Contact Us

HXN50240

Brand: Hisiwell
Hisiwell HXN50240 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN50240 — Discrete & Power Semiconductors | Superb Automation

HXN50240

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN50240 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN50240: two hundred watts across 3 to 4.2 GHz in continuous wave

The HXN50240 is a gallium nitride HEMT from Hisiwell for the 3.0 to 4.2 GHz window, quoted at 200 W on a 28 V rail and stated to deliver more than 250 W at 32 V. The prose says both ports are matched and that the device supports linear and saturated operation as well as continuous wave and pulsed continuous wave. The family index prints 200 W in the peak column with the mode reading continuous wave, and files the part under the unmatched heading.

The band is 1.2 GHz wide, which at a 3.6 GHz centre is 33 per cent, and that is wide for a 200 W device. A single section match does not hold it, so the board carries a multi section or a tapered structure and the loss of that structure is part of the output budget.

Two hundred watts is 53.01 dBm and 250 W is 53.98 dBm. No gain and no efficiency is published. At 45 per cent drain efficiency the DC input is 444.4 W, the current is 15.87 A at 28 V or 13.89 A at 32 V, and the heat is 244.4 W. At 55 per cent it is 363.6 W, 12.99 A at 28 V or 11.36 A at 32 V, and 163.6 W of heat.

Unlike its 2.7 to 3.5 GHz sibling, the index marks this part as continuous wave, so the 164 to 244 W of dissipation is not a pulsed average, it is a continuous figure. That puts the part in liquid cooled territory at the top of its range and in forced air at the bottom, and the difference between those two is decided by the efficiency the factory will not publish.

The parameter rows behind the HXN50240

Part classGallium nitride HEMT, described as matched at both ports and filed in the unmatched table
Frequency range3.0 to 4.2 GHz
Power at 28 V200 W
Power at 32 VMore than 250 W
Power in dBm, calculated53.01 dBm at 200 W and 53.98 dBm at 250 W
Operating mode, index rowContinuous wave
Operating modes, product proseLinear, saturated, continuous wave and pulsed continuous wave
Power gainNot published
Drain efficiencyNot published
DC input at 45 per cent, calculated444.4 W, 15.87 A at 28 V, 13.89 A at 32 V
DC input at 55 per cent, calculated363.6 W, 12.99 A at 28 V, 11.36 A at 32 V
Dissipation at 45 per cent, calculated244.4 W
Dissipation at 55 per cent, calculated163.6 W
Supply rails28 V nominal, 32 V for the higher output
Load voltage at 50 ohm, calculated100.0 V RMS, 141.4 V peak at 200 W
Load voltage at 250 W, calculated111.8 V RMS, 158.1 V peak
Band width, calculated1200 MHz, which is 33 per cent of the centre frequency
Output per GHz of band, calculated167 W per GHz
MatchingStated as matched at both ports in the prose, contrary to the table
Body and packageNot published
Thermal resistance, junction to caseNot published
Pulse width and duty limitsNot published
Gate bias point and quiescent currentNot published
Orderable addendum, marking and packingNot published

Sixteen amps at twenty eight volts and a continuous heat load of one hundred and sixty watts

Continuous wave at 200 W is the hardest reading of this part. The 163.6 W at the optimistic efficiency is still three times what a large finned block holds in free air, so the sink is forced air with a serious fan or a liquid plate. At the pessimistic 244.4 W only a liquid plate closes.

Sixteen amps at 28 V is a bus bar and a choke with a 20 A saturation rating. The bulk bank has to hold the rail through the envelope of the signal, and at 3 to 4.2 GHz the choke has to present a high impedance across a band that spans more than an octave, which means two sections with a capacitor between them and a resonance that sits outside the band.

The 32 V option raises the output above 250 W at 13.9 A, which is the more efficient route to the top of the part on the DC side. It also raises the voltage on every passive in the drain network and on the gate clamp, so the conversion is a re-qualification rather than a tap change.

The output network carries 141.4 V peak at 200 W and about 200 V peak under a two to one mismatch. The series element has to carry the full RF current at that voltage, and the capacitors have to hold their Q at 4 GHz, which limits the choice to porcelain and thin film parts rather than high K ceramics.

HXN50240 against the group and the wideband member

HXN502452.7 to 3.5 GHz200 WNot publishedNot publishedSame power, pulse row
HXN502403 to 4.2 GHz200 WNot publishedNot publishedReference point, CW row
HX2040185F2 to 4 GHz185 W18 dB70 per cent0.34 dB below, publishes gain and efficiency
HX446050F24.4 to 6 GHz50 W15 dB55 per cent6.02 dB below, upper band
HX1020240P21 to 2 GHz280 W20 dB80 per cent1.46 dB above, lower band
HX2580258GX5.2 to 5.9 GHz25 W peak12 dB25 per cent9.03 dB below, upper band

The overlap with the HXN50245 between 3.0 and 3.5 GHz is the interesting row. Both are 200 W on 28 V and both claim 250 W at 32 V, and the only published difference is the mode column, pulse on one and continuous wave on the other. A 3.2 GHz continuous wave product should read the continuous wave row, even though the pulse row may reach a higher peak, because the mode column is the vendor's own statement of how the part was characterised.

Against the HX2040185F the trade is 0.34 dB of output against a published 18 dB of gain and 70 per cent efficiency over a band that starts half a gigahertz lower. For a wideband sweep the published rows are worth more than the third of a decibel.

All four members of the 2.7 to 6 GHz region are on the RF power transistor cross reference, and where a 200 W part has to be substituted by a smaller one, obsolete RF part replacement covers what has to be re-qualified rather than simply swapped.

Board notes for a continuous wave stage at four gigahertz

The sink is the first item. At 164 to 244 W of continuous dissipation the thermal side is not a detail at the end of the project, it is the project. A liquid plate with a flow rate and a coolant temperature is the honest baseline, and an air cooled build has to be justified by a measured case temperature rather than by a simulation.

The match is the second item. A 33 per cent band at 3.6 GHz with 200 W is a multi section structure on a low loss laminate, and the loss of that structure is a tenth of a decibel per element at least. The board material and the copper weight are fixed before the network is tuned, because a change in either retunes the whole match.

The bias is the third item. No gate voltage and no quiescent current is published. A 16 A drain at class AB wants a bias network that holds its current as the case temperature rises, and at 4 GHz the bias choke has to be a low inductance part that does not resonate inside the band.

The fourth item is the mode question. The prose lists linear, saturated, continuous wave and pulsed continuous wave, and the index settles on continuous wave. For a linear application the back off from saturation has to be measured, because no compression point is published and the efficiency at a backed off point is well below the 45 to 55 per cent assumed here.

Questions buyers ask about HXN50240

Is it matched? The prose says both ports are matched and the table files it as unmatched. We quote it as matched on the vendor wording and require written confirmation before a board is cut.

Is it pulse or continuous wave? The index row says continuous wave, which is the harder rating, and the prose lists both. A pulsed application can use the same part, but the continuous wave row is the conservative reading for a continuous application.

What is the gain? Not published. At this power and frequency the drive is a watt or more, so the stage in front is an amplifier with its own heat.

Can it run at 32 V? The vendor states more than 250 W at 32 V. That is a change of rail for the whole network, not just the supply, and it should be treated as a different operating point with its own measurement.

How do we start? Send the band, the rail, the mode, the duty if pulsed, the ambient and the coolant if liquid cooled. We will confirm the match condition and the gain with the factory, quote from the schedule and ship a sample measured at 3.0, 3.6 and 4.2 GHz with the case temperature recorded.