Thyristors and SCRs for AC Power Control
Product Specifications
Product Overview
A thyristor latches on. Once the gate current passes the trigger threshold and the anode current passes the holding current, the gate loses control and the device stays on until the anode current falls below the holding level at the next zero crossing. That single behaviour is why an SCR is the cheapest way to switch an AC load: one small gate pulse per half cycle, no drive supply to keep alive, and the load current itself holds the device on.
The choice inside the family is made on three numbers. The first is blocking voltage, which has to cover the peak of the AC line plus the margin the application keeps for transients, so a 230 V AC line wants 600 V parts rather than 400 V parts. The second is the on state current at the case temperature the heatsink can hold, quoted as RMS current for a 180 degree conduction angle. The third is gate trigger current, and that one decides the driver: a 200 uA sensitive gate part runs from a logic pin through a resistor, while a 30 mA part needs a buffer or a pulse transformer.
Sensitive gate parts are not free. The same thin gate layer that makes 200 uA enough also makes the device easier to trigger by noise and by a fast rise of anode voltage, so the data sheet quotes a lower dv/dt figure and the gate needs a resistor to cathode plus a short twisted pair to the driver. Where the load is inductive and the board sits next to a contactor, the standard gate part with 15 mA to 30 mA trigger current is the more forgiving choice.
The table below covers the three groups we quote most often: 0.8 A sensitive gate parts in TO-92 for crowbar and interrupter circuits, 4 A to 12 A phase control parts in TO-225 and TO-220 for heaters and motor speed control, and the 25 A TO-220 family for inverters and high inrush loads. Trigger current, holding current, surge current and junction temperature are taken from the maker data sheet for each order code.
Key Specifications
| Parameter | Sensitive gate, TO-92 | Phase control, TO-225 / TO-220 | High current, TO-220AB |
|---|---|---|---|
| On state RMS current | 0.8 A | 4 A to 12 A | 25 A |
| Average on state current | 0.5 A | 2.55 A to 8 A | 16 A |
| Repetitive peak off state voltage | 400 V to 600 V | 500 V to 600 V | 400 V, 600 V, 800 V |
| Gate trigger current, max | 200 uA | 200 uA to 15 mA | 30 mA |
| Gate trigger voltage, max | 0.8 V | 0.8 V to 1.5 V | 1.5 V |
| Surge current, one half cycle | 7 A to 8 A | 20 A to 145 A | 250 A at 60 Hz |
| Holding current, max | 5 mA | 3 mA to 40 mA | 40 mA |
| Critical dv/dt, min | 75 V/us | 8 V/us to 200 V/us | 50 V/us |
| Junction temperature | -40 C to +125 C | -40 C to +110 C, -40 C to +125 C | -40 C to +125 C |
| Package | TO-92 | TO-225AA, TO-220AB | TO-220AB |
Included Models and Order Codes
The table lists the order codes we quote most often for phase control and crowbar duty. Voltage class, RMS current, trigger current, surge rating and package come from the maker data sheet for that code. The voltage class is part of the order code in most families, so a 600 V part and an 800 V part of the same series are different numbers and are never interchanged on a quotation.
| Part Number | VDRM / VRRM | IT(RMS) | IGT max | VGT max | ITSM | Package |
|---|---|---|---|---|---|---|
| P0102DA | 400 V | 0.8 A | 200 uA | 0.8 V | 8 A at 8.3 ms | TO-92 |
| C106MG | 600 V | 4 A | 200 uA | 0.8 V | 20 A | TO-225AA |
| BT151-500R | 500 V | 12 A | 15 mA | 1.5 V | 132 A at 8.3 ms | SOT78 (TO-220) |
| TYN612RG | 600 V | 12 A | 15 mA | 1.3 V | 145 A at 8.3 ms | TO-220AB |
| 2N6507G | 400 V | 25 A | 30 mA | 1.5 V | 250 A | TO-220AB |
| 2N6508G | 600 V | 25 A | 30 mA | 1.5 V | 250 A | TO-220AB |
| 2N6509G | 800 V | 25 A | 30 mA | 1.5 V | 250 A | TO-220AB |
Key Features
Trigger current decides the driver – a 200 uA sensitive gate part is driven from a logic output through a series resistor, while a 15 mA to 30 mA standard gate part needs a buffer, a pulse transformer or a driver IC, and that choice is made before the part number is fixed.
Surge rating covers the inrush – a 25 A part carries 250 A for one half cycle at 60 Hz and 300 A for 8.3 ms, which is the figure that matters when the load is a transformer, a motor or a capacitor bank rather than a resistive heater.
Holding current sets the latch – a 5 mA holding current lets a small load stay on once triggered, and a 40 mA holding current needs a load that draws more than that at the zero crossing, otherwise the device drops out every half cycle.
Voltage class read from the code – the 2N6504 to 2N6509 family covers 50 V to 800 V in the same TO-220 outline, so the last two digits of the code carry the blocking voltage and a substitution across classes is a change of part, not a change of grade.
Gate and cathode protection built in – a resistor from gate to cathode, a series gate resistor and a snubber across the device are quoted with the part when the load is inductive, because the dv/dt limit of a sensitive gate part is reached quickly by a switching contactor.
Thermal path stated with the part – junction to case resistance is 1.5 C/W on the 25 A TO-220 family and 3.0 C/W on the 4 A TO-225 part, so the heatsink is sized from the RMS current and the case temperature rather than from the headline rating.
Applications
These parts are quoted for boards and modules that switch an AC or high current DC load, typically where:
Heating and motor speed control – a 12 A phase control part in TO-220 sets the conduction angle of a resistive heater or a universal motor, and the trigger is synchronised to the zero crossing of the line by the controller.
Overvoltage crowbar and surge limiting – an 0.8 A sensitive gate part fires a fuse or a larger thyristor when the rail passes a set level, which is faster than a relay and needs only a few hundred microamps of gate current.
Inrush limiting and soft start – a 25 A part bypasses a series resistor after the bulk capacitors have charged, so the input rectifier sees a limited current at switch on and the resistor is shorted out of the path once the rail is up.
The thyristor sits in the power stage of the same assembly, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.
Sourcing and Cross-Reference
Selection starts from the load, not from the current rating. The peak repetitive voltage is set by the line plus the transient margin, the RMS current is set by the case temperature the heatsink can hold, and the gate current is set by the driver that already exists on the board. A part that is larger than needed costs heatsink area and gate drive, and a part that is smaller fails on the first inrush.
The second check is the gate circuit. A sensitive gate part needs a resistor from gate to cathode to hold off noise, a capacitor is not recommended there, and the gate lead has to be short. A standard gate part tolerates a longer lead and a pulse transformer, which is why it survives in boards that switch a contactor nearby.
Where a specific code has been discontinued, the substitution is checked on four figures at once: blocking voltage, RMS current, trigger current and package. Two parts in the same family often differ only in the voltage class, so the check is done on the full order code and the data sheet table. The route for these checks is on our obsolete part cross reference hub, and the drop in comparison is on pin to pin cross reference.
For volume builds, SUPERB Assembly support covers the heatsink interface, the gate lead routing and the creepage distance the part needs at 600 V.
Q: Can you quote a 600 V 12 A SCR together with the gate resistor and the snubber values for an inductive load?
A: Yes. Send the load type, the line voltage, the RMS current and the gate drive available, and the SUPERB Tech team will confirm the voltage class, the trigger current and the package from the maker data sheet before quoting.
Why Buyers Source Thyristors Through SUPERB
- Voltage class confirmed on the code: the last digits of a thyristor code carry the blocking voltage, so the class is read from the data sheet table and not from the series name before a part is quoted.
- Gate drive matched to the part: trigger current, trigger voltage and holding current are given with the quotation, so the driver stage is sized once instead of being revised after the first prototype.
- Surge figure quoted with the current: the half cycle surge rating is stated next to the RMS current, which is the pair that decides whether the part survives the inrush of a motor or a capacitor bank.
- Discontinued classes tracked: where a voltage class has been dropped from a family, the next class up in the same package is offered with the gate and thermal differences written out.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, Bridge rectifiers and Schottky rectifiers, Solid state relays and photovoltaic drivers, Power MOSFETs for motor drive, TVS and ESD protection diodes, Component lead time solutions.