Contact Us

VBMB17R18S

Brand: VBsemi
VBsemi VBMB17R18S is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBMB17R18S — Discrete & Power Semiconductors | Superb Automation

VBMB17R18S

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBMB17R18S from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBMB17R18S: 700 V and 18 A with 260 milliohm in a TO220F

The VBMB17R18S is a single N channel MOSFET in a TO220F body rated at 700 V drain to source, plus or minus 30 V on the gate, a 3.5 V threshold, 18 A of drain current and 260 milliohm at a 10 V gate. The die is SJ multiple epitaxy. Seven hundred volts is an unusual class and it exists for one reason: a 480 V AC line at 680 V after rectification leaves 20 V of margin at 700 V, which is thin but legal in a circuit with a good clamp.

The more common use is a 400 V bus in a product that sees a high surge, or a flyback on a 277 V single phase line in a lighting product. In both cases a 650 V part would be cheaper and a 800 V part would be safer, and 700 V is the compromise that fits the clamp the circuit can afford.

Two hundred and sixty milliohm at 18 A is 84 W, at 8 A it is 16.6 W, at 5 A it is 6.5 W, at 3 A it is 2.3 W. In a plastic tab with a small heatsink the working range is 3 to 6 A, and on a copper island it is 2 to 4 A.

Key data for the VBMB17R18S

ConfigurationSingle N channel
PackageTO220F, isolated plastic tab
VDS700 V
VGSPlus or minus 30 V
Vth3.5 V typical
ID18 A, a die figure at a 25 C case
RDS(on) at 10 V260 milliohm
TechnologySJ multiple epitaxy
Loss at 3 A2.3 W
Loss at 5 A6.5 W
Loss at 8 A16.6 W
Loss at 18 A84 W

Choosing 700 V instead of 650 or 800

The voltage class is set by the worst case drain voltage, and the worst case rarely appears on the bench. A 400 V bus with a motor that regenerates can reach 450 V, a flyback clamp can let the drain reach 550 V, and a lightning surge on a 230 V line can add 300 V for a few microseconds. The sum is what the part has to hold, and the class is chosen with 15 to 20 per cent above that sum.

Seven hundred volts buys 50 V over a 650 V part for a modest increase in resistance, since 650 V parts of the same die area print about 220 milliohm. It gives up 100 V to an 800 V part, which prints about 350 milliohm at the same area. The middle class exists for a circuit where the clamp is good but the margin with 650 V is not comfortable.

Where the clamp is a simple RC across the primary, the drain can ring above the clamp voltage for a few cycles, and the peak depends on the leakage inductance and the diode recovery. That is the case where the extra 50 V earns its price, and where a 650 V part with the same circuit would fail in the field rather than on the bench.

Loss, thermal and the switching term

At 5 A the conduction loss is 6.5 W. A TO220F on a 2 C per watt heatsink lifts the junction 13 C above the sink, so a 75 C sink leaves the die at 88 C, which is acceptable. At 8 A the loss is 16.6 W and the same sink lifts the die 33 C, which needs a sink below 60 C and probably a fan.

Switching loss at 700 V is not small. The energy in the output capacitance is lost at every turn on in a discontinuous converter, and at 100 kHz with a 700 V swing it can reach 0.5 to 1 W even at 2 A. That term is why a part of this class is usually run below 100 kHz, and why a soft switching topology changes the arithmetic in its favour.

The body diode recovery is the third term. At 700 V the diode is fast, and in a continuous mode converter its recovery charge is dumped into the opposite switch at every commutation. A snubber or a soft recovery diode in parallel reduces it, and the loop inductance decides how much of it becomes a voltage spike rather than a loss.

Where the part fits and where it does not

It fits a flyback on a 277 V line, a 400 V bus with a regeneration event, a power factor stage below 200 W, an auxiliary supply in a 480 V drive and a discharge path on a high rail. It does not fit a 480 V AC line without a clamp, a 20 A load, or a 200 kHz converter at more than 2 A.

Because the class sits between two common ones, this part is often the answer when a 650 V code has failed a surge test and an 800 V code will not fit the loss budget, and the check is on the clamp rather than on the table. Our obsolete part cross reference hub page covers how such a middle class replacement is selected when the original is no longer available.

The sourcing side of this part is covered on the component lead time solutions. For a middle voltage class that few lines carry, that page covers how the supply is planned around the lead time.

Questions we get on this code

Is 700 V enough for a 480 V AC line? At 680 V after rectification it is 20 V of margin, which is only safe with a clamp and a verified surge test. Most products use 800 V or more.

Can it replace a 650 V part? Yes where the clamp allows the extra 50 V and the loss budget allows 260 milliohm against 220. The footprint is the same in TO220F.

Is a heatsink needed? Above 3 W yes. The plastic tab makes the path worse than a metal tab, so the sink has to be sized for 2 to 3 C per watt.

What does the order carry? Part number, TO220F, tube packing and the date code. We confirm both on the offer.