The VBMB18R11SE from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBMB18R11SE: 800 V and 11 A with 350 milliohm in a TO220F
The VBMB18R11SE is a single N channel MOSFET in a TO220F body rated at 800 V drain to source, plus or minus 30 V on the gate, a 3.5 V threshold, 11 A of drain current and 350 milliohm at a 10 V gate. The die is SJ deep trench rather than the multiple epitaxy structure used by most of this band, which is a different way of building the charge balance layer.
The suffix E in the code points at that structure and the practical difference is in the trade between resistance and recovery. A deep trench charge balance die typically has a lower output capacitance for the same resistance and a body diode with a different recovery shape, which matters in a bridge leg and matters little in a flyback.
Eleven amps at 350 milliohm is 42 W, at 6 A it is 12.6 W, at 4 A it is 5.6 W, at 2 A it is 1.4 W. As with every part in this body, the working current is set by the plastic tab and the sink, which puts the range at 2 to 6 A.
Key data for the VBMB18R11SE
| Configuration | Single N channel |
| Package | TO220F, isolated plastic tab |
| VDS | 800 V |
| VGS | Plus or minus 30 V |
| Vth | 3.5 V typical |
| ID | 11 A, a die figure at a 25 C case |
| RDS(on) at 10 V | 350 milliohm |
| Technology | SJ deep trench |
| Loss at 2 A | 1.4 W |
| Loss at 4 A | 5.6 W |
| Loss at 6 A | 12.6 W |
| Loss at 11 A | 42 W |
Deep trench against multiple epitaxy at 800 V
Both structures reach 800 V by shaping the electric field in a thick drift region, and they differ in how the charge balance columns are built. Multiple epitaxy grows and implants several layers, deep trench etches trenches and fills them. The trench process gives a tighter control of the column charge, which usually shows up as a lower resistance for the same breakdown voltage and a smaller spread from lot to lot.
The cost is a different body diode. A deep trench die at this voltage often has a sharper recovery than a multiple epitaxy die of the same class, which is good for switching speed and bad for ringing in a bridge leg. In a flyback or a power factor stage the diode conducts only in the dead time and the difference is small. In a half bridge it decides the snubber and the dead time.
For a buyer the difference is not visible in the table at all, because the table prints the same columns. It shows up in the ringing on the first prototype and in the recovery loss at the operating frequency, which is why a sample is worth more than a data sheet comparison when the topology has a bridge.
For a buyer the practical difference between the two structures is the lot spread. A trench process controls the column charge more tightly, so the breakdown voltage of one reel is close to the one tested on the bench, while a multiple epitaxy die can sit 20 to 30 V away from the nominal. At 800 V that spread is part of the margin, and it is the reason a part tested at 780 V on a sample is not a part that can be signed off on one measurement.
Margin, clamp and the 800 V ceiling
Eight hundred volts holds a 480 V AC line at 680 V with 120 V of margin, which is the normal rule for a clamped flyback, and it holds a 400 V bus with a large margin for regeneration. It does not hold a 690 V line whose peak reaches 975 V, and it does not hold a 600 V bus with a lightning surge of 300 V.
The clamp is what makes the margin real. In a flyback the leakage inductance stores energy that has to go somewhere at turn off, and the clamp voltage plus the reflected voltage plus the leakage spike is the drain voltage. A clamp set at 150 V above the reflected voltage with a fast diode keeps the peak predictable; a clamp set too high to save efficiency gives the margin away.
The other margin is thermal. A part run at 780 V survives the bench and fails on the first hot day because the breakdown voltage falls with temperature at about 0.1 per cent per degree for some structures. The 800 V figure is at 25 C, so the derating at 125 C has to be part of the calculation rather than an afterthought.
Where the part fits and where it does not
It fits a flyback on a 480 V AC line below 100 W, a power factor stage on a 277 V line, an auxiliary supply in a 690 V drive, a start up circuit and a high voltage load switch at a few amps. It does not fit a 690 V line without a 1200 V device, a 20 A load, or a bridge leg without a snubber and a careful dead time.
Where the part is bought as a second source for an existing 800 V code, the structure matters as much as the table, because a deep trench die and a multiple epitaxy die with the same resistance can behave differently in a bridge. Our power management cross reference page covers how the two are put side by side before a sample is approved.
The sourcing side of this part is covered on the incoming inspection plan. For a part whose structure is not visible in the table, that page covers what is checked on arrival.
Questions we get on this code
What does the E in the code mean? It marks the deep trench structure in this family. The electrical table is the same shape as the multiple epitaxy parts and the recovery behaviour is not.
Is 11 A usable? No. Forty two watts has no path out of a plastic tab. Two to six amps with a sink is the working range.
Can it be used in a half bridge? Yes with a snubber and a dead time set for the sharper recovery. In a flyback the difference from the other structure is small.
What does the order carry? Part number, TO220F, tube packing and the date code. We confirm both on the offer.