Contact Us

HXN40036

Brand: Hisiwell
Hisiwell HXN40036 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXN40036 — Discrete & Power Semiconductors | Superb Automation

HXN40036

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXN40036 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXN40036: 316 W at 20 per cent duty over 2.7 to 3.5 GHz

The HXN40036 sits between the 100 W continuous wave part and the 500 W pulsed parts on the same 800 MHz band. It prints at least 55 dBm of saturated output, at least 11 dB of gain, at least 50 per cent typical drain efficiency, a 50 V rail, plus or minus 0.8 dB of flatness and operation in 100 microsecond pulses at 20 per cent duty, in a metal package with 50 ohm ports.

Fifty five dBm is 316.2 W. At 50 per cent efficiency the DC input is 632.5 W and the drain current at 50 V is 12.65 A, so the dissipation during the pulse is 316.2 W. The 20 per cent duty cycle is the highest in this group, which doubles the average load compared with the 10 per cent members: 63.2 W of average dissipation and 2.53 A of average drain current.

Twenty per cent duty at a 100 microsecond pulse means a 500 microsecond period, or 2 kHz repetition, with the device on for a fifth of the time. That is a demanding duty cycle for a package this size, because the average heat is now a real steady state load rather than a rounding error, and the transient excursion during each pulse sits on top of it.

The band is 800 MHz wide, the same window as the continuous wave part, which makes this the natural pulsed upgrade when 100 W is not enough: same band, same port impedance, one rail step from 28 V to 50 V and 5 dB more output.

The parameter rows Hisiwell publishes for HXN40036

Part classGallium nitride power transistor, internally matched
Frequency range2.7 to 3.5 GHz
Saturation output power as publishedat least 55 dBm
Saturation output power in watts, calculated316.2 W
Gain as publishedat least 11 dB
Drain efficiency as publishedat least 50 per cent, typical
Drain voltage50 V
Flatness across the bandplus or minus 0.8 dB
Operating modepulsed, 100 microsecond pulse width at 20 per cent duty
Input impedance50 ohm
Output impedance50 ohm
Output at 1 dB compressionnot published, the index prints a slash
DC input at saturation, calculated632.5 W
Drain current at saturation, calculated12.65 A at 50 V
Dissipation during the pulse, calculated316.2 W
Average dissipation at 20 per cent duty, calculated63.2 W
Average drain current at 20 per cent duty, calculated2.53 A
Drive power for the rated output, calculated44 dBm, 25.1 W
Charge drawn per pulse, calculated1.27 mC
Dissipation if efficiency falls to 45 per cent, calculated386.5 W
Thermal resistance, junction to casenot published
Transient thermal impedancenot published
Package outline and dimensionsnot published in text
Scattering parametersnot published
Pinch off voltage and gate bias pointnot published on this page
Operating and storage temperaturenot published
Moisture level and floor lifenot published
Orderable addendum and packingnot published
Same band, continuous wave, 28 VHXN40035 at 50 dBm
Same band, 48 V, 57.5 dBmHXN42012 at 200 microsecond pulse width

Twenty per cent duty is the thermal decision

The difference between this part and the 10 per cent members of the same band is not the output but the average heat. At 20 per cent duty the average dissipation is 63.2 W against 31.6 W at 10 per cent, and the average drain current 2.53 A against 1.27 A. On a carrier of 0.5 C per watt that is 32 C of average rise over the case rather than 16 C, and that is the number the heatsink lives with hour after hour.

The pulse itself adds an excursion on top, and with no transient thermal impedance published the size of that excursion is unknown. The only defensible method is a measured case temperature at the rated pulse condition on the first article, plus a margin the customer signs off, held against the 75 C case recommendation published in the family's single full data sheet.

Efficiency again moves the answer: at 45 per cent the dissipation rises to 386.5 W in the pulse and 77.3 W on average, at 55 per cent it falls to 258.7 W and 51.7 W. A purchase specification that names the typical figure and receives the floor is asking for 22 per cent more average heat than the cooling was sized for.

The drive chain at 11 dB of gain

Eleven decibels of gain means 25.1 W of drive for 316 W of output, so a driver stage with real power is required. A packaged driver at 30 dBm with 10 dB of gain needs 20 dBm, which is 0.1 W, so the front end of the chain is comfortable; the middle stage is the one that has to produce 44 dBm at 3 GHz with stability into the input of this part.

The input match of the final stage at a backed off drive is not published, so the reflected power from the driver has to be assumed and an isolator allowed for in the chain. At 25 W of drive a 0.5 dB isolator costs 3 W and protects the driver from the load pull of the final stage, which on a wideband internally matched part varies across the 800 MHz window.

Gain flatness is the other unknown. The plus or minus 0.8 dB row is a saturated power figure across the band, while gain against frequency at a fixed drive is a separate curve, and on an 800 MHz band the gain slope is what usually decides whether the system can hold a levelled output without a per channel correction table.

Where a 316 W pulsed stage over 2.7 to 3.5 GHz fits

The fit is a transmitter or a test amplifier that needs a few hundred watts in short pulses across a wide S band window: instrumentation radar, S band datalink transmitters, laboratory amplifiers for high power testing, and phased array element drivers where each element carries a moderate power over a wide band.

It is a poor fit for continuous wave at 316 W, where the 100 W member is the right part, and a poor fit for a long pulse system that keys for a millisecond, because the published condition is 100 microseconds. It is also a poor fit where the driver budget cannot reach 25 W.

Where the requirement is more output on the same band and the same pulse width, the 57.5 dBm part with 13.5 dB of gain delivers 2.5 dB more for the same 25.1 W of drive, which is the cheapest way to gain output in this group. Our RF power transistor cross reference work holds the drive requirement, the duty cycle and the rail of each member so the step can be compared without re-reading four data sheets.

Questions we answer about HXN40036 before a lot is booked

The first is the duty cycle in the real system. Twenty per cent is the published condition and it is also the highest printed in this family, so a system that keys at 30 per cent is outside the data and needs a measured case temperature rather than an estimate.

The second is the driver and the isolator, because 25.1 W into a wideband matched stage is not a comfortable place for a driver without protection.

The third is the lot and the bias. No pinch off voltage and no moisture level are published, so the gate supply is set per lot and established before the drain on every power up, and the quiescent current at that gate voltage is recorded on the first article, and the incoming inspection plan records the marking, the flange and the DC behaviour. A saturated power sweep at 3 GHz belongs on the customer bench or at a partner RF laboratory, and our RF procurement process is where the pulse condition and the cooling interface are agreed with the vendor before the order.