Varistors and Gas Discharge Tubes for Surge Protection
Product Specifications
Product Overview
A varistor and a gas discharge tube both protect a line from a surge, and they do it in opposite ways. A metal oxide varistor clamps: its resistance falls as the voltage rises, so it holds the line at a level a few hundred volts above the working voltage and absorbs the surge energy in its own body. A gas discharge tube switches: it stays open until the voltage reaches its sparkover point, then arcs and pulls the line down to about 20 V while the surge current flows through the arc.
That difference decides where each part goes. A varistor responds in nanoseconds and is placed across the line at the connector, but it wears with every surge and its capacitance of a few hundred picofarads loads a signal line. A gas discharge tube handles tens of kiloamps and has less than 1.5 pF of capacitance, so it suits a telecom or antenna line, but it is slower and it can leave a follow current burning after the surge if the source can supply it.
The parts on this page are the two families we quote most often for AC input protection, telecom line protection and industrial interfaces. Disc sizes run from 5 mm to 20 mm with continuous ratings from 11 V to 1100 V RMS, and the tube range runs from 75 V to 1000 V with nominal impulse currents from 5 kA to 20 kA. Where the two are used on the same line, the coordination resistor between them is part of the quotation, because a tube that sparks at 600 V behind a varistor that clamps at 710 V will never fire.
Key Specifications
| Parameter | Metal oxide varistor | Gas discharge tube, 2 electrode |
|---|---|---|
| Working principle | clamps, resistance falls with voltage | switches, arcs above sparkover |
| Response time | under 25 ns | microseconds, plus a short delay |
| Continuous voltage | 11 V to 1100 V RMS | 75 V to 1000 V DC sparkover |
| Surge current | 100 A to 8000 A on 8/20 us | 5 kA to 20 kA on 8/20 us |
| Energy | 0.3 J to 151 J for a 2 ms pulse | quoted as discharge current, not energy |
| Capacitance | 80 pF to 23000 pF at 1 kHz | under 1.5 pF at 1 MHz |
| Wear out | degrades with each surge | life counted in operations, 400 shots or more |
| Best position | across the line at the connector | primary stage on a line with a series resistor |
Included Models and Order Codes
The first table group lists metal oxide varistors, the second lists gas discharge tubes. Continuous voltage, surge current, energy and clamping voltage are copied from the maker data sheet for each part number; where a tube is rated for a single 25 kA event and a repeatable 10 kA, both figures are given.
| Part Number | Type | Working Voltage | Surge Current | Energy or Class | Package |
|---|---|---|---|---|---|
| V275LA20AP | MOV, 14 mm disc | 275 V RMS, 369 V DC | 4500 A, 8/20 us | 75 J, clamp 710 V | Radial, 450 pF |
| V275LA40AP | MOV, 20 mm disc | 275 V RMS, 369 V DC | 6500 A, 8/20 us | 140 J, clamp 710 V | Radial, 900 pF |
| V230LA20AP | MOV, 14 mm disc | 230 V RMS, 300 V DC | 4500 A, 8/20 us | 70 J, clamp 595 V | Radial, 550 pF |
| V320LA20AP | MOV, 14 mm disc | 320 V RMS, 420 V DC | 4500 A, 8/20 us | 80 J, clamp 850 V | Radial, 380 pF |
| V130LA20AP | MOV, 20 mm disc | 130 V RMS, 175 V DC | 6500 A, 8/20 us | 70 J, clamp 340 V | Radial, 1900 pF |
| S14K275 | SIOV, 14 mm disc | 275 V RMS, 350 V DC | 4500 A, 8/20 us | 71 J | Radial, 5 mm pitch |
| S20K275 | SIOV, 20 mm disc | 275 V RMS, 350 V DC | 8000 A, 8/20 us | 151 J | Radial, 7.5 mm pitch |
| S10K275 | SIOV, 10 mm disc | 275 V RMS, 350 V DC | 2500 A, 8/20 us | 43 J | Radial, 5 mm pitch |
| CG2230L | GDT, 2 electrode | 230 V nominal DC sparkover | 20 kA, 8/20 us | holdover 150 V | Leaded ceramic, under 1.5 pF |
| CG2470L | GDT, 2 electrode | 470 V nominal DC sparkover | 20 kA, 8/20 us | holdover 150 V | Leaded ceramic, under 1.5 pF |
| CG2800L | GDT, 2 electrode | 800 V nominal DC sparkover | 20 kA, 8/20 us | holdover 150 V | Leaded ceramic, under 1.5 pF |
| 2027-A-23-SM | GDT, surface mount | 230 V DC sparkover | 25 kA one shot, 10 kA repeat | holdover 135 V | 8 x 6 mm SMD, under 1 pF |
| 2027-A-47-SM | GDT, surface mount | 470 V DC sparkover | 25 kA one shot, 10 kA repeat | holdover 135 V | 8 x 6 mm SMD, under 1 pF |
Key Features
Clamping level quoted at a current – a 275 V varistor clamps at 710 V when 50 A flows through it, and the same part clamps higher at a higher current, so the level that matters is the one at the surge current of the application.
Energy rating in joules – the 14 mm disc holds 71 J to 75 J for a 2 ms pulse while the 20 mm disc holds 140 J to 151 J, and the disc size is what carries the energy, not the voltage rating.
Capacitance that loads the line – a 275 V disc has 450 pF, which is invisible on an AC input but shorts a 100 MHz signal, which is where a tube at under 1.5 pF takes over.
Tube sparkover spread – a 230 V tube sparks between 195 V and 265 V on a slow ramp and at 600 V on a 100 V/us front, and this spread is what the coordination with the varistor has to cover.
Follow current and holdover – a tube that has fired stays conducting while the line can supply the arc, and the holdover figure of 135 V to 150 V states the voltage below which it clears again.
Surface mount tubes for automated lines – the 8 x 6 mm SMD tube has the same 10 kA repeat rating as the leaded part and is placed and reflowed with the rest of the board.
Applications
These devices are quoted for lines that leave the enclosure or sit near a connector, typically where: The protection parts sit at the connector of the board, so they are quoted together with the SUPERB PCB and the SUPERB PCBA build that places them.
AC input of a power supply – a 275 V varistor across the line after the fuse absorbs the ring from a lightning strike on the mains, and the fuse is chosen so the varistor does not fail short without clearing it.
Telecom and data line protection – a 230 V tube at the connector takes the bulk of a surge at 20 kA with under 1.5 pF of loading, and a varistor or a TVS behind the series resistor clamps the residual.
Industrial control interfaces – a 14 mm varistor on a 24 V or 230 V field wiring terminal limits the inductive kick from a contactor coil and the surge coupled onto a long cable run.
Sourcing and Cross-Reference
The two parts are quoted as a pair, because the numbers that make one work can make the other useless. A varistor that clamps at 710 V in front of a tube that sparks at 600 V keeps the tube from ever firing, and a tube behind a varistor with no series resistance lets the varistor take the full 20 kA. The working method is to fix the clamping level the downstream circuit survives, then pick the varistor voltage above the highest steady line voltage, then check that the tube sparkover sits above the varistor clamp.
The second check is the wear budget. A varistor degrades a little with every surge and fails short at the end of its life, so the energy rating is compared with the surge the line actually sees and the fuse is chosen to clear a shorted disc. A tube is counted in operations: 400 shots at 500 A on a 10/1000 us wave, 10 shots at 10 kA on an 8/20 us wave, and the surface mount part holds a single 25 kA event.
Where a disc size or a voltage has gone end of life, the replacement has to match the clamping voltage at the same current, the energy rating and the lead spacing on the board. The route for these parts is on our obsolete part cross reference hub, and the timing question for a line that is still in production is on component lead time solutions.
For volume builds, SUPERB Assembly support covers the disc lead forming, the tube placement and the clearance distance the standard asks for between the protection part and the neighbouring tracks.
Q: Can you supply a varistor and a tube as a matched pair for a line that has to pass a 6 kV surge test?
A: Yes. Send the line voltage, the surge waveform and level, the clamping voltage the circuit survives and the footprint, and the SUPERB Tech team will quote the pair with the coordination resistor value between them.
Why Buyers Source Surge Protection Through SUPERB
- Clamp level matched to the circuit: candidates are filtered on the clamping voltage at the surge current of the application, so a part that fits the footprint but lets 900 V through is dropped early.
- Varistor and tube coordinated: the sparkover of the tube is compared with the clamp of the varistor and the series resistance between them, which is the step most bills of materials leave out.
- Energy and operations counted: the joule rating and the shot count are compared with the surge the line sees in service, so the part is not chosen on voltage alone.
- Footprint and clearance checked: lead spacing, disc diameter and the creepage distance to the neighbouring track are checked before the part is quoted.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, TVS and ESD protection diodes, Bridge rectifiers and Schottky diodes, Obsolete part cross reference hub.