HXC50109
Product Specifications
HXC50109
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXC50109 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXC50109: 260 W on a 50 V rail and the 0.5 degree per watt that makes it workable
The HXC50109 is a Hisiwell LDMOS RF power transistor filed on the HF to 1.0 GHz line with a 130 W row per device and two devices in a pair, which is the 260 W the vendor page states as the headline. It runs on 50 V and it carries the CW Enhanced label on the index, a label the site does not define anywhere. The row publishes no gain and no efficiency, so a buyer choosing between this part and its neighbours has to go one level down to the document, and that document is where the useful numbers are.
What separates this row from the rest of the shelf is not the 260 W. It is the thermal resistance of 0.5 degrees per watt, published in the vendor document. On a 260 W part running at 60 per cent drain efficiency there are 173 W of heat to move, and 0.5 degrees per watt turns that into an 87 degree rise. At an 85 degree case temperature the junction sits near 172 degrees against a 225 degree maximum. That is margin, but it is margin an engineer can count, and on this shelf it is rare: most rows publish no thermal figure at all and the buyer has to ask.
Three things about this row need to be said before any number is quoted. The first is that the document attached to the page is titled HX510260VP, not HXC50109. The numbers inside match the row, 260 W, 50 V, HF to 1.0 GHz, so the two names very probably describe one die, but no statement from the vendor says so. The second is that the index calls the mode CW while the document measures the functional row with a pulsed CW signal at 915 MHz. The third is that the label CW Enhanced appears on this row and on one other row on the same shelf, and nowhere on the site is it explained. Treat it as a vendor grade marker and ask what it changes before you commit a build.
The HXC50109 rows as the vendor publishes them
| Part class | LDMOS RF power transistor, unmatched, two devices in a pair |
| Frequency range, index row | HF to 1.0 GHz |
| Frequency range, vendor page | HF to 1.0 GHz, broadband fixture 30 to 1000 MHz |
| Output, index row | 130 W per device, 260 W for the pair |
| Output in dBm, calculated | 51.14 dBm per device, 54.15 dBm for the pair |
| Drain rail, all sources | 50 V nominal, 55 V maximum operating |
| Drain to source breakdown, document | 105 V minimum, 110 V typical |
| Gate to source maximum, document | minus 10 V to plus 10 V |
| Junction temperature maximum, document | 225 degrees C |
| Case operating temperature, document | 150 degrees C |
| Thermal resistance, junction to case, document | 0.5 degrees C per watt, DC test at 25 degree case |
| Power gain at 260 W, document | 19 dB typical, measured at 915 MHz |
| Drain efficiency at 260 W, document | 60 per cent typical |
| Input return loss, document | minus 7 dB typical |
| Ruggedness, document | 10 to 1 VSWR at all phase angles |
| Gate threshold voltage, document | 2.73 V typical at 600 microamps |
| Gate quiescent voltage, document | 3.16 V at 100 mA drain current, 50 V rail |
| On state resistance, document | 900 milliohms, each half of the device measured |
| Input capacitance, document | 85 pF at 50 V, 1 MHz, per half |
| Output capacitance, document | 36 pF at 50 V, 1 MHz, per half |
| Feedback capacitance, document | 1.2 pF at 50 V, 1 MHz, per half |
| ESD class, document | Human body model Class 2 |
| Package, document | Eared flanged ceramic, two mounting holes, four leads, PKG-B4E |
| Fixture material, document | Rogers 4350B, 30 mil, board file on request |
| Measured output range, 30 to 1000 MHz | 225 W to 363 W saturated |
| Measured efficiency range, same table | 44.3 to 59.6 per cent |
| Measured gain range, same table | 13.65 to 19.15 dB |
| Orderable addendum | None published |
| Moisture level and packing quantity | Not published |
What 260 W into 50 ohm asks of the load, the rail and the output network
260 W into 50 ohm is 114.0 V rms and 161.2 V peak. Against a 50 V rail that is 3.22 times the supply, which sounds impossible until the topology is taken into account: this is a pair, each device drives its own half of the load line, and the drain of each device swings to roughly twice the rail at full power. The 110 V breakdown rating is the number that limits the drain excursion, and it is the reason a 50 V part is sold as a pair rather than as a single ended device at this power.
The load side is where the mechanical budget goes. At a 2 to 1 mismatch the voltage across the load reaches 322 V peak and at 3 to 1 it reaches 484 V. The vendor rates the device to 10 to 1 at all phase angles, which is the ruggedness claim buyers pay for in a broadcast or an industrial heating amplifier, but ruggedness of the die is not ruggedness of the output network. The capacitors in the matching section, the balun and the connector all see those peaks. On a 260 W row the usual failure is not the transistor, it is a 500 V capacitor chosen on the strength of a 50 V rail.
The supply has to deliver more than the RF. At 60 per cent efficiency the DC input is 433 W, which is 8.67 A at 50 V, and at 55 per cent it is 473 W and 9.45 A. A 50 V bus that holds its voltage at 8.7 A is a different proposition from a bench supply with a long lead: at 260 W the current step on key down is large enough that the lead inductance and the bus capacitance decide whether the part survives the first pulse. Put the bulk capacitance at the device flange, not at the far end of the harness.
The thermal path is the reason to pick this row over its neighbours
At 60 per cent efficiency the heat to remove is 173 W. With the published 0.5 degrees per watt the rise from case to junction is 87 degrees, which at an 85 degree case puts the junction at 172 degrees, 53 degrees below the 225 degree limit. Move the case to 100 degrees and the junction is at 187 degrees, still inside the limit but with less room for a hot day or a fan failure.
The document also prints a broadband table that shows how much the heat moves with frequency. At 100 MHz the part delivers 363 W at 59.6 per cent, which is 609 W of DC input and 12.18 A, and 246 W of heat. That is 123 degrees of rise, and at an 85 degree case the junction is at 208 degrees. Seventeen degrees of margin is what the sweet spot of the band actually offers, and it is the number to use when someone asks whether the part can run continuously at the low end of its range.
At the top of the band the picture inverts. At 1 GHz the part delivers 225 W at 49.3 per cent, so the DC input is 456 W and the heat is 231 W, nearly as much heat as at 100 MHz for 138 W less output. A single heat sink sized on the 260 W headline will be undersized at the top of the band and oversized in the middle. Size it on the worst case in the table, not on the nominal row.
Drive, gain and the 3.5 dB the band costs
At 19 dB of gain and 260 W of output the drive needed is 3.27 W, or 35.15 dBm. That is a comfortable number for a driver stage and it is why this row is often chosen over a high gain part with a narrower band. The broadband table tells a different story at the edges: gain falls to 15.65 dB at 30 MHz and 13.65 dB at 900 MHz, so the drive at 900 MHz is 10.5 W, more than three times the drive at the nominal point. The driver has to be specified on the worst case gain, not on the 19 dB headline, or the top of the band will be 5 dB short.
The same table shows 2.08 dB of saturated output spread between 225 W and 363 W, and 15.3 points of efficiency spread. A system that needs a flat 200 W across the band is inside the capability, since the weakest measured point is 0.51 dB above 200 W, but a system that needs a flat 260 W across the band is not, because 260 W is a nominal figure that the part reaches in the middle and exceeds at the bottom. Quote the band requirement and the frequency of measurement with the power, every time.
The input match is worth a note. The document gives a typical input return loss of minus 7 dB, which is a return loss a driver can live with but not a match that can be ignored. The S11 trace in the document wanders between minus 2.9 dB and minus 18.4 dB across the band, so the driver sees a load that changes with frequency. An isolator or a pad in front of the pair costs output but buys stability, and on a 19 dB part with a 10 to 1 ruggedness rating the pad is usually the cheaper decision.
Where the HXC50109 sits on the 50 V shelf
Above it in power on the same 50 V rail are the 400 W pair at HF to 1 GHz and the 500 W pair at HF to 500 MHz, which gives 1.87 dB and 2.84 dB more output for the same supply. Below it are the 200, 170, 140, 100 and 80 W single ended rows at HF to 1 GHz, each about 1 to 1.5 dB apart, so the shelf is built as a ladder in roughly 1 dB steps and a system requirement lands on one rung or the next, never in between.
Read as a choice, this row is the one to take when the requirement is a pair at 260 W with a broadband fixture, a published thermal resistance and a 10 to 1 ruggedness figure, and when the band is HF to 1 GHz rather than a single narrow channel. A buyer who needs one device rather than a pair takes the 140 W single ended row; a buyer who needs more than 300 W takes the 400 W pair and lives with the higher current. The full ladder, with drive and heat at each rung, is on the RF power transistor cross reference page.
Two procurement points follow from the gaps in the documentation. The first is that no orderable addendum is published for this row, so the reel or tray quantity, the moisture level and the marking have to come from the vendor in writing before a production order is placed. The second is that the document title differs from the catalogue number, which matters at goods inwards: a receiving clerk who checks the label against the purchase order will see two names for one part and will hold the shipment. The inspection route that handles that case without stopping the line is set out on the incoming inspection plan page, and the sourcing side of the same question sits on the RF component sourcing page.
Questions buyers ask about the HXC50109
Can the pair run from a 40 V supply instead of 50 V?
The document answers this directly: at 40 V the part still delivers more than 150 W CW across the 30 to 1000 MHz band, with more thermal margin than at 50 V. That is a useful escape route for a system with a 40 or 42 V bus, and it costs 2.4 dB of output against the 260 W rating. The current rises for the same power, since the rail is lower, so the supply and the drain choke have to be checked at the new operating point rather than assumed.
If the index says 130 W, why does the page say 260 W?
Because the index counts one device and the page counts the pair. The row is 130 W per device with two devices in the part, and 130 W plus 130 W is 260 W, which is 3.01 dB more. The document then prints 260 W as its output row, so a buyer reading only the index will think the part is half the size it is, and a buyer reading only the page will not know that each half is a separate drain that needs its own decoupling.
What does the CW Enhanced label change?
Nothing is published about it. The label appears on this row and on one other row of the same shelf, and the site does not define it, so it cannot be used as a specification. Ask the vendor what it means in terms of continuous output, junction temperature or screening, and get the answer in writing before it is quoted to a customer.