Power Relays and Signal Relays for Load Switching
Product Specifications
Product Overview
A relay is still the only switch that gives a full galvanic gap between the coil and the contact, and that is why it survives in boards that could use a MOSFET or a solid state relay. The price is coil power, a mechanical life counted in operations, and a contact that wears with the load it switches. The three families on this page cover that range: a 10 A to 12 A power relay in a sugar cube case, a signal relay with a 100 mW to 150 mW coil, and a reed relay for dry circuit and high speed switching.
The figure that decides between two relays of the same rating is the load, not the current. A 10 A relay rated for a resistive load at 250 V AC will not carry the same 10 A into a motor, a lamp or a capacitive load, and the data sheet gives a separate rating for an inductive load at a power factor of 0.4. The second figure is the coil: a 400 mW coil at 12 V needs 33 mA of drive, which a small driver transistor supplies, while a 100 mW coil at 12 V needs 8 mA and can be driven from a port pin through a resistor.
Sealing matters as much as the rating. A flux tight relay can be wave soldered and cleaned with a permitted process, a fully sealed relay can be washed and potted, and an unsealed relay traps flux on the contacts and fails after a few thousand operations. Every part in the table is listed with its case and its sealing class, because a relay that fits the footprint but is not sealed the same way will not survive the same board process.
Key Specifications
| Parameter | Power relay, sugar cube | Signal relay, low profile | Reed relay, SIP |
|---|---|---|---|
| Contact rating | 10 A at 250 V AC, 8 A at 30 V DC | 1 A at 30 V DC, 0.3 A at 125 V AC | 0.5 A, 200 V max |
| Max switching voltage | 250 V AC, 125 V DC | 125 V AC, 60 V DC | 200 V AC or DC |
| Coil power | 360 mW to 530 mW | 100 mW to 150 mW | 50 mW at 5 V |
| Coil resistance at 12 V | 275 Ω to 400 Ω | 960 Ω to 1028 Ω | 1000 Ω at 12 V |
| Contact resistance | 100 mΩ max, 30 mΩ on some types | 100 mΩ max | 0.2 Ω max |
| Operate time | 10 ms to 15 ms | 3 ms to 5 ms | 0.5 ms |
| Mechanical life | 10 million operations | 5 million operations | quoted per load |
| Sealing | flux tight or fully sealed | fully sealed | hermetically sealed contacts |
Included Models and Order Codes
The table lists the relays we quote most often. Contact ratings, coil resistance, must operate voltage and contact resistance are copied from the maker data sheet for each part number, with the coil voltage stated in the part number because the same family is offered at 3 V to 48 V.
| Part Number | Contact Form | Contact Rating | Coil | Operate Time | Case |
|---|---|---|---|---|---|
| G5LE-1 DC12 | SPDT | 10 A 250 V AC, 8 A 30 V DC | 12 V, 360 Ω, 400 mW | 10 ms max | Sugar cube, flux tight |
| G2R-1 DC12 | SPDT | 10 A 250 V AC, 10 A 30 V DC | 12 V, 275 Ω, 530 mW | 15 ms max | PCB mount, sealed |
| G2RL-1 DC12 | SPDT | 12 A 250 V AC | 12 V, 360 Ω, 400 mW | 15 ms max | Low profile, flux tight |
| G5V-1 DC12 | SPDT | 1 A 24 V DC, 0.5 A 125 V AC | 12 V, 960 Ω, 150 mW | 5 ms max | Fully sealed |
| G6K-2F-Y DC12 | DPDT | 1 A 30 V DC, 0.3 A 125 V AC | 12 V, 1028 Ω, 100 mW | 3 ms max | SMD, 10 x 6.5 x 5.2 mm |
| 9007-05-01 | SPST-NO reed | 0.5 A, 200 V max | 5 V, 500 Ω, 10 mA | 0.5 ms max | SIP, diode fitted |
Key Features
Galvanic gap between coil and contact – the 2 kV AC dielectric strength between coil and contact on the power relay is the reason a relay is still used where a semiconductor switch would not give the isolation the standard asks for.
Coil power that fits the driver – 400 mW at 12 V is 33 mA, which a small transistor drives directly, while the 100 mW signal relay draws 8 mA and can be driven from a logic output.
Contact resistance at the low end – 100 mΩ max on the signal relays and 30 mΩ on some power types sets the voltage drop in a low level circuit, where a worn contact shows up as a measurement error.
Sealing matched to the process – a flux tight part is wave solderable, a fully sealed part can be washed, and a reed relay has its contacts sealed inside a glass tube so the environment never reaches them.
Bounce and operate time – 3 ms to 5 ms on the signal relays and 0.5 ms on the reed relay, which decides whether the switch can be used for a signal path that is sampled every few milliseconds.
Mechanical life in operations – 10 million operations on the power relay and 5 million on the signal relay, with the electrical life at rated load given separately because the contact wears faster under load.
Applications
These relays are quoted where a board has to switch a load or isolate a circuit, typically where: The relay sits next to the connector and the driver transistor, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.
Mains load on an industrial controller – a 10 A to 12 A relay switches a pump, a heater or a contactor coil from a 24 V control board, and the inductive rating at a power factor of 0.4 is the figure used for sizing.
Signal routing in test equipment – a 100 mW DPDT relay with 100 mΩ of contact resistance routes a measurement path, and the low coil power lets a multiplexer board carry dozens of them.
Dry circuit and high speed switching – a reed relay switches a low level signal with 0.5 ms of operate time and no measurable thermal EMF, which suits a scanner or an instrument input.
Sourcing and Cross-Reference
The first question on a relay is what it switches, not what current it carries. A 10 A resistive rating does not transfer to a motor load, a lamp draws ten times its running current at switch on, and a DC load at 30 V arcs longer than an AC load because the arc does not pass through zero. The data sheet gives a separate rating for each of these, and the quotation is built on the one that matches the load.
The second question is the coil and the board process. The coil voltage has to match the rail on the board, the must operate voltage has to be reached at the lowest supply and the coldest temperature, and the sealing class has to match the washing step. A relay that is not sealed the same way as the part it replaces traps flux and fails early, which is why the case and the sealing are quoted with the part.
Where a family has been discontinued, the replacement is checked on contact form, rating, coil voltage and resistance, pin out and height. The route for these parts is on our power management cross reference page, and the timing question for a board that is still in production is on component lead time solutions.
For volume builds, SUPERB Assembly support covers the coil driver, the flyback diode, the contact creepage distance and the washing step the sealing class allows.
Q: Can you supply a 12 V relay that drops into a footprint built for a discontinued sugar cube part?
A: Yes. Send the contact form, the load, the coil voltage, the pin out and the height limit, and the SUPERB Tech team will confirm which relay fits and quote it with the coil data for the rail.
Why Buyers Source Relays Through SUPERB
- Rating matched to the load type: the inductive, lamp and DC ratings are checked against the real load rather than the resistive headline figure.
- Coil checked at the cold rail: must operate voltage is compared with the lowest supply and the coldest temperature, which is where a 12 V relay on an 11 V rail fails to pull in.
- Sealing matched to the process: the washing and coating steps on the board are matched with the sealing class of the part, so flux does not end up on the contacts.
- Footprint and height confirmed: pin out, height and contact clearance are checked against the board before a sample is offered, because sugar cube families differ between makers.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Discrete and power semiconductors, Solid state relays and photovoltaic MOSFET drivers, IGBTs and SiC power devices, Power management cross reference.