Contact Us

VBA5101M

Brand: VBsemi
VBsemi VBA5101M is a discrete semiconductors component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBA5101M — Discrete & Power Semiconductors | Superb Automation

VBA5101M

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBA5101M from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi (微碧半导体) specializes in discrete MOSFETs, power transistors, and protection devices for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBA5101M: a 100 V N and P pair in one SOP8

The VBA5101M is a complementary pair, one N channel and one P channel, in an SOP8 body rated at plus or minus 100 V, with a plus or minus 20 V gate window, thresholds of plus or minus 2 V, currents of 4.6 A on the N side and minus 3.4 A on the P side, and resistances of 100 and 165 milliohm at 4.5 V falling to 80 and 150 milliohm at 10 V.

A complementary pair is a push pull stage in one package, and 100 V is a high rating for that function. The usual use is a small half bridge or a level shifting output stage where one device sources and the other sinks, and where the two have to be matched closely enough that the crossover behaves.

The asymmetry between the two sides is the first thing to read. The N channel is 80 milliohm at 10 V and the P channel 150, which is the usual factor of nearly two between electron and hole conduction in the same body. The current ratings follow, 4.6 A against 3.4 A, and so does the loss for a given current.

Key data for the VBA5101M

ConfigurationDual, one N channel and one P channel
PackageSOP8, surface mount, 1.27 mm pitch
VDSPlus or minus 100 V
VGSPlus or minus 20 V
VthPlus or minus 2 V
ID, N channel4.6 A
ID, P channelMinus 3.4 A
RDS(on), N, 4.5 V and 10 V100 and 80 milliohm
RDS(on), P, 4.5 V and 10 V165 and 150 milliohm
TechnologyTrench
Gate chargeNot published on the catalogue page
Thermal pathEight leads, shared frame
Body diodesOne per device, opposite polarity, which is what makes the pair a push pull

One hundred volts in an SOP8

An SOP8 body with a 100 V rating is a creepage and clearance question before it is an electrical one. The lead pitch is 1.27 mm and the package has no exposed pad, so the 100 V appears across a moulding compound and an air gap of a fraction of a millimetre at the pins. For a product that has to pass a pollution degree 2 clearance requirement, that is worth checking rather than assuming.

The electrical side is straightforward: a 100 V trench die has a thicker drift region than a 60 V die, so the resistance per unit area is higher and the die is larger for the same resistance. The 80 milliohm N channel and the 150 milliohm P channel are consistent with that.

The pair is not matched in resistance and is matched in voltage. That is normal for a complementary pair, because the two dies are built for different conduction types rather than for symmetry, and a push pull stage is usually arranged so that the load current is set by the N side in one direction and the P side in the other with different on times.

Push pull, crossover and the gate drive

Driving a complementary pair from one signal is the reason to buy it. The gates can be tied together in some circuits, with the result that one device is on when the other is off, and the pair behaves as a single ended output stage. That arrangement has a shoot through risk only if the thresholds are badly mismatched, and a plus or minus 2 V pair with a common gate node turns both devices partly on around the midpoint, which is a real loss.

The cleaner arrangement drives the gates separately and sets a dead time. That needs two signals and a driver, which removes most of the simplicity, and at that point the pair is being used for its matching rather than its convenience.

For a 100 V push pull stage the crossover loss at a few hundred kilohertz is the dominant term, and it depends on gate charge, which the catalogue page does not publish. A first prototype has to measure it.

At 100 V the space between pins becomes part of the electrical specification. A conformal coating raises the effective clearance, but it also traps heat and has to be qualified for the voltage, and a coating that is not fully cured can leak at 100 V in a humid enclosure. The practical rule for a body of this size is to keep the drain and gate traces on opposite sides of the package where the routing allows, and to leave the pin adjacent to the high voltage node without a via or a test point close to it.

Where it fits

It fits a high voltage level shifter, a small push pull output stage on a 48 V or 72 V rail, a piezoelectric or electrostatic transducer driver, and a complementary output where one package is worth more than two placements. It does not fit a bridge with significant current, and it does not fit a product where the creepage between adjacent pins at 100 V is a certification question that has not been answered.

Our one stop BOM sourcing page covers how a group of parts is bought together, which is how a complementary pair should be handled, since the two sides have to come from the same lot to be matched.

The sourcing side of this part is covered on the kitting service. For a complementary pair that has to come from one lot, that page covers how the two sides are kept together.

Questions we get on this code

Are the two gates separate pins? The catalogue does not publish the pin map. A pair driven from one signal needs the gates tied internally, and only the data sheet says whether they are.

Can the P side carry 4.6 A too? No, the P figure is minus 3.4 A and the resistance is nearly twice the N side, so the loss at the same current is nearly twice as high.

Is 100 V enough for a 72 V pack? A charged 72 V pack is 84 V, so the margin is 16 V. It is workable with a clamp and not workable without one.

Does the pair need a dead time? If the gates are driven separately, yes. A common gate node relies on the thresholds and dissipates heavily around the midpoint.