Contact Us
  • Home
  • COMPONENTS
  • Thermal Fuses and Temperature Cutoffs for Battery and Heater Safety

Thermal Fuses and Temperature Cutoffs for Battery and Heater Safety

Axial one shot cutoffs cover 72 C to 240 C, with 10 A, 15 A and 25 A ratings at 250 VAC. The opening temperature is not the number printed in the code, so the table lists the tested value for each order code. Holding temperature and maximum overshoot are listed as well, because those set the margin in normal operation. Surface mount protectors add a heater terminal for an active cutoff inside a lithium pack.
quote now

Product Specifications

Product Overview

A thermal fuse is a one shot device that opens the circuit when its body reaches a set temperature. Inside the metal case a pellet or a fusible alloy holds a spring loaded contact closed, and when the pellet melts the spring pulls the contact apart and the circuit stays open for good. There is no reset, no holding current and no control input, which is exactly why the part is used as the last line of defence behind a thermostat or a controller: nothing in the firmware can keep it closed once the temperature is reached.

The temperature that matters is measured at the case, not in the air. A part rated to open at 98 C will open when its body reaches 98 C, and the body is heated by three sources at once: the ambient air, the heat conducted along its leads from the board or the winding it protects, and its own I squared R loss. A 10 A fuse with 10 milliohms of resistance dissipates 1 W at rated current, which on a short lead raises the case well above the surrounding air. That is why the data sheet gives a holding temperature next to the opening temperature, and why the part is never operated close to its opening point.

Two mechanical forms cover most of the work. The axial part is a small cylinder with two tinned leads that is crimped, welded or soldered into a harness, a transformer winding or a heater lead. The MICROTEMP G4 and G8 bodies are 14.7 mm long and 4.0 mm across, the SEFUSE SF/R body is 4 mm by 8.5 mm, and the smaller body responds faster because it has less mass to heat. The surface mount protector, such as the Dexerials SFH line, adds a third terminal: a heater resistor that the protection circuit can energise to blow the fuse on command, which is how a lithium pack cuts itself off on an overcurrent that the current alone would not clear.

Choosing the temperature is a margin exercise, not a lookup. The opening point has to sit above every normal operating condition, including a hot day, a blocked filter and the self heating at full load, and below the temperature at which the cell, the winding or the plastic begins to degrade. A common rule is to keep continuous operation at least 25 C below the opening point, and to check that the overshoot temperature the part can survive is above the worst case the neighbouring components can produce. Two parts with the same opening point but different holding temperatures are therefore not interchangeable.

The table below covers the three groups we quote most often: the 15 A SEFUSE axial series for appliances and heaters, the 10 A MICROTEMP G4 for control boards and small appliances, and the 25 A MICROTEMP G8 for higher current loads. Rated current, opening temperature, holding temperature and body size come from the maker data sheet for each order code.

Key Specifications

Parameter15 A axial, SEFUSE SF/R10 A axial, MICROTEMP G4A25 A axial, MICROTEMP G8A
Rated current at 250 VAC15 A10 A resistive, 8 A inductive25 A at 250 VAC, 20 A at 277 VAC
Other ratings10 A version in the same series15 A at 120 VAC, 5 A at 24 VDC25 A at 250 VAC on UL, VDE, CCC and PSE
Opening temperature range73 C to 240 C72 C to 257 C77 C to 240 C
Tolerance on openingTested value stated per code+0 / -5 C+0 / -5 C
Holding temperature68 C to 235 C, stated per code57 C to 220 C, stated per code62 C to 200 C, stated per code
Maximum overshoot after openingNot quoted on the short form sheet100 C to 470 C, stated per code200 C to 470 C, stated per code
Body4 mm by 8.5 mm14.7 mm by 4.0 mm14.7 mm by 4.0 mm
TerminalsAxial leads, tinnedAxial leads, 1.0 mm tinned copper, 63.8 mm overallAxial leads, 1.0 mm tinned copper, 63.8 mm overall
AgencyUL, VDE, CCC and PSE by seriesUL, CSA, VDE, CCC, PSE, KoreaUL, VDE, CCC, PSE, Korea
MountCrimp, weld or solder in a harnessCrimp, weld or solder, 34.9 mm case leadCrimp, weld or solder, 34.9 mm case lead

Included Models and Order Codes

The table lists the order codes we quote most often for battery packs, heaters and appliance harnesses. Rated current, opening temperature, holding temperature and body size come from the maker data sheet for that code. The MICROTEMP codes carry the opening temperature in the part number, while the SEFUSE codes carry a nominal figure that is one to three degrees below the tested opening point, so the two families are read from the table and never from the code alone.

Part NumberRated CurrentOpening TemperatureHolding TemperatureBody
SF70R015 A at 250 VAC73 C68 C to 72 C4 mm by 8.5 mm
SF81R015 A at 250 VAC84 C80 C to 84 C4 mm by 8.5 mm
SF94R015 A at 250 VAC99 C92 C to 96 C4 mm by 8.5 mm
SF113R015 A at 250 VAC113 C106 C to 110 C4 mm by 8.5 mm
SF139R015 A at 250 VAC142 C137 C to 141 C4 mm by 8.5 mm
SF167R015 A at 250 VAC167 C162 C to 166 C4 mm by 8.5 mm
SF214R015 A at 250 VAC216 C211 C to 215 C4 mm by 8.5 mm
G4A00072C10 A at 250 VAC72 C57 C14.7 mm by 4.0 mm
G4A00084C10 A at 250 VAC84 C69 C14.7 mm by 4.0 mm
G4A00098C10 A at 250 VAC98 C83 C14.7 mm by 4.0 mm
G4A00110C10 A at 250 VAC110 C95 C14.7 mm by 4.0 mm
G4A00121C10 A at 250 VAC121 C106 C14.7 mm by 4.0 mm
G8A00077C25 A at 250 VAC77 C62 C14.7 mm by 4.0 mm
G8A00084C25 A at 250 VAC84 C69 C14.7 mm by 4.0 mm
G8A00098C25 A at 250 VAC98 C83 C14.7 mm by 4.0 mm

Key Features

One shot by construction – the contact is held closed by a pellet or an alloy that melts at the rated point, so the circuit opens once and stays open, and the part has to be replaced before the product can run again.

Opening and holding temperature are different figures – the opening point is where the part trips and the holding temperature is the highest value it survives for 168 hours without tripping, which is why continuous operation is kept at least 25 C below the opening point.

Self heating counts against the margin – a 10 A part with 10 milliohms of resistance dissipates 1 W and a 25 A part with the same resistance dissipates 6.25 W, so the case runs hotter than the air and the lead length becomes part of the thermal calculation.

Small body, fast response – the 4 mm by 8.5 mm SEFUSE body heats through faster than the 14.7 mm MICROTEMP case, which matters where the part is wrapped in a winding or potted into a heater block rather than mounted in free air.

Voltage derating is stated per agency – the G4A is 10 A at 250 VAC but 15 A at 120 VAC and 8 A on an inductive load, so the current on the label is not the current the part can break in every circuit.

Surface mount with a heater terminal – the SFH 30 A protector is 5.4 mm by 3.2 mm by 1.25 mm with 1.3 milliohms of resistance, breaks 80 A at 62 VDC and takes a 260 C reflow profile, and its heater terminal lets the protection circuit trip it on command.

Applications

These parts are quoted for products where an overheating condition has to be cut off without software, typically where:

Lithium pack secondary protection – a cutoff sits in series with the cell string behind the protection board, and the surface mount heater version trips on an overcurrent that the board cannot clear by itself.

Heaters, fans and small appliances – an axial part is crimped into the supply lead next to the element or the motor, so a seized fan or a blocked air path opens the circuit before the plastic housing reaches its limit.

Transformer and motor winding protection – a part buried against the winding opens when the winding runs hot from an overload or a shorted turn, which is the case a current fuse on the primary does not always catch.

The cutoff is fitted into the harness that mates with the control board, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.

Sourcing and Cross-Reference

Selection starts from the temperature, not from the current. The opening point is set by the hottest normal condition plus the margin, the holding temperature has to be above that same condition, and the rated current has to cover the load at the voltage the circuit actually breaks. A part that is right on current but too close on temperature will trip on a hot day, and a part that is right on temperature but rated at 10 A in a 16 A circuit may not open cleanly at all.

The second check is the thermal path. A cutoff that sits in free air sees the ambient temperature, one that is taped to a cell sees the cell temperature, and one that is potted sees the potting temperature, and the same part gives three different trip times in those three positions. The maker data sheet quotes the opening point on a defined test fixture, so the first prototype is where the mounting is proven, not the catalogue.

Thermal fuses are also one of the most copied components in the market, and a re marked part with a 130 C pellet sold as a 98 C part defeats the whole function without any visible sign. Lots are checked on marking, body dimensions, lead material and a sample trip test before they are offered. The checking route is on our verify original components page, and the alternatives for discontinued temperature points are on source obsolete components.

For volume builds, SUPERB Assembly support covers the crimp or weld to the lead, the sleeving that keeps the body against the cell or the winding, and the pull test on the joint.

Q: Can you quote G4A00098C with the UL and VDE markings shown, and confirm the holding temperature for a 60 C enclosure?

A: Yes. Send the opening temperature, the continuous current, the voltage the circuit breaks and the mounting position, and the SUPERB Tech team will confirm the code and the holding margin from the maker data sheet before quoting.

Why Buyers Source Thermal Cutoffs Through SUPERB

  1. Temperature and current quoted as a pair: the opening point without the rated current says nothing about whether the part opens cleanly, so both are given on the same line with the voltage they apply to.
  2. Holding temperature stated separately: the margin between normal operation and the trip point is the figure that decides whether a product passes a hot soak, and it is quoted rather than left to be inferred.
  3. Body size named for the mounting: 4 mm by 8.5 mm and 14.7 mm by 4.0 mm behave differently in a winding, and the quotation names the body so the harness drawing can be made once.
  4. Provenance checked on every lot: marking, dimensions and a sample trip test are checked before a thermal cutoff lot is offered, because a re marked part looks identical and fails silently.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, Inline fuses and resettable PTC fuses, Varistors and gas discharge tubes, Power and signal relays, TVS and ESD protection diodes, Verifying original components, Sourcing obsolete components.