Contact Us
  • Home
  • COMPONENTS
  • Thermoelectric Coolers and Peltier Modules for Precision Cooling

Thermoelectric Coolers and Peltier Modules for Precision Cooling

A Peltier module moves heat when current flows, and reversing the current moves it the other way. Sub watt modules stabilise laser diodes, photodiodes and crystal oscillators where the load is small and the set point is tight. Larger single stage modules pump 7 W to 53 W for instrument chambers and reagent blocks. Every figure is quoted at a stated hot side temperature, because Qc and delta T both fall as that temperature rises.
quote now

Product Specifications

Product Overview

A thermoelectric module is an array of p and n doped bismuth telluride pellets between two ceramic plates. Current through the pellets carries heat from one plate to the other, so one face cools and the other heats, and the direction reverses when the current reverses. There are no moving parts, no refrigerant and no orientation requirement, and the cold face temperature is set by the current, which is why these parts appear wherever a few watts have to be held at a fixed temperature to a fraction of a degree.

The two numbers that decide whether a module fits are Qc and delta T, and both are only meaningful with a hot side temperature attached. Qc max is the heat pumped when the temperature difference is zero, which is the best case and never the working point. Delta T max is the difference reached when the module pumps no heat at all. In use the module sits somewhere between the two, and the curve that connects them is drawn for a stated hot side temperature, so a module quoted at 27 C delivers less at 50 C and less again at 80 C. The OptoTEC OTX08-08 shows the effect plainly: 0.4 W of Qc at 27 C, 0.5 W at 50 C, with delta T max rising from 72.9 C to 81.8 C over the same range.

Current and voltage are coupled through the module resistance, and that coupling sets the drive electronics. A module rated 6 A and 15.4 V needs a supply that can hold 15.4 V at 6 A, which is 92 W of input for 53 W of pumping, so the heat rejected on the hot side is the sum of both and the heatsink has to be sized for that sum rather than for the load. A small optical module rated 0.8 A and 0.5 V is driven from a low voltage rail with a linear stage, and the same controller can hold a set point to a milli kelvin because the thermal mass it is working against is tiny.

Mechanical assembly decides the life of the part. The pellets are brittle and the solder joints take the full thermal cycling load, so the hot side needs a flat surface, a thin and even layer of thermal compound or a cured pad, and a mounting force that is applied through the ceramic, not through the edge. Bending or clamping the plates will crack pellets, and a module that has been run without a heatsink on the hot side will have exceeded its maximum operating temperature before it failed. The OptoTEC parts are rated to 120 C maximum, and the CUI CP60 series is quoted at 27 C and 50 C hot side, so the derating is part of the selection, not an afterthought.

The table below covers the modules we quote most often: the sub watt optical sizes for laser and photodiode stabilisation, and the 6 A single stage family for instrument and reagent cooling. Qc, Imax, Vmax, delta T max and maximum operating temperature come from the maker data sheet for each part number.

Key Specifications

ParameterOptical size, Laird OTX08-04Optical size, Laird OTX08-08Single stage 6 A, CUI CP60 series
Qc max at 27 C hot side0.22 W0.4 W7.1 W to 53.0 W depending on code
Qc at 50 C hot side0.24 W0.5 W7.9 W to 59.3 W depending on code
Delta T max at Qc = 072.9 C at 27 C, 81.8 C at 50 C72.9 C at 27 C, 81.8 C at 50 C66 C to 68 C at 27 C, 72 C to 75 C at 50 C
Imax0.8 A0.8 A6.0 A
Vmax0.5 V0.9 V to 1.2 V2.1 V to 15.4 V depending on code
Module resistance0.54 ohm at 27 C1.08 ohm at 27 C0.29 ohm to 2.20 ohm depending on code
Maximum operating temperature120 C120 CNot exceeded at the quoted hot side figures
FormSingle stage, ceramic plates, 1.0 gSingle stage, ceramic platesSingle stage, ceramic plates, 6 A rated
LeadsSolid wire, 57 mm, uninsulatedSolid wire, 57 mm, uninsulatedLead wire, polarity marked

Included Models and Order Codes

The table lists the part numbers we quote most often for optical stabilisation and for instrument cooling. Qc, delta T max, Imax, Vmax and resistance come from the maker data sheet for that part number, at the hot side temperature the sheet states. The suffixes on the OptoTEC codes carry the internal solder alloy and the surface finish, so a code that differs after the size field is not the same part.

Part NumberQc max at 27 CImaxVmaxDelta T maxResistanceUse
OTX08-04-F0-0202-GG-W2.250.22 W0.8 A0.5 V72.9 C0.54 ohmLaser diode and photodiode stabilisation
OTX08-08-F0-0303-GG-W2.250.4 W0.8 A0.9 V72.9 C1.08 ohmOptical module and sensor housing
CP601407.1 W6.0 A2.1 V68 C0.29 ohmSmall reagent block
CP6013312.2 W6.0 A3.8 V66 C0.51 ohmInstrument cold plate
CP6024013.0 W6.0 A3.8 V68 C0.53 ohmInstrument cold plate
CP6030154014.5 W6.0 A4.2 V68 C0.57 ohmCompact chiller block
CP6023327.9 W6.0 A8.6 V66 C1.20 ohmAnalyser enclosure
CP6034029.0 W6.0 A8.6 V68 C1.21 ohmAnalyser enclosure
CP6033350.5 W6.0 A15.4 V66 C2.20 ohmLarger cold plate
CP6044053.0 W6.0 A15.4 V68 C2.17 ohmLarger cold plate

Key Features

Qc and delta T always with a hot side figure – a module quoted at 27 C will pump less heat at 50 C, and every line in the table carries the condition so the working point can be read off the curve.

Sub watt sizes for optical loads – the OptoTEC parts pump 0.22 W and 0.4 W, which is the range where a laser diode or a photodiode has to be held at a set point without overshooting on the first pulse.

Six amp family covers 7 W to 53 W – one 6 A drive stage and one controller cover the whole CP60 range, so a product family can reuse the electronics across several cooling capacities.

Reversing current reverses the pump – the same module heats or cools, which is what a set point above and below ambient needs, and no valve or second circuit is involved.

No refrigerant and no orientation – the module works in any mounting attitude and has no gas charge, which suits portable instruments and sealed optical heads.

Resistance published for the drive stage – module resistance and Vmax give the drive voltage and the conduction loss, which is what the controller and the heatsink are sized against.

Applications

These parts are quoted for products that hold a small load at a fixed temperature, typically where:

Laser diode and photodiode stabilisation – the emission wavelength of a laser diode moves with temperature, so a sub watt module under the submount holds the die at a set point and keeps the wavelength on the target.

Optical module and sensor housings – a small module keeps a crystal, a filter or a detector at a constant temperature so the calibration does not have to be repeated as the room changes.

Instrument and reagent cooling – a 6 A module under an aluminium block cools a reagent or a sample to 4 C or holds an analyser at a fixed temperature, with the hot side on a fan cooled heatsink.

The module is bonded to the cold plate and wired to the drive stage on the same board, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that assembly.

Sourcing and Cross-Reference

Selection starts with the heat load and the temperature difference, not with the module. The load is the sum of what has to be removed, what leaks in through the insulation and what the module itself has to move, and the difference is the set point against the hot side temperature that the heatsink can actually hold. A module chosen on Qc max alone will be working at a delta T where it delivers a fraction of that figure.

The second check is the drive and the hot side. Current, voltage and resistance set the supply, and the rejected heat is the pumped heat plus the electrical input, so the heatsink and the fan are sized for that sum. A module that is run with the hot side above its rated temperature will have a shorter life regardless of how well the cold side is controlled, and a module that is clamped unevenly will crack pellets before either limit is reached.

Where a part number is short, or where the exact code is no longer offered, the replacement is checked on Qc at the working hot side, Imax, Vmax, delta T max, footprint and thickness at once. A module that matches the footprint but is 0.5 mm thicker will not close the gap in an existing assembly, and a module that matches Qc but needs twice the current will not run on the existing controller. The route for that check is on our source obsolete components page, and the mechanical comparison is on pin to pin cross reference.

For volume builds, SUPERB Assembly support covers the thermal interface layer, the mounting force through the ceramic and the lead dress that keeps the module from being strained at the joint.

Q: Can you quote the OptoTEC module with the same footprint but 0.4 W of Qc, and confirm the hot side temperature the figures are quoted at?

A: Yes. Send the heat load, the set point, the hot side temperature and the space under the plate, and the SUPERB Tech team will match the module and the controller from the maker data sheet before quoting.

Why Buyers Source Peltier Modules Through SUPERB

  1. Every figure carries its hot side temperature: Qc and delta T are quoted at 27 C and 50 C where the sheet gives both, so the working point is not read from a best case number.
  2. Drive conditions stated: Imax, Vmax and resistance are given together, because the controller, the supply and the heatsink are all sized from that set.
  3. Optical sizes stocked as a family: sub watt codes with the same footprint and different Qc are quoted side by side, so a thermal margin can be added without a board change.
  4. Assembly guidance included: flatness, mounting force and interface thickness are part of the quotation notes, because those are what a cracked module traces back to.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, TEC controller chips, IGBTs and SiC power devices, Laser diodes and VCSEL emitters, VCXO and OCXO modules, Sourcing obsolete components, Component lead time solutions.