HXN40065
Product Specifications
HXN40065
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXN40065 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXN40065: 50 dBm continuous wave at 5.3 to 5.9 GHz
HXN40065 is the 100 W row of the Hisiwell GaN internally matched family for 5.3 GHz to 5.9 GHz, with 10 dB of gain, 45 percent drain efficiency, a 28 V drain rail, plus or minus 0.8 dB of flatness and a continuous wave rating. Both ports are matched to 50 ohm inside the package, which is what makes a 100 W stage buildable on a laminate with a flange, a launch and a bias feed.
50 dBm is 100 W, and at 45 percent efficiency the device draws 222.2 W of DC, which is 7.94 A from a 28 V rail, with 122.2 W of that leaving as heat in the flange. Those figures are the reason this row is a system decision rather than a component decision: a single flange dissipating 122 W needs a cold plate or a heat pipe, and the enclosure, the airflow and the supply all move with it.
The numbers on this page are the vendor table rows for this part, and the derived values are the direct arithmetic from them. The page is written for the engineer who is deciding between one 100 W device and two combined 50 W devices, because that is the decision this row forces and it is not decided by the price of the transistor.
One hundred watts continuous and the coolant question
122.2 W in a flange is past the point where an extruded heatsink in free air is a reasonable answer. A 0.15 degrees per watt cold plate with a 40 degree coolant holds the flange at 58 degrees, which leaves the whole junction to case budget for the die. The same flange on a 1.2 degrees per watt forced air heatsink sits at 171 degrees above ambient, which is not a product, it is a demonstration.
The interface material matters more at this power. A 0.05 mm thermal pad at 0.5 degrees per watt drops 61 degrees across itself at 122 W, which is half the available margin spent in a pad. A thin film of phase change material at 0.1 degrees per watt drops 12 degrees and is the normal choice above 100 W. We ask for the interface and the mounting torque on the purchase order because both change the number the thermal model assumes.
| Function | Internally matched GaN power transistor, 50 ohm in and out |
| Frequency band | 5.3 GHz to 5.9 GHz |
| Saturated output power | 50 dBm, which is 100 W |
| Gain | 10 dB at saturation |
| Drain efficiency | 45 percent at saturation |
| Drain voltage | 28 V nominal |
| DC input at saturation | 222.2 W |
| DC current at saturation | 7.94 A from a 28 V rail |
| Heat in the flange at saturation | 122.2 W continuous |
| Heat with a phase change interface | 12 degrees across a 0.1 degree per watt interface |
| Flatness in band | plus or minus 0.8 dB, which is 20.2 percent of power |
| Operating mode | Continuous wave |
| Input return loss expectation | Set by the internal match, confirm on the data sheet curve |
| Bias feed | Quarter wave at band centre, rated for 8 A |
| Bias sequencing | Gate negative before drain, drain removed before gate |
| Package | Flange mount, screw fixed, cold plate interface |
| Interface | 50 ohm microstrip launch at both ports |
| Cooling | Cold plate or heat pipe sized on 122.2 W continuous |
| Supply | 28 V at 8 A continuous with less than 1 V of droop at the flange |
Combining two 47 dBm parts against one 50 dBm part
Two HXN40064 parts combined through a 90 degree hybrid give 50.12 W plus 50.12 W, less 0.3 dB of combining loss, which is 93.4 W, and they spread 122.6 W of heat across two flanges. The single HXN40065 gives 100 W from one flange at 122.2 W of heat. The electrical result is close; the mechanical result is not. Two flanges are easier to cool with air, harder to fit in a phase array element, and give a graceful failure path if one device dies.
| Arrangement | Output (W) | Heat (W) | Flanges | Failure behaviour |
| One HXN40065 | 100.0 | 122.2 | 1 | Full loss |
| Two HXN40064 hybrid | 93.4 | 122.6 | 2 | Half power, load absorbs the rest |
| Two HXN40063 hybrid | 37.2 | 48.8 | 2 | Half power, load absorbs the rest |
| Four HXN40063 hybrid pairs | 148.7 | 195.2 | 8 | Stepwise reduction |
| One HXN40066 on 32 V | 125.9 | 153.9 | 1 | Full loss |
| One HXN40067 pulsed | 199.5 peak | 24.4 average | 1 | Full loss, pulse duty decides heat |
The table also shows why the pulse row exists. HXN40067 delivers twice the peak power of HXN40065 and dissipates a fifth of the average heat, because the duty cycle is 10 percent. A radar that can live with a 100 microsecond pulse gets 200 W from one flange on a heatsink that a 20 W continuous part would be happy with. A communications link that has to be continuous has no such option and pays the 122 W.
Efficiency at backoff and the supply that follows
Drain efficiency is quoted at saturation, and a real system rarely runs there. At 6 dB of backoff the output is 25 W and the DC input does not fall to a quarter, because the device still draws quiescent current and the efficiency curve falls with it. A conservative planning figure for this class at 6 dB backoff is 25 to 30 percent, which on a 25 W output is 83 to 100 W of DC and 58 to 75 W of heat. A supply sized on the saturated 222 W is correct for the peak and generous for the average, which is the safe direction.
The 28 V rail at 7.94 A has to hold its voltage at the flange through the pulse or the envelope. A switching supply with remote sense at the flange and 10 millifarad of local capacitance holds the rail through a 10 percent load step in about 100 microseconds, which is the timescale that matters for an envelope that changes at the symbol rate. A linear post regulator is the alternative and is 122 W of heat in itself, so most products use the switching supply and accept the switching ripple, which the bias feed filters.
Paralleling, phase and the antenna
Two parts in parallel without a hybrid need matched gain and matched phase, and the vendor table gives gain to the nearest dB rather than as a distribution. In practice a pair is selected on measured gain at the band centre and the phase is trimmed at the input with a line length. That selection is work we can do at incoming when the customer supplies the fixture, and it is the reason a parallel pair is quoted as a matched set rather than as two parts.
What a 100 W stage does to the parts around it
The passive parts near a 100 W flange see field strengths that a 20 W stage never produces. A 0603 capacitor rated for 50 V is fine electrically and still the wrong part if its equivalent series resistance turns the RF current into local heat: at 5.5 GHz, 100 W in a 50 ohm line is 1.41 A of RF current, and a part with 0.1 ohm of equivalent series resistance dissipates 0.2 W in a body the size of a pin head. That is enough to shift the value and, over a long soak, to crack the termination.
The usual answer at this power is a 100 pF or 10 nF single layer ceramic with a broad termination, mounted on the bias feed within 3 mm of the flange, with a second part of a different value beside it to cover the band. The two parts together behave as a low impedance across 5.3 GHz to 5.9 GHz where neither does alone, and they take the pulse current that the supply cannot deliver.
The antenna side at 100 W deserves a circulator. A 10 dB return loss antenna reflects 10 W, which is 8 percent of the heat and a hot spot at the flange edge, and an open connector reflects all of it. A circulator with a load rated for the reflected power is the standard protection and we stock it alongside the transistor, which is covered on our one stop RF supply page.
How this part is screened before it ships
Our line runs DC parameters and function, which for this flange means the gate threshold window, the drain to source insulation, the bias network on the carrier and the interface flatness. Gain and power at 5.3 GHz to 5.9 GHz are measured on the customer fixture or at a partner RF laboratory and are not figures we publish, because a DC screen cannot see a 122 W thermal path and only a calibrated bench can say what happens at the top of the band.
The record is what we control: part marking, date code, carrier and certificate against our incoming inspection plan, and the lot history that follows each serial through our component traceability report. When a customer is deciding between this row and a part from another vendor, the comparison that matters is gain, drain voltage and the thermal resistance of the flange, and that comparison sits on our RF power transistor cross reference.
What to send with an enquiry for HXN40065
Four items turn a quote on this part into an answer: the average output power the system needs rather than the peak, the duty cycle if the traffic is bursty, the rail available on the board, and the airflow or coolant the enclosure can provide. With those we can say whether one 100 W flange is the right answer or whether two 50 W flanges combined will fit the box, and the price difference between those two options is smaller than the mechanical difference.
For a product that is already in production and looking for a second source at this power, the useful comparison is gain, drain voltage and flange thermal resistance, because those three decide whether a part can drop into an existing carrier. That comparison is on our RF power transistor cross reference, and the passives, laminate and connectors that go with a 100 W stage are on our one stop RF supply page.