Contact Us

HXN40067

Brand: Hisiwell
Hisiwell HXN40067 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN40067 — Discrete & Power Semiconductors | Superb Automation

HXN40067

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN40067 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN40067: 53 dBm in a 100 microsecond pulse across 5.3 to 5.9 GHz

HXN40067 is the top row of the Hisiwell GaN internally matched family for 5.3 GHz to 5.9 GHz, with 53 dBm of saturated output, 10 dB of gain, 45 percent drain efficiency, a 28 V drain rail, plus or minus 0.8 dB of flatness and a pulse rating of 100 microseconds at 10 percent duty. Both ports are matched to 50 ohm inside the package.

53 dBm is 199.5 W of peak envelope power, the same output as the 4.4 GHz to 5.0 GHz row HXN40053, and the difference between the two parts is the band rather than the power. The mode is the interesting specification: at 10 percent duty the device draws 443.4 W of DC during the pulse, which is 15.8 A from a 28 V rail, and dissipates 243.9 W while the pulse is on, but the average over a pulse train is 44.3 W of DC, 1.58 A and 24.4 W of heat.

The numbers on this page are the vendor rows for the part, and the duty cycle arithmetic is shown because that is what a pulsed transmitter budget turns on. A heatsink sized on the peak would be five times larger than the one the average requires, and a capacitor bank sized on the average would droop during the pulse.

Peak against average: the two numbers a pulse budget needs

During the 100 microsecond pulse the device needs 15.8 A at 28 V. Between pulses it needs almost nothing. The supply that feeds the drain therefore has to deliver 1.58 A on average and the capacitor bank in front of the flange has to supply the difference for 100 microseconds without dropping below the point where the output envelope sags. A 100 microfarad bank with 20 milliohm of equivalent series resistance drops 1.6 V at 15.8 A, which is 5.7 percent of the rail, and that is already a visible change in the pulse top.

The storage capacitance needed for a given droop is simple arithmetic: 15.8 A for 100 microseconds is 1.58 millicoulombs, and holding 1 V of droop across that charge needs 1.58 millifarad. That is a bank of ceramics and one or two polymer parts, placed within 20 mm of the flange, with the supply behind a small series element so the bank is not loaded by the regulator loop. The series element is what keeps the pulse current out of the supply and the supply noise out of the pulse.

FunctionInternally matched GaN power transistor, 50 ohm in and out
Frequency band5.3 GHz to 5.9 GHz
Saturated output power53 dBm, which is 199.5 W peak envelope power
Gain10 dB at saturation
Drain efficiency45 percent at saturation
Drain voltage28 V nominal
Operating modePulse, 100 microseconds, 10 percent duty
DC input during the pulse443.4 W
DC current during the pulse15.8 A
Dissipation during the pulse243.9 W
Average DC input at 10 percent duty44.3 W
Average DC current at 10 percent duty1.58 A
Average dissipation at 10 percent duty24.4 W
Charge per pulse1.58 millicoulombs
Capacitance for 1 V of droop1.58 millifarad across the pulse
Flatness in bandplus or minus 0.8 dB
Bias sequencingGate negative before drain, drain removed before gate
PackageFlange mount, screw fixed
CoolingHeatsink sized on 24.4 W average, pulse rise on the flange mass
Interface50 ohm microstrip launch at both ports

What 53 dBm buys at the antenna

A 199.5 W pulse into a 30 dBi antenna is 83 dBm of effective isotropic radiated power, which is 200 MW of the theoretical figure and about 200 kW in the units radar engineers use. That is the number that decides detection range, and it is why the top row of the ladder exists: 3 dB less at the transmitter is 3 dB less at the target and roughly 19 percent less range on a fourth power law.

The comparison with the continuous wave rows is instructive. HXN40065 gives 50 dBm on a 122.2 W heatsink and HXN40067 gives 53 dBm on a 24.4 W heatsink, because the duty cycle is doing the work. A product that can accept a 100 microsecond pulse therefore gets 3 dB more output with a fifth of the thermal load, which is the whole reason pulsed radar is built the way it is.

Pulse fidelity, droop and the envelope

A 100 microsecond pulse at 10 percent duty has a 900 microsecond gap, and the thermal time constant of the flange is much longer than that, so the junction temperature is nearly constant across the train. The droop within a pulse therefore comes from the capacitor bank and the bias network rather than from heat. A pulse top that sags by 0.5 dB over 100 microseconds is 12.2 percent of power and usually traces to the bank, the series element or the bias feed length.

The rising edge is the other place where a pulsed stage differs. A bias feed that is a quarter wave at the band centre looks like an open circuit to the pulse envelope and can ring with the bank, which shows as an overshoot on the first microsecond. A damping resistor in series with the feed, chosen so that it does not spoil the RF impedance, is the usual fix. We see this on first articles at 5 GHz far more often than a thermal problem.

The 5.3 to 5.9 GHz ladder in one view

PartPsat (dBm)WattsGain (dB)Vd (V)ModeHeat (W)
HXN40061375.011228CW6.1
HXN400624010.001228CW12.2
HXN400634319.951228CW24.4
HXN400644750.121128CW61.3
HXN4006550100.001028CW122.2
HXN4006651125.891032CW153.9
HXN4006753199.531028Pulse 100 us, 10 percent24.4 average

Read down the heat column and the mode column together and the family makes sense: the first six rows are a thermal ladder, and the last row steps off it into a duty cycle. A product that needs 200 W and can pulse buys the last row and a small heatsink; a product that needs 200 W continuous is not served by this family at all and needs combining.

Bias sequencing on a pulsed rail

The gate has to be negative before the drain pulse and the drain has to be removed before the gate on every pulse train, not once at power up. In practice that means the gate supply is permanent and the drain is switched, with a clamp that holds the gate below pinch off when the drain rail is absent. A drain switch that closes before the gate clamp settles puts the device into a 15.8 A conduction state with no current limit, and at 243.9 W of pulse dissipation the die fails within a few pulses.

The drain switch itself is a second thermal problem. A 28 V 20 A switch with 5 milliohm on resistance drops 0.08 V and dissipates 1.26 W during the pulse, which is 0.13 W average, and that is comfortable for a MOSFET in a DPAK. The harder part is the inductance between the bank and the flange, which turns the switch edge into a voltage spike that has to be clamped below the device rating.

How we screen and what we do not claim

Our line runs DC parameters and function, which for this flange means gate threshold, drain to source insulation, the bias network and the flange flatness. The 53 dBm pulse at 5.3 GHz to 5.9 GHz is measured on the customer fixture or at a partner RF laboratory and is not a figure we publish, since a DC screen cannot see a pulse thermal path and only a calibrated bench can say what the pulse top does.

The record is what we control: marking, date code and carrier read at incoming against our incoming inspection plan, and lot history down to a unit serial on our component traceability report. Programs that need the certificate chain for a defense platform start from our defense grade components page, and a second source comparison for this power class is on our RF power transistor cross reference.