Inline Fuses and Resettable PTC Fuses for Board Protection
Product Specifications
Product Overview
A fuse and a resettable PTC both open a circuit on overcurrent, and they are not interchangeable. A cartridge fuse melts a metal element and stays open, so it protects against a fault that has to be cleared once and inspected, and it can interrupt 1.5 kA at 250 V without arcing over. A polymeric PTC heats its carbon loaded polymer until the resistance jumps by two or three orders of magnitude, holds the fault current down to a few tens of milliamps, and returns to its low resistance state when the current stops, so it protects a port that a user can fault repeatedly.
That difference sets the position on the board. The fuse goes on the mains inlet or on a battery pack, where the available fault current is large and the failure is a one time event. The PTC goes on a USB port, a sensor rail, a motor winding or a remote feed, where the fault may be a shorted cable that someone unplugs and the board has to work again afterwards. A PTC also has a real resistance in normal operation, from 0.015 Ω on a 3 A part to 0.5 Ω on a 0.5 A radial part, so the voltage drop and the self heating are part of the selection and not an afterthought.
Rating a PTC is done at the temperature the board runs at, not at 20 C. The hold current falls with ambient, and the maker tables show the derating directly: an RXEF050 holds 0.50 A at 20 C and 0.20 A at 85 C, so a 0.5 A part used at 70 C holds 0.27 A. The trip current is about twice the hold current, and the time to trip depends on the fault current, from 0.1 s on a 1206 part at eight times rated current to 15 s on a radial part at five times rated current.
The parts on this page cover both routes at the current ratings we are asked for most: a 5 x 20 mm ceramic time lag cartridge fuse, an axial PICO very fast fuse for a board that has no holder, and a PTC range in 1206, 1812, 2920 and radial packages from 0.5 A to 3.0 A. Where a board carries a PTC as a resettable element and a fuse as the backup, both are quoted together with the coordination check between them.
Key Specifications
| Parameter | Cartridge fuse, 5 x 20 mm | Axial PICO fuse | Resettable PTC |
|---|---|---|---|
| Operation | melts, one time | melts, one time | heats and resets, repeatable |
| Current range | 125 mA to 5 A in the ratings listed | 5 A, 62 mA to 15 A in the series | 0.5 A to 3.0 A hold |
| Voltage rating | 250 V AC | 125 V AC and 125 V DC | 6 V to 72 V |
| Interrupting rating | 1.5 kA at 250 V AC | 50 A AC, 300 A DC | 40 A to 100 A |
| Speed | time lag, 10 In in 10 ms to 150 ms | very fast, 200 % in 1 s | 0.1 s to 15.6 s at the fault current shown |
| Resistance in circuit | 15.3 mΩ cold | 15.5 mΩ cold | 0.015 Ω to 0.5 Ω initial |
| Package | 5.2 x 20 mm ceramic body, holder mount | 3.18 x 7.10 mm axial, through hole | 1206, 1812, 2920 or radial leaded |
| Operating range | -55 C to 125 C | -55 C to 125 C | -40 C to 85 C |
Included Models and Order Codes
The table lists the part numbers we quote most often, with the figures copied from the maker data sheet. For a PTC the hold current is quoted at 20 C in still air, so the ambient derating table has to be applied before the part is confirmed. For a fuse the breaking capacity is quoted at the rated voltage, and it is the figure that decides whether the part may be used on a mains inlet.
| Part Number | Type | Rating | Voltage | Breaking or Fault Current | Initial Resistance | Package |
|---|---|---|---|---|---|---|
| 0215005.MXP | Cartridge, time lag | 5 A | 250 V AC | 1.5 kA | 15.3 mΩ | 5.2 x 20 mm ceramic |
| 0251005.NRT1L | Axial, very fast | 5 A | 125 V AC and DC | 50 A AC, 300 A DC | 15.5 mΩ | 3.18 x 7.10 mm axial |
| 1206L050YR | PTC | 0.5 A hold, 1.0 A trip | 6 V | 100 A | 0.15 Ω | 1206 |
| 1206L075THYR | PTC | 0.75 A hold, 1.5 A trip | 8 V | 100 A | 0.09 Ω | 1206 |
| 1206L110THYR | PTC | 1.1 A hold, 2.2 A trip | 8 V | 100 A | 0.04 Ω | 1206 |
| 1812L110/16DR | PTC | 1.1 A hold, 1.95 A trip | 16 V | 100 A | 0.06 Ω | 1812 |
| 2920L300DR | PTC | 3.0 A hold, 5.0 A trip | 6 V | 40 A | 0.015 Ω | 2920 |
| RXEF050 | PTC, radial | 0.5 A hold, 1.0 A trip | 72 V | 40 A | 0.50 Ω | Radial, 24 AWG leads |
| RXEF110 | PTC, radial | 1.1 A hold, 2.2 A trip | 72 V | 40 A | 0.15 Ω | Radial, 20 AWG leads |
| RXEF250 | PTC, radial | 2.5 A hold, 5.0 A trip | 72 V | 40 A | 0.05 Ω | Radial, 20 AWG leads |
Key Features
Hold current is given at 20 C – a 0.5 A radial part holds 0.48 A at 25 C, 0.36 A at 50 C and 0.20 A at 85 C, so the part is chosen from the derating table at the ambient the enclosure really reaches.
Trip current is roughly twice the hold – the PTC trips at 1.0 A on a 0.5 A part and at 5.0 A on a 2.5 A part, which is the window that has to sit above the start up surge and below the damage level of the load.
Time to trip depends on the fault – a 1206 part trips in 0.1 s at eight times its hold current, while a radial 2.5 A part takes 15.6 s at five times, so a board that has to survive a long surge needs the slower part.
Breaking capacity decides the position – 1.5 kA at 250 V AC for the ceramic cartridge fuse and 100 A at 6 V for a 1206 PTC are not the same kind of protection, and the fuse is the only one of the two that belongs on a mains inlet.
Cold resistance is a load in the circuit – 0.015 Ω on a 3 A PTC drops 45 mV at 3 A, while 0.50 Ω on a radial 0.5 A part drops 250 mV at its hold current and dissipates 125 mW, which is why the voltage budget is checked with the part.
Resettable means no service call – a PTC on a USB port or a remote sensor feed returns to its low resistance state once the fault is removed, so a shorted cable does not turn into a returned unit.
Applications
These parts are quoted for boards that have to survive a fault without a service call, typically where:
Power inlets and battery packs – a 5 x 20 mm time lag cartridge fuse at 5 A and 250 V handles the inrush of a transformer or a bulk capacitor and interrupts a 1.5 kA fault on the inlet.
USB ports and low voltage rails – a 1206 or 1812 PTC at 0.5 A to 1.1 A protects a 5 V port that a user can short, and it resets when the cable is removed so the port works again.
Industrial sensors and remote feeds – a radial PTC at 72 V and 0.5 A to 2.5 A protects a long sensor run, where a shorted cable pulls the loop down and the fault has to clear without a site visit.
The fuse or PTC sits at the inlet of the same board, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.
Sourcing and Cross-Reference
Selection runs on four numbers. The first is the normal current at the highest ambient, because a PTC has to hold that current without tripping and the derating table decides which rating that is. The second is the surge the load draws at start up, which has to stay under the trip current long enough for the board to come up. The third is the maximum fault current the source can deliver, which has to stay inside the breaking capacity of the fuse or the fault current rating of the PTC. The fourth is the voltage across the part after it opens, because a PTC that has to stand off a 48 V rail is a different part from one on a 5 V rail.
Second sourcing a protection part is mostly a mechanical check. A cartridge fuse is defined by its body size and its opening characteristic, so a 5 x 20 mm time lag part is only replaced by another 5 x 20 mm time lag part with an equal or higher breaking capacity, and a fast acting part never replaces a time lag one on a transformer load. A PTC is defined by hold current, trip current, maximum voltage, initial resistance and package, and a part that matches three of those five will still fail in the field.
Where a protection part has been discontinued, the replacement is confirmed against the derating table and the time current curve rather than against the headline current. The route for these parts is on our BOM shortage recovery page, and the check that keeps a re marked part out of a safety function is on verify original components.
For volume builds, SUPERB Assembly support covers the holder footprint for a cartridge fuse, the lead forming on a radial PTC and the reflow profile the surface mount parts need.
Q: Can you supply a 5 x 20 mm time lag fuse or a resettable PTC that matches the hold current and package on our BOM?
A: Yes. Send the part number with its amp code, the rail voltage, the highest ambient and the fault current the source can deliver, and the SUPERB Tech team will confirm the rating from the derating table before quoting.
Why Buyers Source Protection Parts Through SUPERB
- Rating checked at the real ambient: hold current is taken from the derating table at the enclosure temperature, not from the 20 C figure on the first page of the data sheet.
- Breaking capacity matched to the source: the fault current the supply can deliver is compared with the interrupting rating, which is the step that keeps a small fuse off a mains inlet.
- Opening characteristic kept: a time lag part is replaced by a time lag part, so a transformer or a motor load does not blow the replacement at every start up.
- Holder and package quoted together: the fuse holder, the lead spacing and the reflow profile are given with the part, so the assembly does not need a second sourcing step.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, Varistors and gas discharge tubes, TVS and ESD protection diodes, Power and signal relays, BOM shortage recovery, Component lead time solutions.