at 25 C and 5.37 A at 50 C. The 42 A headline needs 98.8 W of channel loss and a case at 94 C, which is a bolted heatsink with a thermal interface and not a pad on a board. The number a customer should carry into a technical review is the case temperature at their loss, and the 42 A row is where the case temperature is already 25 C.
The 26 A row at a 100 C case is the more useful one in a real supply, because a 100 C case is reachable inside a sealed enclosure with a fan. 26 A through 0.056 ohm is 37.9 W, which is 21.6 C of rise through the 0.57 path, so the junction sits at 121 C and there is 29 C of margin left for a surge.
The diode, the gate charge and the difference from the 41 A part
Recovery is 90 ns with 5.8 microcoulomb and 30 A of peak reverse current at 8 A forward and 400 V. The 41 A sibling prints 80 ns from the same test with the same charge, so the ten nanoseconds are a rounding difference in the same die family and not a different diode. Both are fast enough for a continuous conduction PFC at 65 kHz and neither is soft enough for an unclamped phase node at 15 V per ns.
Gate charge is 74 nC at 10 V, 520 V and 8 A, against 68 nC on the 41 A part, and the split is 15 nC of gate source against 19 nC of gate drain. At 100 kHz the drive power is 0.074 W, so a 0.3 A driver has ample margin and the 24 ns rise time is set by the 0.8 ohm internal resistance and the external resistor rather than by the driver current.
The avalanche row prints 1460 mJ against a stated 28.2 mH and 8 A start, which stores 902 mJ, so the row is 62 per cent above its own test. Three 650 V sheets in this shipment share that error and one of them is the 41 A sibling, which suggests a family document rather than a measurement. The row is not usable for sizing a snubberless flyback.
Where 0.056 ohm changes the decision
A 3 kW server supply at 65 kHz, a telecom rectifier at 100 kHz, and a 2 kW continuous conduction PFC all gain about 10 per cent in conduction loss against the 41 A part, which is 1 to 4 W at full load and enough to matter in a sealed 1U chassis. The 42 A continuous row also buys one more ampere at a 100 C case, which is where a fan cooled supply actually runs.
Where the 0.056 ohm does not help is a light load efficiency target, because at 10 per cent load the loss is dominated by the output capacitance and the gate charge, and the two parts are within 6 nC of each other. A customer chasing a 94 per cent efficiency at 20 per cent load should look at the switching frequency and the driver, not at 0.006 ohm.
Our power management cross reference work keeps the recovery charge, the output capacitance and the thermal pair per approved alternate, because the 41 A and 42 A parts are close enough on paper that the choice has to be made on the measured diode and the price rather than on the summary page.
Questions we answer before a reel is booked
First, the gate. The threshold window of 2.5 V to 4.5 V rules out a 5 V logic driver, and the flat charge split of 15 nC against 19 nC means the Miller plateau is short but the current through it is high. Drive from 10 V, and size the external resistor from the 24 ns rise time and the 8 A test current rather than from a rule of thumb.
Second, the 300 W row. A customer who writes 300 W into a thermal budget will order a heatsink that runs the junction at 212 C in the first hour. We quote 219 W from the thermal pair and say why, and we ask for the case temperature the enclosure can hold before quoting a current at all.
Third, the alternate. A 650 V super junction part at 0.056 ohm with a fast diode comes from several suppliers with 5.8 to 28 microcoulomb of recovery charge, and the charge is what lands on the opposite switch. We hold it per approved alternate, the incoming inspection plan checks the lot against it, and the pin to pin comparison starts from the tab, the creepage and the gate resistor the board already has.